Comparison
Servo vs stepper oz-in ratings: what the number means
Short answer
An oz-in figure on a stepper is holding or low-speed torque that collapses as step rate rises; a servo's rated oz-in holds across its speed range up to rated RPM, with peak typically a multiple of continuous. Compare torque at your operating speed reflected through the gear ratio, not the headline number.

On this page
No. An oz-in figure on a stepper and the same figure on a servo do not describe the same operating point. On a stepper, the headline number is holding or low-speed torque, and it collapses as step rate rises. On a servo, the rated torque holds across the speed range up to rated RPM, and peak torque is a separate, higher figure. So an 80 oz-in servo and an 80 oz-in stepper are not comparable: compare each motor's torque at your operating speed, reflected through the gear ratio to the load.
What the oz-in number means on each motor #
| Quantity | Stepper | Servo |
|---|---|---|
| Torque at low speed | Highest point of the curve; the headline oz-in figure | Roughly equal to the continuous rating |
| Torque at high speed | Falls sharply as step rate rises | Held nearly constant up to rated RPM |
| Rated vs peak | One headline figure; no separate continuous/peak rows | Continuous (rated) row plus a peak row, often around three times continuous |
| Position feedback | Open loop, no encoder required | Encoder, closed loop |
| Where to read it | Torque-speed curve in the datasheet | Continuous and peak rows plus the torque-speed curve |
A low oz-in number on a servo is not a sign of a small motor. Servos are built to turn fast, so modest continuous torque at 4000 RPM becomes large torque at the screw after reduction. That is why the numbers on used listings look wrong: they quote a small figure for a motor that makes its power through speed.
Why the curves diverge #
A stepper winding has inductance, and inductance limits how fast current can change. The electrical time constant is the winding inductance divided by its resistance; as step rate rises, current cannot reach its setpoint within each step period, so torque drops. Back-EMF grows with speed and worsens the shortfall. Lower winding inductance pushes this degradation to higher speeds, which is why the same frame size can show very different curves depending on the winding.
A servo drive closes a current loop around the motor and regulates current against encoder feedback, so the motor holds torque until supply voltage and back-EMF run out near rated RPM. That is the whole difference in one line: the stepper's torque is whatever the physics of its winding allows at that step rate; the servo's torque is actively regulated until the supply cannot push it further.
This decides how gearing behaves. A reduction multiplies torque by the ratio and divides speed by the same ratio, but torque is multiplied only if the motor still has torque at the higher motor speed the reduction forces on it. On a servo, gearing down works exactly as the arithmetic says. On a stepper, it often buys nothing, because the motor was already past the flat part of its curve.
Example: gearing a 275 oz-in stepper against a 100 oz-in servo on a 5 TPI screw #
Inputs (illustrative, typical of datasheet curves — take the real values from the torque-speed curve of the exact motor):
- Stepper: 275 oz-in holds to 1200 RPM, falling to about 100 oz-in at 2000 RPM.
- Servo: 100 oz-in continuous across 0 to 4000 RPM.
- Leadscrew: 5 turns per inch (TPI).
Stepper geared 2:1:
- Screw torque = motor torque × ratio. At the speed the gear forces, the motor must turn 2000 RPM to give 1000 RPM at the screw, where the curve gives its reduced figure.
- Screw torque = 100 oz-in × 2 = 200 oz-in at 1000 screw RPM is the ceiling only if the motor holds it; with the realistic curve sag the usable figure is closer to 50 oz-in at the screw, and screw RPM = 2000 ÷ 2 = 1000 RPM.
- Rapid speed = screw RPM ÷ TPI = 1000 ÷ 5 = 200 IPM, but at about 50 oz-in of torque, which will not sustain a cut.
Servo geared 4:1:
- Motor speed for 1000 screw RPM = 1000 × 4 = 4000 RPM, within its rated range.
- Screw torque = 100 oz-in × 4 = 400 oz-in, available continuously from 0 to 200 IPM.
- Rapid speed = 1000 ÷ 5 = 200 IPM with full torque and fast acceleration.
The decision from these inputs: gearing down the stepper failed because its torque was gone at the speed the gear required; the same reduction strategy on the servo multiplied torque fourfold and kept it across the whole travel range.
Sizing an axis by torque at operating speed #
- Pick the required rapid in IPM and the screw TPI. Required screw RPM = IPM × TPI.
- Choose a reduction ratio so that motor rated RPM ÷ ratio meets or exceeds the required screw RPM.
- Estimate the torque needed at the screw for cutting load plus friction; measure it with a torque wrench or spring scale on the handwheel where you can.
- Divide that screw torque by the ratio to get required motor torque, and check it against the servo's continuous rating at the operating RPM — never against peak.
- Size acceleration against peak torque, and confirm the drive can deliver that peak current and the motor tolerates the resulting duty thermally.
- Confirm the controller's command or pulse rate can reach the rapid; a 25 kHz step rate is a common ceiling to check against.
For a deeper worked current calculation from torque, see How to Calculate Servo Motor Current From Required Torque.
Checks after the first moves #
Run at full rapid and watch following error. A rising error with speed means torque or supply voltage is running out. Run a sustained cut cycle and feel the motor case: heat at continuous load means the load exceeds the continuous rating, whatever the peak says. Command a known distance and verify it with an indicator; closed-loop feedback should repeat to within the backlash of the gear train, so use a low-backlash belt or gear set in the reduction.
Reading used listings without getting fooled #
Used listings routinely quote peak torque, or a figure with no speed attached. Without the continuous rating, the rated RPM and the drive matching (encoder type and voltage differ between drives), the number cannot be sized. If the nameplate is unreadable or no datasheet exists from the manufacturer or its distributors, do not buy on the listing figure alone. And never treat a stepper's 80 oz-in as equal to a servo's 80 oz-in: the stepper's figure exists only at low speed.
Questions asked
Does an 80 oz-in servo equal an 80 oz-in stepper?
No. The stepper's figure is its holding or low-speed maximum, and it falls quickly as step rate rises because winding inductance limits current. The servo's rated torque holds up to its rated RPM, and its peak torque can reach roughly three times the continuous figure. Compare both motors on a torque-speed curve at your operating RPM.
Why doesn't gearing down a stepper multiply its torque like a servo?
A gear reduction multiplies torque only if the motor still produces torque at the higher speed the reduction forces on it. A stepper that holds 275 oz-in to 1200 RPM may drop to about 100 oz-in at 2000 RPM, so a 2:1 reduction yields roughly 50 oz-in at the screw. A servo geared 4:1 keeps its rated torque because it holds torque to 4000 RPM.
Is a servo's rated torque the same as its peak torque?
No. Rated (continuous) torque is what the motor sustains thermally indefinitely, set by winding heat. Peak or intermittent torque is available only for a few seconds, typically for acceleration, and rated torque can be about one third of the peak. Size continuous cutting load against the rated figure and acceleration against the peak.
What if a used servo lists only one torque number with no speed?
That number cannot be sized from. Ask whether it is continuous or peak, and get the rated RPM and the torque-speed curve from the manufacturer or its distributor. Without the continuous rating and rated RPM, an oz-in figure on a used listing tells you almost nothing about performance at your operating speed.
How do I check that my servo axis is sized right after install?
Run a sustained cut and feel the motor case; heat beyond the continuous rating shows the load exceeds it regardless of peak. Command a known distance and verify it with an indicator against the closed-loop feedback.