Sizing an Electric Actuator to Replace a Pneumatic Cylinder

Linear motion, bearings and guides Published 9 min read By AutomateDirectUSA engineering team

Short answer

Size the electric replacement from the measured cold force and the required speed, never from nominal horsepower. At 90 lbf and 0.13 ft/s the ideal duty point is 11.7 ft·lbf/s, or 0.0213 hp, already above a 1/50 hp gearmotor's 0.020 hp before any losses; with drive efficiency and cold-temperature derating plan on roughly 0.05 hp. Choose a screw-driven rod actuator rated for the measured force at that cold temperature, with full-travel stroke and per-direction speed control in the drive.

On this page
  1. Start with the measured cold duty point
  2. Convert the duty point to power
  3. Why the 1/50 hp gearmotor is short
  4. Check the crank option on three numbers
  5. Choose the architecture that fits the control you have
  6. Fix the stroke and the stops before ordering
  7. Give the drive the speeds, duty and holding it must live with
  8. Verify every rating across the whole range
  9. What to hand the supplier
  10. Questions asked

Size the electric replacement from the measured cold force and the speed the test needs, not from the cylinder's bore or a gearmotor's nominal horsepower. Work the numbers for a fixture that pushes a rack at 0.13 ft/s (1.56 in/s) and needs about 90 lbf at -40°C: the ideal mechanical power is 90 lbf × 0.13 ft/s = 11.7 ft·lbf/s, or 0.0213 hp. A 1/50 hp gearmotor is 0.020 hp, short before you count a single loss. Divide by drive efficiency and derate for cold, and the honest motor class lands near 0.05 hp. The right replacement is a screw-driven rod actuator specified on force at speed at that cold limit, with 8 in of usable stroke and per-direction speed control in the drive.

Start with the measured cold duty point #

An air cylinder never tells you the load; it tells you its own bore. Plant air typically reaches the valve at 80 to 100 psi, and an illustrative 1.5 in bore at that pressure pushes with F = p × π/4 × d² = 80 psi × 1.767 in² ≈ 141 lbf, or about 177 lbf at 100 psi. That is why this fixture worked warm and only complained cold: the cylinder had force to spare, and what ran out was flow through the wide-open valves once cold-stiffened lubricant and seals raised the force the rack needed.

So measure, or at minimum carefully estimate, the force at both temperature ends with the real parts installed. In the case this article works through: roughly 90 lbf cold and 36 lbf at 85°C, estimated from the torque of the sixteen parts in the fixture. Those are approximations, so confirm them with a gauge or a pull test at temperature before ordering anything. The cold number sizes the drive; the warm number only sets the duty. Also pin down whether the 0.13 ft/s is an average or a required constant speed, because that single answer accepts or rejects a crank drive.

Convert the duty point to power #

The mechanical power a linear axis must deliver is force times speed in consistent units: P = F × v.

Cold point: P = 90 lbf × 0.13 ft/s = 11.7 ft·lbf/s. One horsepower is 550 ft·lbf/s, so 11.7 ÷ 550 = 0.0213 hp, about 15.9 W. Warm point: P = 36 lbf × 0.13 ft/s = 4.68 ft·lbf/s ÷ 550 = 0.00851 hp. These are calculated examples for those inputs, not measured motor power. It is the same multiply-and-check used when sizing a long-stroke linear actuator for a 500 N push, and it is the first number any actuator supplier will ask for.

The cold point is 2.5 times the warm one (90 ÷ 36), so size everything to cold and let the warm point fall where it falls.

Why the 1/50 hp gearmotor is short #

1/50 hp is 0.020 hp of motor output against the 0.0213 hp ideal cold requirement, below the line with zero losses counted. Losses are not zero. Take a screw-driven actuator at an assumed 40% drive efficiency, an illustrative input: ball screws and lead screws differ widely, and the number for your exact part comes from its datasheet. Required motor output = 0.0213 ÷ 0.40 = 0.053 hp, roughly 40 W. Add breakaway from static friction and any acceleration, and the honest minimum motor class for this duty is about 0.05 hp, not 0.020 hp.

In practice, stop selecting by horsepower altogether. Packaged actuators are rated by force at a speed at a temperature. Specify continuous force at or above the measured 90 lbf with margin, delivered at 1.56 in/s or better, valid at the cold limit. A common rule of thumb is 20 to 30% margin on a measured running load: 90 × 1.25 ≈ 113 lbf, so look at the next size above 113 lbf at speed, and check the actuator's intermittent peak rating against the measured breakaway force.

Check the crank option on three numbers #

A right-angle gearmotor turning a crank is attractive because the parts are simple, so check it against stroke, speed and torque before committing:

  • Stroke. A crank of radius r gives 2r of peak-to-peak travel. The proposed 3 in radius gives 6 in, which cannot cover the fixture's 8 in maximum travel. Rejected on stroke alone unless the 8 in figure is wrong.
  • Speed. The rack travels 12 in per crank revolution (6 out, 6 back), so a mean speed of 1.56 in/s, or 93.6 in/min, needs 93.6 ÷ 12 = 7.8 rpm. At 240:1 that implies a motor base speed near 7.8 × 240 ≈ 1870 rpm, which you verify against the actual motor, because a ratio only delivers speed through the motor's real base speed. The motion is also sinusoidal, not constant: peak rack speed is π/2 ≈ 1.57 times the mean, about 2.45 in/s here, falling to zero at each end of the stroke.
  • Torque. With the crank arm perpendicular to the rack, torque peaks at no less than F × r = 90 lbf × 3 in = 270 lbf·in, which is 22.5 lbf·ft (about 30.5 N·m), before friction and inertia. At 7.8 rpm, that is a peak mechanical demand of 22.5 lbf·ft × 0.82 rad/s ≈ 18.4 ft·lbf/s = 0.033 hp.

The crank fails this fixture on stroke, and it fails a constant-speed requirement kinematically. Revisit it only if the true stroke requirement is 6 in and a sinusoidal speed profile is acceptable to the test.

Choose the architecture that fits the control you have #

The cylinder was double-acting with a meter-out flow control in each direction, so the operators set two independent travel rates. Whatever replaces it has to deliver powered motion both ways with two set speeds, or the conversion changes the test and not just the actuator.

Option Speed behavior Stroke fit Two-direction control Cold end Verdict for this job
Screw-driven rod actuator, servo or stepper Constant speed at load Specify usable stroke of 8 in or more Yes: two speeds, positions and limits in the drive Specify low-temperature lubricant; verify the rating Closest replacement; select on force at speed at temperature
Belt-driven slider axis Constant, higher speed capability Built to any length Yes Same verification, plus belt and guide ratings at temperature Fits if force is moderate and travel long; confirm force class with the supplier
Gearmotor with crank Sinusoidal, zero at each end Twice the radius: 6 in at a 3 in radius No dwell or per-direction rate control without extra hardware Low-temperature grease as a factory option Rejected here on stroke and speed shape
Keep the cylinder, fix the air Set by flow controls; drops when cold Unchanged Already present Dried air plus heated cylinder jackets Keep when precision and cycle data do not matter

For this fixture the decision is the screw-driven rod actuator: constant speed at load, bidirectional control from the drive, and a stroke you specify rather than inherit from a crank radius.

If the conversion keeps slipping, the pneumatic route has two measures that builders of cold-chamber fixtures report working: dry the air properly so nothing freezes in the valves, and wrap the cylinders with external heating the way pipes are protected from freezing. Both must hold across the whole temperature swing, and the heating must suit the fixture. That path keeps the flow-control speeds you already have; it does not give you positions, programmable speeds or force data.

One safety note before you swap anything: a control-of-hazardous-energy procedure per ANSI/ASSP Z244.1 requires you to isolate every energy source, vent the stored air and lock out before you put a wrench on the cylinder, because a charged double-acting cylinder holds stored energy in both chambers. Revisit the machine's risk assessment (ISO 12100) as well, since the new axis changes how the machine stops and holds.

Fix the stroke and the stops before ordering #

The travel story carries three numbers: 2-3 in of normal working travel, a stated maximum of 8 in, and a later 6 in figure. They cannot all be the requirement. Measure the fixture and resolve it, then order usable stroke for the largest real travel, which is 8 in unless the stops are redesigned. Set the normal 2-3 in window as soft limits in the drive, keep the external hard stops as the physical backup, and leave the actuator's own end-of-travel outside both. Never plan on the actuator's internal limit as the working stop at speed; a unit that cannot reach the full travel also silently caps the fixture the first time someone needs the complete move.

Give the drive the speeds, duty and holding it must live with #

State both directional speeds as requirements, not one number. A 3 in move at 1.56 in/s takes 3 ÷ 1.56 = 1.9 s each way, so out and back is 3.8 s; with a 12 s dwell the cycle is 15.8 s and the duty is 3.8 ÷ 15.8 = 24%. That percentage, computed with your real stroke and dwell, is what the supplier checks against the actuator's thermal duty rating, and test fixtures that run all shift at temperature are exactly where an undersized duty rating bites.

Positioning questions, resolution, repeatability and how the axis holds when de-energized, mirror those in choosing an actuator to compress a small spring precisely: decide them from the test's tolerance, and specify a brake if the axis must hold position with the drive disabled.

Verify every rating across the whole range #

The cold end is what rejects parts. Every element in the chain must be documented to the full -40°C to 85°C swing: motor winding insulation, gearbox and screw lubricant, seals, the encoder and its cable, and the cable jackets back to the drive. Low-temperature grease for a gearbox is a factory option you specify and have confirmed in writing, not a default. The same datasheet discipline that matters when selecting a high-temperature linear actuator for oven belt tracking applies at the cold end: the rating for the exact part, or it does not exist. Before release, run the chosen axis at both temperature limits with the production load and record achieved stroke, both speeds, motor current and actuator temperature over repeated cycles.

What to hand the supplier #

  • Measured force versus position at both temperature ends, including breakaway, with the real parts installed
  • Motion profile: stroke, speed in each direction, acceleration, dwell, cycles per hour and the resulting duty percentage
  • Usable stroke required and the end-stop strategy: soft limits plus external hard stops
  • Mounting geometry and the space envelope on the existing fixture
  • The full temperature range, plus any condensation or icing in the chamber
  • The control system the axis must connect to: I/O, network or drive type

With those numbers the selection becomes a lookup rather than a debate: force at speed at temperature, stroke, duty and range. For the duty point worked here, that is an actuator above 113 lbf at 1.56 in/s rated for the cold limit, with 8 in of usable stroke, and the 1/50 hp gearmotor stays on the shelf.

Questions asked

Will a 1/50 hp gearmotor replace this air cylinder?

No. 1/50 hp is 0.020 hp of motor output against a 0.0213 hp ideal cold requirement at 90 lbf and 0.13 ft/s, and that ideal already excludes screw efficiency, breakaway and cold grease drag. A 3 in crank on the same gearmotor also delivers only 6 in of stroke against 8 in of maximum travel. Select a larger screw-driven actuator on force at speed at temperature instead.

How do I convert force and speed to actuator horsepower?

Multiply force by speed in consistent units and divide by 550: hp equals force in lbf times speed in ft/s, divided by 550. For 90 lbf at 0.13 ft/s, that is 11.7 ft·lbf/s divided by 550, or 0.0213 hp of ideal mechanical power. Then divide by the drive efficiency from the datasheet of the exact actuator and add margin for breakaway and acceleration before choosing a motor.

Why is a crank drive a poor fit for a constant-speed rack?

A crank converts steady rotation into sinusoidal slider motion. Rack speed peaks at about 1.57 times the mean and falls to zero at each end of the stroke, and crank torque peaks at force times radius, which is 270 lbf·in with a 90 lbf load on a 3 in crank. If the test needs a set speed in each direction, use a screw-driven actuator, which holds speed directly.

Can I keep the pneumatic cylinder instead of converting?

Yes, if programmable speeds and positions are not requirements. For cold chambers the two measures that fixture builders report working are properly dried air, so moisture cannot freeze in valves and controls, and external heating wrapped around the cylinders, the way pipes are protected from freezing. Both must perform across the entire temperature range, and the heating must suit the fixture and the test.

What must be rated for the cold end on the electric actuator?

Everything in the load path and the control chain: motor winding insulation, gearbox and screw lubricant, seals, the encoder, and the cables to the drive. Low-temperature lubricant is a factory option you must specify and have confirmed against the datasheet of the exact part; a standard catalog lubricant is not automatically rated that low.

What stroke should I order if normal travel is 2-3 in but the fixture can move 8 in?

Order usable stroke for the full 8 in of mechanical travel unless you redesign the stops, because a shorter unit permanently caps the fixture. Set the normal 2-3 in working window as soft limits in the drive, and keep the external end stops as the physical backup, with the actuator's own limits outside both. Never make the actuator's internal end-of-travel the working stop at speed.

Keep reading

  • Selection guide

    Choosing an Actuator to Compress a Small Spring Precisely

    A 2 lbf (8.90 N) spring over 0.5–0.75 in of travel at 0.025 in steps is a screw problem, not a motor problem: a manual fine-lead screw with a locknut holds the setting with no power. Add a stepper only for remote adjustment, an integrated actuator for automated sequences, or a pneumatic cylinder with an adjustable stop when only endpoint positions matter.

    Motors, gearboxes and drives sizing

  • Selection guide

    Selecting a High-Temperature Linear Actuator for Oven Belt Tracking

    Standard electric linear actuators carry maximum ambient ratings of roughly 60–80 °C, so none of them survives the 250–300 °C inside a conveyor oven. Mount the actuator, its feedback and its drive outside the oven wall and let a heat-resistant mechanical linkage move the belt-tracking roll. Add an insulated, continuously air-purged enclosure only where a stabilized measurement still shows the actuator above its rating.

    Linear motion, bearings and guides

  • Explainer

    Actual volume vs free air displacement in pneumatic actuators

    Actual volume is the physical chamber volume the piston sweeps at working pressure. Free air displacement is that same air restated at atmospheric pressure: multiply the chamber volume by the ratio of absolute working pressure to absolute atmospheric pressure, then by cycle rate for CFM.

    Pneumatics and hydraulics