Actual volume vs free air displacement in pneumatic actuators
Short answer
Actual volume is the physical chamber volume the piston sweeps at working pressure. Free air displacement is that same air restated at atmospheric pressure: multiply the chamber volume by the ratio of absolute working pressure to absolute atmospheric pressure, then by cycle rate for CFM.
On this page
- What each term measures
- The conversion runs on absolute pressure
- Where the chamber volume comes from
- Turning volume per stroke into scfm
- Working a 0.02 m³ chamber at 6 bar gauge out to scfm
- Reading published figures without double counting
- When the arithmetic is right and the cylinder still starves
- Questions asked
Actual volume and free air displacement are the same air on two pressure bases. Actual volume is the physical space the piston sweeps, the chamber volume that fills at working pressure. Free air displacement is that same air restated as the volume it would occupy at atmospheric pressure. The conversion between them is Boyle's law: multiply the chamber volume by absolute working pressure over absolute atmospheric pressure. A chamber filled at a typical shop pressure holds roughly seven times its geometric volume in free air. Free air per stroke times strokes per minute gives the scfm the actuator pulls from the supply.
What each term measures #
Actual volume, also called swept volume or cylinder volume, is pure geometry: bore area times stroke on the cap side, annular area times stroke on the rod side. It is the volume that exists at whatever pressure you feed it, so a figure quoted in cubic inches, cubic centimetres or litres with no pressure reference is a chamber volume. Free air displacement is a bookkeeping convention: the mass of air in that chamber, expressed as the volume the same mass occupies at ambient atmospheric pressure. Compressor, regulator and filter-regulator flow ratings are all stated in free air, so actuator demand has to be brought onto that basis before any comparison means anything. Filling a chamber at a typical working pressure takes a multiple of its geometric volume in supply air, because the supply is metered at atmospheric reference.
The conversion runs on absolute pressure #
At constant temperature, Boyle's law gives P1V1 = P2V2, so the free-air equivalent of a chamber volume is:
V_free = V_actual × (P_abs,working ÷ P_abs,atm)
Every pressure in that ratio is absolute. Add atmospheric pressure to a gauge reading first: add one bar, or 14.7 psi, so the same 87 psig becomes 101.7 psia, giving ratios of 7.0 and 6.92 for the two unit systems, close enough that the one-bar convention is standard practice. Putting the gauge number straight into the ratio is the classic mistake: it understates demand by about one-seventh at a typical working pressure, which spends most of a 20 percent design margin before leaks and line losses take theirs. The constant-temperature assumption is sound for consumption work, because exhaust air rewarms to ambient by the time anything meters it.
Where the chamber volume comes from #
Extension sweeps the full bore and retraction sweeps the annulus. With D the bore, d the rod diameter and L the stroke, all in metres for a result in cubic metres:
V_extension = (π D² ÷ 4) × L V_retraction = (π (D² − d²) ÷ 4) × L
The rod side always takes less air than the cap side for the same stroke, by exactly the rod's share of the bore area. If the datasheet already gives you the actual volume, the stroke has done its job: stroke was only a means of computing swept volume, so with actual volume in hand you need working pressure and cycle rate to reach scfm, not stroke.
Turning volume per stroke into scfm #
Free-air flow is free-air volume per stroke times strokes per minute, added across both directions of every double-acting cylinder and every actuator that moves concurrently. Convert cubic metres per minute to scfm with 1 m³ = 35.3 ft³. The same restatement of a pressurized volume as an atmospheric-equivalent flow is the core of pressure chamber CFM calculations for blower sizing, so the method carries over if the project also needs an air mover. For simple applications, bore, stroke, cycle time and working pressure plus a 20 percent allowance will size the supply; that allowance is a rule of thumb, not a tested margin, and it has to absorb leaks, line losses and simultaneous moves.
Working a 0.02 m³ chamber at 6 bar gauge out to scfm #
Inputs, each with its source:
- Actual volume, cap side: 0.02 m³, the actuator's stated swept volume.
- Working pressure: 6 bar gauge, read at the actuator while it moves.
- Atmospheric pressure: 1 bar absolute, the working convention; the standard atmosphere is 1.013 bar, and that 1 percent sits far inside the allowance.
- Cycle rate: 10 extension strokes per minute, this example's assumed sequence rate, taken from the machine cycle.
- Allowance: 20 percent, rule of thumb.
The rule in words: convert the chamber volume to free air with the absolute-pressure ratio, multiply by the stroke rate, then convert cubic metres to cubic feet.
- Absolute pressure: the gauge input above plus 1 bar = 7 bar absolute.
- Free air per stroke: 0.02 m³ × 7 = 0.14 m³.
- Flow: 0.14 m³ × 10 strokes/min = 1.4 m³/min.
- To scfm: 1.4 × 35.3 = 49.4 scfm.
- With the allowance: 49.4 × 1.2 = 59.3 scfm.
Result: about 49 scfm of free air, 59 scfm with the allowance, a calculated example for these inputs rather than a measured flow. The decision follows: the supply path must deliver 50 scfm at the actuator for the chamber to reach full working pressure on every stroke, so set the regulator, valve and supply against 60 scfm. Delivered flow below about 50 scfm shows up as pressure sagging mid-stroke and the actuator slowing down.
Reading published figures without double counting #
| Datasheet figure | Basis | Action |
|---|---|---|
| in³, cm³ or litres, no reference | Chamber volume at working pressure | Multiply by the absolute-pressure ratio |
| scf or scfm | Free air at a standard reference | Use as given, never correct again |
| Nm³, Nm³/h or normal litres | Free air at a normal reference | Use as given; convert the basis when mixing with scf |
Normal and standard references sit at different temperatures, and the common 0 °C versus 20 °C pair works out to 7 percent on volume for the same mass of air. ISO 8778 defines the reference atmospheres that pneumatic consumption data are stated against, so a rating that names it is on a defined basis. Treat any bare volume as a chamber volume: correcting a figure that is already free air double counts the pressure ratio, and skipping the correction on a true chamber volume undersizes the supply by that same ratio.
When the arithmetic is right and the cylinder still starves #
Correct numbers can still describe a machine that runs out of air. Put the gauge at the actuator and watch it during motion, not at the receiver: pressure that falls while the piston moves points upstream, at supply capacity, regulator setting, valve flow coefficient, line size or leaks. Pressure that holds while the motion is still wrong points at the sequence and the directional side, which is the ground covered in pneumatic valve setup for double-acting grippers. Before fitting any gauge or breaking any fitting, isolate and vent the circuit: a charged cylinder is stored energy, and releasing it is part of lockout under OSHA 1910.147.
Questions asked
If I have the actual volume and the free air displacement, can I calculate CFM without knowing the stroke?
Yes. Stroke is only one way of getting the swept volume, and the actual volume already is the swept volume. Take the actual volume, multiply by your absolute working pressure over absolute atmospheric pressure, multiply again by strokes per minute, and that is free-air CFM. Use the published free air displacement only as a cross-check that you and the supplier are on the same pressure basis.
Why does putting the gauge pressure straight into the pressure ratio give the wrong answer?
Because the ratio needs absolute pressure. Your gauge reading plus one bar of atmosphere gives the absolute figure, so at a six-bar gauge setting the multiplier is seven, not six. Using the gauge number understates demand by about one-seventh at that pressure, which spends most of a 20 percent design margin before leaks and line losses take their share.
Does a double-acting cylinder consume the same air extending and retracting?
No. The rod occupies part of the retracting chamber, so that side sweeps the annular area rather than the full bore and takes proportionally less air. Compute each direction from its own area, convert each to free air at the working pressure, and add both whenever the cycle uses both.
A datasheet already quotes scfm. Do I multiply by the pressure ratio again?
Never. Figures in scf, scfm, Nm3 or normal litres are already referenced to atmospheric conditions, so converting them again double counts the pressure ratio. Only bare chamber volumes, quoted in cubic inches, cubic centimetres or litres with no reference, get multiplied. If scfm and Nm3 figures are mixed in one comparison, bring them to a common reference first, because their base temperatures differ by a few percent.