Selection guide
Stepper or Servo for a 6DOF Arm at 1 mm Over 200 mm
Short answer
Gear a stepper; twenty to thirty kgf·cm is 1.96-2.94 N·m of joint torque, and 1 mm at full reach is a 0.29° joint tolerance — a NEMA 23 stepper behind a 10:1 reduction with 16 microsteps meets both with margin. The real limits are gearbox backlash, which spends the whole tolerance at about 17 arcmin, and printed-link deflection. Fit geared steppers on the gravity joints, smart servos on the wrist, and verify the pull-out torque at speed from the datasheet curve.

On this page
- The two numbers every joint must meet
- Why a geared stepper wins this spec
- Example: sizing a shoulder joint for 1 mm at full reach
- Backlash and printed links spend the tolerance
- Choosing the reduction ratio and its hardware
- Holding torque is not the torque you get at speed
- The wrist joints and the yaw base
- Homing and catching a lost step
- Proving the tolerance on the finished arm
- The per-joint decision
- Questions asked
Gear a stepper and the specification closes. The requested joint rating converts to 2-3 N·m of torque, and 1 mm of tip tolerance at a 200 mm reach is a joint tolerance of about 0.29°, so the motors need torque at low speed and roughly a third of a degree of positioning — not servo-grade control loops. Put a geared stepper on the shoulder and elbow, a geared stepper sized on inertia on the yaw base, and smart serial servos on the wrist. Then spend the remaining effort where the motor cannot help: gearbox backlash, which alone can consume the entire tolerance, and printed-link deflection, which takes most of what is left.
The two numbers every joint must meet #
Convert before comparing motors. Hobby ratings quote kilogram-force centimetres; the conversion is 1 kgf·cm = 0.0980665 N·m, so a 20-30 kgf·cm joint spec is 1.96 N·m at the low end and 2.94 N·m at the high end.
The tolerance converts to an angle the same way. The tip moves 1 mm on the reach radius when the joint turns through atan(1 mm / 200 mm) = 0.286°, which is about 17 arcmin. Gearing, structure and control all spend one budget, and nothing else gets to add error on top.
The spec also hides a distinction between joints. Gravity torque belongs to the shoulder and elbow, which hold the arm's weight and payload horizontally; the yaw base turns about a vertical axis, so it carries inertia and friction instead, and it is sized on acceleration rather than holding torque.
Why a geared stepper wins this spec #
Nothing in the requirement asks for closed-loop control. The speeds are low, the dominant load is steady gravity, and the precision lives in the gearing and the structure. At the top of the range, a joint carrying 2.94 N·m and turning at 60 rpm delivers 2.94 N·m × 6.28 rad/s ≈ 18 W of mechanical power; the problem is torque at walking-pace speeds, which is exactly what a reduction multiplies.
A large-frame stepper can reach the stall-torque range without gearing, but the motor then rides on the arm and its mass loads every joint that carries it — and whether a stepper motor makes a small robot arm more accurate is decided by that trade, not by step count. The joint-by-joint torque logic either way is worked through in stepper vs servo torque for robot joints: what actually decides.
| Approach | How it reaches the joint torque | Positioning behaviour | Verdict for this arm |
|---|---|---|---|
| Large stepper, direct drive | Frame size large enough that stall torque covers the joint | 1.8° full step, microstepped, open loop | Torque yes, but the motor mass rides on the arm and steps are coarse without a reduction |
| Smaller stepper with a 10:1 reduction | Motor torque × ratio × gearbox efficiency | Step angle divided by ratio and microsteps; backlash added | The fit for shoulder and elbow |
| Smart serial servo | Fixed by the actuator, low torque class | Closed loop with a built-in encoder | Wrist joints, not the gravity joints |
| Brushless motor with a separate controller | Needs its own reduction at these speeds | Encoder closed loop, more setup | Only if the build grows into fast dynamics |
Example: sizing a shoulder joint for 1 mm at full reach #
Inputs, with their sources: reach 200 mm and tolerance 1 mm at the tip (the specification); payload 1.0 kg held at full horizontal reach, a typical small printed-arm case; joint speed 40-60 rpm (the specification); reduction 10:1 with 16 microsteps (the design choice under test); gearbox efficiency 80%, assumed for the arithmetic — take the real figure from the gearbox datasheet; full step 1.8° on a standard hybrid stepper.
Gravity torque first: T = m·g·L = 1.0 kg × 9.81 m/s² × 0.20 m = 1.96 N·m. That is exactly the low end of the requested range, so the 30 kgf·cm top end — 2.94 N·m after conversion — is the figure to size against, and the links' own weight fits inside the remainder.
Tolerance: atan(1 mm / 200 mm) = 0.0050 rad = 0.286°.
Resolution: one microstep at the joint is 1.8° / (10 × 16) = 0.01125°, which moves the tip 200 mm × tan(0.01125°) ≈ 0.04 mm. Resolution is not the limiting term.
Motor side: required motor torque = 2.94 N·m / (10 × 0.8) = 0.37 N·m, at a motor speed of 60 rpm × 10 = 600 rpm — 2000 full steps per second.
Decision: pick a motor and supply combination whose documented pull-out torque at 600 rpm is at least twice that 0.37 N·m, so about 0.7 N·m, and a gearbox whose datasheet backlash is at most 10 arcmin, leaving the other 7 arcmin of the 17 arcmin budget for the structure. For these inputs a geared NEMA 23 stepper clears the torque line with margin; the tolerance is decided by the gearbox datasheet and the links.
Backlash and printed links spend the tolerance #
Backlash at the joint maps straight to the tip: at full reach, one arcmin of lost motion moves the tip 0.058 mm. A gearbox near the whole 17 arcmin budget would spend the tolerance before any deflection or control error, which is why the gearbox datasheet backlash figure — not the motor — is the first part to specify. Hold it at or under 10 arcmin and about 7 arcmin remains for the links.
Printed gears are the budget path and they wear: backlash opens over cycles. For the first three joints, metal-gear or purchased precision reducers hold the figure longer; the realistic options are compared in gearbox options for a 3D printed robot arm. On the links themselves, bending stiffness scales with section depth, so deep hollow ribbed sections do more than a stronger filament.
Approach every target from the same direction and keep the train preloaded one way. Backlash then stays out of repeatability even while it remains in absolute accuracy.
Choosing the reduction ratio and its hardware #
The ratio is the single decision that sets torque, resolution and motor speed together, and it also divides the load inertia the motor sees by its square — which is why the geared joint starts and stops its load more easily than the same motor direct. As a rule of thumb, ratios from roughly 8:1 to 15:1 land in the same place once the datasheet numbers are in, provided the pull-out check at the resulting motor speed still clears.
Belt stage or planetary gearbox decides where the backlash comes from; the trade is laid out in belt or gearbox reduction for a stepper robot arm. If the reduction is a belt stage, the driving and driven tooth counts set the ratio when you choose timing pulleys.
Holding torque is not the torque you get at speed #
The figure printed on a stepper is holding torque at standstill. In motion the available torque follows the pull-out curve, and it falls as step rate rises, faster for high-inductance windings; a higher supply voltage into a current-mode driver holds the curve up at speed. Through the reduction, top joint speed means 600 rpm at the motor — 2000 full steps per second — so the curve at that step rate, at your supply voltage, is the number that decides whether the joint holds.
Beyond the pull-out curve the motor skips steps silently: no alarm, no report, position simply wrong from then on. That failure mode is the argument for an output-side encoder or a closed-loop drive on the gravity joints.
The wrist joints and the yaw base #
Joints 4-6 carry little gravity torque at this reach, and smart serial servos with built-in encoders close their own position loops around them; the selection logic is the same as in choosing servo actuators for a six-joint robot arm.
The yaw base carries inertia and friction, not gravity: sum mass × distance² for everything beyond the joint, reflect it through the reduction squared, and size the motor on accelerating that inertia at the tip acceleration you want — the reduction logic of the shoulder without the gravity term. If the project later wants speed or active compliance, sizing BLDC torque and reduction for a robot arm joint is the upgrade path.
Homing and catching a lost step #
A stepper wakes with no position. Fit a homing switch or an absolute reference on every joint before the first powered move; absolute joint encoders for a stepper robot arm without homing removes the homing pass entirely. An open-loop stepper that has skipped holds the wrong pose as confidently as the right one, so on the gravity joints the encoder or closed-loop drive is what turns a silent fault into a detected one.
An unpowered arm with gravity joints falls under its own weight — support the shoulder and keep the reach envelope clear during first powered tests.
Proving the tolerance on the finished arm #
- Clamp a dial indicator on a fixed post against the tip at full reach, payload fitted.
- Command the same target twenty times from one direction: the spread is repeatability.
- Approach from the opposite direction and average both runs: the difference between the averages is the backlash contribution.
- Repeat with and without payload: an offset that grows with load is link deflection.
- Watch for drift that accumulates over cycles and never recovers: that is lost steps, so soften the acceleration ramp, verify the driver current against the motor's rated phase current, and re-check the pull-out margin at speed.
The per-joint decision #
- Shoulder and elbow: NEMA 23 stepper with a 10:1 metal or purchased reduction and 16 microsteps; documented pull-out torque of at least 0.7 N·m at 600 rpm at your supply voltage — twice the required 0.37 N·m from the example — and datasheet backlash at most 10 arcmin; output-side feedback.
- Yaw base: smaller geared stepper sized on inertia and acceleration, homing switch, no gravity term.
- Wrist: smart serial servos with encoders.
- Structure: deep hollow ribbed links, measured backlash on the assembled joints, and the dial-indicator test as the acceptance gate for the tolerance.
Questions asked
Can I drive a gravity joint direct with one big stepper instead of gearing it?
You can, but three things go wrong. A 1.8° full step moves the tip about 6.3 mm at full reach, so positioning depends entirely on microstep increments that the motor datasheet does not guarantee as accuracy. The large frame that covers the stall torque is heavy, and its mass adds gravity torque to every joint that carries it. And the motor then runs at joint speed, where the pull-out curve is at its steepest.
How do I measure backlash on an assembled joint?
Clamp the arm at the test pose, mount a dial indicator against the tip, push the tip sideways with a light known force one way, then the other. The travel between the two readings is the backlash at the tip; divide it by the reach to get the joint angle — at the 200 mm spec, 0.058 mm of tip travel is one arcmin. In service, always approach the working pose from the same direction so the measured backlash never enters the repeat positioning.
Which joints actually need feedback?
The shoulder and elbow. Gravity acts on them constantly, so a skipped step becomes a dropped or drifted pose and nothing reports it; give them closed-loop drives or output-side encoders. The yaw base can stay open-loop if it has a homing switch, because a lost step there costs one re-reference. The wrist smart servos already close their own position loops.
What tip speed does the 40-60 rpm spec produce?
At 60 rpm a joint turns at 6.28 rad/s, so a point 200 mm out on the arm moves about 1.3 m/s; at 40 rpm it is nearer 0.8 m/s. That is quick for a printed arm — quick enough that link flex and vibration show up on the dial indicator. If you do not need it, gear deeper or cap the joint speed in software.
Why is hobby arm torque quoted in kgf·cm?
It is the hobby-servo convention: the torque of a kilogram-force acting on a one-centimetre lever. It survives in arm specifications because listings copy it, but it hides a stall-versus-continuous ambiguity. Convert with 0.0980665 N·m per kgf·cm before comparing motors, and check which of the two the datasheet figure actually is.