Two S7-1200 CPUs or One S7-1500 for Six Stepper Axes
Short answer
Yes: two S7-1200 CPUs provide eight documented 100 kHz PTO channels, two more than six axes need, and one HMI reaches both through separate S7 connections. Choose that pair only for independent axes. If any axes must start together or hold a position relationship, use one S7-1500 with two TM PTO 4 modules so every axis lives in a single controller.

On this page
- How many pulse outputs do six stepper axes need?
- What do two S7-1200 CPUs give you for channel count?
- What does one S7-1500 with TM PTO modules give you?
- Do your six axes need to move together?
- Will the pulse rate carry your fastest axis?
- Can one HMI control both CPUs?
- Which architecture should you buy for six stepper axes?
- What should you verify before the axes run?
- Questions asked
Two S7-1200 CPUs clear the channel count for six stepper axes — the documented generators give the pair eight PTO channels, two of them spare — and one HMI drives both CPUs through two separate S7 connections. Whether that is the right architecture depends on a question the channel count cannot answer: do the six axes move independently, or must some of them start together and hold a relationship while they move? Independent axes split cleanly across two CPUs. Coordinated axes belong on one controller — an S7-1500 with two TM PTO 4 modules. This comparison gives the documented numbers, the pulse-rate check for your mechanics, and the decision for each case.
How many pulse outputs do six stepper axes need? #
Each stepper drive with a pulse-and-direction input consumes one pulse-train channel and one direction output, so six axes need six PTO channels and six direction outputs before anything else in the cabinet gets a share.
PTO — pulse train output — is a counted stream of pulses: position rides on the pulse count, velocity on the rate. PWM — pulse-width modulation — is a duty-cycle signal. On an S7-1200 the same on-board generators do either job; you pick the mode for each channel in device configuration by selecting the CPU and opening Pulse Generator (PTO/PWM). A channel committed to PWM — a heater duty cycle, a drive speed reference — is gone from the PTO budget, so count every PWM load before you count axes.
Read each drive's input mode as well. A drive that takes separate clockwise and counterclockwise pulse trains, instead of one pulse train plus a direction level, consumes two generators, and a six-axis request becomes twelve channels.
What do two S7-1200 CPUs give you for channel count? #
Siemens' TIA Portal documentation for S7-1200 CPUs specifies four PTO outputs at 100 kHz per CPU, with 2 Hz as the lowest frequency each generator can produce, so two CPUs yield eight channels — six assigned, two spare.
The arithmetic is 6 ÷ 4 = 1.5, rounded up to two CPUs, with channels left over for a future axis or a PWM load. The pulses come from hardware generators, so the train keeps streaming between scans. What loads the scan is the motion instructions that update those generators, and stacking all six on one CPU is why a PTO stepper axis inflates S7-1200 cycle time — weigh that when you allocate the axes.
Two hardware conditions apply. PTO requires a transistor-output CPU, the DC-output type; a relay-output version cannot serve as a pulse generator. And the four-channel figure belongs to the CPU family — confirm the pulse-generator count on the data sheet of your exact order number, since output types differ across the range.
What does one S7-1500 with TM PTO modules give you? #
The TM PTO 4 technology module adds four identical PTO channels with 24 V outputs for position and velocity commands to the S7-1500 or ET 200MP system, so six axes take two modules on one CPU.
The rounding matches the CPU pair, and so do the spares. The difference is where the axes live: every pulse channel hangs off a single CPU, so all six axes share one program, one scan and one system clock — the precondition for common starts, gearing and shared trajectories.
Two notes before you commit a fast axis to this hardware. The module's maximum pulse frequency is its own figure — take it from the TM PTO data sheet, not from the S7-1200 number. And because the module is released for the ET 200MP distributed I/O system as well, it can sit in a rack beside the drives instead of in the CPU cabinet, which keeps pulse and direction runs short.
Do your six axes need to move together? #
If any two axes must start in the same instant, share a trajectory, or hold a fixed position relationship, they belong on one CPU; only fully independent axes split cleanly across two S7-1200s.
Two CPUs are two programs on two clocks. Commands crossing between them ride the network and arrive with jitter you do not control, so a start bit sent to both lands at different instants. Even inside one CPU a shared scan cycle is not a shared timebase — same scan does not mean synchronized servo axes — and a second controller only widens that gap.
Concretely: a two-motor gantry, a follower axis tracking a master, cut-to-length — any electronically geared pair vetoes the split. Six feeders, clamps and presses each running their own point-to-point moves do not.
Run the test on paper: list the six axes and mark every pair that must relate while moving. An empty list clears the two-CPU design; one entry moves that group onto a single controller. Independent axes still need cross-CPU handshakes for machine-wide start and stop, but that is command traffic, which the network link carries fine.
Will the pulse rate carry your fastest axis? #
Whether the channel ceiling carries your fastest axis comes down to two numbers you choose: the pulses per motor revolution and the travel per revolution of the mechanics.
Here is a calculated example for fixed inputs, not a measured result. Take a 1.8-degree hybrid stepper, which is 200 full steps per revolution; set the drive's microstepping to 10, giving 2,000 pulses per revolution. Couple it directly to a 5 mm/rev ball screw and demand a top speed of 150 mm/s.
Pulse frequency = speed ÷ travel per revolution × pulses per revolution = 150 mm/s ÷ 5 mm/rev × 2,000 pulses/rev = 30 rev/s × 2,000 pulses/rev = 60,000 pulses/s = 60 kHz.
60 kHz sits under the 100 kHz ceiling with 40 kHz in hand. The same chain gives the ceiling speed: 100,000 pulses/s ÷ 2,000 pulses/rev = 50 rev/s, and 50 rev/s × 5 mm/rev = 250 mm/s — an electronic limit, not a torque claim; the motor's torque-speed curve decides what it can actually push that fast. The 2 Hz floor works out to 0.005 mm/s, so it never constrains a screw axis.
What moves the answer: double the microstepping to 20 and the same 150 mm/s demands 120 kHz — over the ceiling. At a fixed channel rate, resolution and speed trade against each other; take resolution back down or move that axis to a faster pulse source.
Can one HMI control both CPUs? #
Yes — configure two S7 connections in the HMI project, one aimed at each CPU, and bind every tag to the connection that owns its variable; a single panel then runs the whole cell.
The HMI works at the supervisory level: it reads and writes variables, and two connections change nothing about motion timing — that question was settled when you placed the axes. The panel itself is the machine's operator station, and an industrial panel PC fits the role since the display and the computer running the HMI runtime are one unit.
For six similar axes, build one faceplate and reuse it: controlling many motors from one reusable HMI screen passes a connection and a tag prefix into each instance instead of cloning screens six times. Test reads and controlled writes to both CPUs before any screen button is allowed to command motion.
Which architecture should you buy for six stepper axes? #
Buy two S7-1200 CPUs when all six axes make independent point-to-point moves; buy one S7-1500 with two TM PTO 4 modules when any pair must start together or hold a relationship while moving.
| Architecture | Channels for six axes | Where coordination lives | Choose it when |
|---|---|---|---|
| Two S7-1200 CPUs | 8 at 100 kHz, 2 spare | None across CPUs; each CPU owns its axes | Every move is independent point-to-point |
| One S7-1500 with two TM PTO 4 modules | 8, 2 spare; top rate from the module data sheet | One CPU: common clock, common starts | Any pair must start or track together |
| One CPU plus drives that store their own moves | Only streamed axes need PTO | In each drive's stored move | Most axes repeat fixed moves |
Two border cases deserve their own answers. When most moves are fixed and repeated, drives that store their own target take a start command instead of a pulse stream — stepper control from a PLC without onboard pulse outputs — and one CPU plus a few streamed axes covers the cell. If the six axes will grow into blended, interpolated paths, that is where multi-axis servo motion outgrows the PLC and a dedicated motion controller takes the axes while the PLC keeps the sequence logic.
What should you verify before the axes run? #
Before drive power is enabled, walk five checks: channel allocation with no PWM conflict, output voltage against each drive's input, direction sense per axis, the one-CPU-stopped response, and a controlled HMI write to each connection.
- Channel allocation: every axis sits on a configured generator plus a direction output, with no channel double-booked as PWM. Check the pulse generators in device configuration, where they were defined.
- Signal level: 24 V pulse outputs into drive inputs rated for them; where a drive expects 5 V, fit the drive maker's specified series resistor or pick the matching input type.
- Direction sense: jog each axis at low speed and confirm sign and scaling before any move that matters.
- One CPU stopped: with drive outputs inhibited, stop each CPU in turn and confirm the other neither drives mechanics that belong to the stopped half nor continues a move that needs both halves — a cross-CPU permissive should block it.
- HMI writes: a controlled write from the panel reaches only the tag's own CPU.
None of these checks is a safety function: guards, interlocks, the E-stop and the safe stop stay hardwired and validated against the machine's risk assessment — ISO 12100 for the assessment, ISO 13849 for the stop circuit's performance level — on either architecture.
Questions asked
Can the spare channels run PWM loads like a heater or a drive speed reference?
Yes, at a price: the same on-board generators serve PTO and PWM, so every PWM load permanently removes one possible stepper axis from that CPU. Budget all PWM loads on paper before committing the six pulse channels, and remember that only transistor-output CPUs can do either job — a relay-output version supports neither.
Can the two S7-1200 CPUs pass commands and status to each other?
Yes, over the network using the controllers' standard partner communication, and that is the right pipe for handshakes: machine start, axis-ready bits, fault words. What it cannot carry is timing. A start bit crossing that link arrives with network jitter, so treat it strictly as a command channel and never as a way to synchronize two axes.
Does splitting six axes across two CPUs lighten the scan load?
Roughly halves the motion work. Each CPU then executes the instructions for its own three axes instead of six, while the hardware generators stream pulses between scans. On a project where motion instructions already stretch the cycle time, that is a genuine benefit of the split, separate from the channel count.
What does the operator see if one of the two CPUs goes offline?
Tags on the dead connection drop to their substitute values while the other CPU's axes keep running unless you prevent it. Write one alarm per connection, disable the faceplates of the affected half, and program a cross-CPU permissive so a missing partner blocks any move that needs both halves of the machine.