What a High-Torque DC Servo Motor Selection Really Requires
Short answer
200 VDC at 15 A is a 3 kW electrical input ceiling, not a motor rating. For a 1 kW high-torque load, size the motor by continuous torque at your required speed using T = 9550 x P / n, then confirm winding, feedback and drive fit from the nameplate of the exact unit.

On this page
- What does a 200 VDC, 15 A supply actually tell you about the motor?
- How much torque does a 1 kW load actually need?
- Why does a DC servo lose torque as speed rises, and how much voltage headroom do I need?
- What separates continuous torque from peak torque on a DC servo?
- How do I compare candidate motors when the listing gives no real ratings?
- What must the drive and feedback match before you order?
- How do you prove the choice before running production parts?
- So which motor do you buy?
- Questions asked
For the load described in the question, roughly 1 kW of mechanical output on a DC permanent-magnet servo running from up to 200 VDC and 15 A, the selection is decided by continuous torque at your required speed, not by the electrical envelope and not by brand or appearance. Those electrical limits together are only a 3 kW input ceiling; the motor's nameplate continuous torque and speed decide whether it does the job without overheating.
What does a 200 VDC, 15 A supply actually tell you about the motor? #
It tells you the electrical ceiling only: 200 V times 15 A is 3,000 W of input power if both occur together at the same interface, which is an upper bound, not a mechanical rating. Mechanical output is always lower because copper loss, brush and friction losses consume part of it, and neither number says anything about continuous torque.
Treat the two numbers as filters, not as a specification. The motor's rated voltage must sit within the drive's DC output range so there is voltage headroom at top speed, and the drive's continuous current must cover the armature current your torque demand needs. Whether the 15 A figure means motor armature current or supply current matters: a switching servo amplifier can draw a different average current from the supply than circulates in the winding, so applying a supply-side limit directly as a torque limit mis-sizes the axis.
How much torque does a 1 kW load actually need? #
Torque depends on speed, and the conversion is T = 9550 x P / n, with T in newton-metres, P in kilowatts and n in rpm. Run the arithmetic for your operating point before you shop:
- At 1,500 rpm: T = 9550 x 1 / 1500 = 6.37 N·m.
- At 500 rpm: T = 9550 x 1 / 500 = 19.1 N·m.
- At 3,000 rpm: T = 9550 x 1 / 3000 = 3.18 N·m.
These are calculated examples for exactly 1 kW at those speeds, not measured results. The pattern is the decision: the same shaft power needs three times the torque at one third of the speed, which is what "high torque" really means. At standstill, shaft power is zero even when the axis needs substantial holding torque and draws full current, so a power label alone cannot tell you whether the motor will hold a loaded vertical axis without overheating.
Split the requirement into three parts: continuous running torque, acceleration torque (T = J x alpha, using inertia reflected to the motor shaft), and stationary holding torque. The motor's continuous rating must cover running plus holding; its overload curve must cover acceleration for the permitted duration.
Why does a DC servo lose torque as speed rises, and how much voltage headroom do I need? #
Back EMF rises with speed, and the applied voltage must cover back EMF plus the resistive drop I x R before any current, and therefore any torque, is left. Current capability governs how much torque you have; voltage headroom governs how long you keep it as speed rises.
A worked example with plausible example inputs shows the shape. Take a motor with a torque constant of 0.5 N·m/A and winding resistance of 0.8 ohm, driving the 6.37 N·m needed at 1,500 rpm. Armature current is 6.37 / 0.5 = 12.7 A, the resistive drop is 12.7 x 0.8 = 10.2 V, and winding inductance briefly demands more during current steps. If the motor's back-EMF constant is 0.05 V per rpm, back EMF at 1,500 rpm is 75 V, so the amplifier must deliver at least about 85 V continuously and more transiently. These constants are illustrative: take the real torque constant, resistance and back-EMF constant from the datasheet of the exact motor. A motor whose rated voltage sits far below 200 V still works on such a drive, but it reaches its back-EMF ceiling at a lower speed, and that ceiling, not the drive, then sets top speed.
Our article on servo motor voltage selection, AC or DC for your axis, covers how this headroom decision separates AC and DC candidates.
What separates continuous torque from peak torque on a DC servo? #
Continuous torque is the nameplate number the motor can hold indefinitely within its temperature rise; peak torque is a short-duration overload bounded by the motor's and drive's overload curves. Selection uses the continuous number for running and holding duty and checks peak only against your acceleration demand and its duration.
Winding heat follows I squared x R, so sustained torque heats the copper even when the shaft barely turns, and a holding-load axis can be thermally harder than a spinning one. Evaluate intermittent cycles with the actual current waveform and cycle durations rather than a peak-current figure. A current that is fine for 200 ms can be destructive over a 10-second hold. For how current follows from your torque requirement, our article on calculating servo motor current from required torque shows the arithmetic.
How do I compare candidate motors when the listing gives no real ratings? #
You compare by the nameplate and the manufacturer's motor data for the exact unit, and you keep unidentified motors off the shortlist until they are identified. Legacy permanent-magnet DC servo families, such as the ones commonly found second-hand from retired CNC machines, are legitimate candidates only once the individual unit's winding, continuous current, speed and torque are documented; the manufacturer's motor data sheets, which list rated torque as the nameplate continuous figure, are the reference to request. Nothing about a motor's appearance establishes a rating.
| Selection criterion | What to verify | Where it comes from |
|---|---|---|
| Continuous torque and speed | Covers running plus holding torque at your operating point | Motor nameplate and manufacturer motor data for the exact unit |
| Rated voltage | Sits inside the drive's DC output range with headroom at top speed | Nameplate and drive operating limits |
| Armature current | Continuous and peak definitions match your current waveform | Nameplate, drive current ratings, load calculation |
| Feedback device | Type, interface and polarity supported by the drive | Motor feedback housing and drive manual |
| Mechanical fit | Flange, shaft, coupling, brushes and commutator condition | Physical inspection of the unit offered |
| Thermal duty | Current waveform and cycle time within the temperature rise | Load profile calculation, motor thermal data |
For the drive side of a legacy DC motor, our article on replacing drives on old DC servo motors without sizing errors lists the checks that keep the winding and the new amplifier matched.
What must the drive and feedback match before you order? #
Four things: motor type and current regulation the drive supports, the drive's voltage range against the motor's rated voltage, the feedback interface (tachometer, encoder or resolver, and its supply and signal levels), and braking provisions for a decelerating load that returns energy to the drive. An amplifier that can supply the requested current does not make that current thermally acceptable for the winding, so keep drive input limits, drive output limits and motor winding limits as three separate lines on your selection sheet. Verify feedback polarity and mounting before relying on closed-loop motion, since reversed polarity can run a commanded move away from the target.
How do you prove the choice before running production parts? #
Commission with the machine restrained against unintended motion, set current and speed limits from the motor and drive documentation before enabling anything, and check wiring, protective bonding, feedback connections and mechanical freedom with power isolated. Then verify stable controlled motion at low speed under a safe test condition, log armature current through a full production cycle, and confirm the current stays within the continuous rating with the holding segments included. If the logged current exceeds the continuous figure during the holds, the selection is wrong regardless of how the axis feels; add gearing, a larger motor, or a lower holding load before production.
So which motor do you buy? #
Buy the identified motor whose nameplate continuous torque at your speed exceeds the 6.37 N·m (at 1,500 rpm) demand from your own load calculation, whose rated voltage leaves back-EMF headroom inside the 200 V ceiling, whose continuous current fits inside the 15 A armature budget with the drive's definitions confirmed, and whose feedback interfaces with your drive. If a candidate cannot produce its nameplate and motor data sheet, it is not a candidate, whatever its price: the cost of the wrong amplifier, feedback conversion or rebuild erases the saving. Source through the manufacturer or its authorized distributors where possible; where a used legacy unit is the economical path, buy only against documentation and an inspection of brushes, commutator and bearings on the actual unit offered.
Questions asked
Does 200 VDC and 15 A mean the motor is a 3 kW motor?
No. Multiplying the two gives 3,000 W of electrical input if both limits occur at the same interface at the same moment. The mechanical output is lower because of winding, brush and friction losses, and neither number is a continuous torque rating. Read the continuous torque and speed from the motor's nameplate or manufacturer data instead.
How do I identify an unmarked or salvage DC servo motor?
Count commutator segments and brushes to confirm it is a permanent-magnet DC machine, measure winding resistance between armature terminals, then compare the numbers against manufacturer motor data for that frame family. Our article on identifying salvage robot servo motors before drive selection walks through the checks in the order that eliminates the most candidates first.
Why does my DC servo lose torque as speed rises?
Back EMF rises with speed and subtracts from the voltage available to drive current through the winding. Once applied voltage barely exceeds back EMF plus the resistive drop, current and therefore torque fall. More voltage headroom, or a lower-speed operating point through gearing, restores the torque.
Can I size the motor from peak torque in the listing?
No. Peak torque is a short-duration overload bound by the motor's and drive's overload curves, and it says nothing about thermal capacity during sustained running or holding. Your continuous requirement, including holding torque at standstill where shaft power is zero, decides the selection; peak only has to cover acceleration for its permitted duration.