AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Comparison

AC vs DC Servo Motors: What Actually Differs

Motors, gearboxes and drives sizing Published 8 min read By AutomateDirectUSA engineering team

Short answer

A brushed DC servo commutates itself, so torque follows armature polarity and the amplifier only has to control the size and direction of one current. An AC or brushless servo needs the drive to place phase currents against rotor-position feedback, so motor and drive must be selected as one matched system. The article gives the torque and back-EMF arithmetic and a decision for each case.

On this page
  1. What is the actual difference between an AC and a DC servo motor?
  2. Does reversing polarity reverse an AC servo motor?
  3. How does a brushed DC servo turn armature current into torque?
  4. What does an AC servo drive have to know that a DC amplifier does not?
  5. Can a brushless servo drive run a brushed DC motor?
  6. How do brushes, inertia and torque ripple change the choice?
  7. Which servo should you buy for your machine?
  8. Questions asked

A brushed DC servo motor and an AC servo motor differ in one place: where commutation happens. The brushed DC motor switches its own armature current mechanically, with brushes and a commutator, so the amplifier only has to control the size and direction of a single current, and reversing polarity reverses torque. An AC or brushless servo has no commutator, so the drive must place phase currents in three windings against measured rotor position, and the motor and drive have to be selected as one matched system. That single difference drives everything else: drive complexity, feedback requirements, maintenance, rotor inertia and how forgiving a surplus motor is when you pair it with a new amplifier. This article gives the comparison, the torque and voltage arithmetic you can check, and the decision for each case.

What is the actual difference between an AC and a DC servo motor? #

The difference is where commutation happens: a brushed DC servo switches its own armature current mechanically with brushes and a commutator, while an AC or brushless servo depends on the drive to place phase currents against rotor-position feedback from an encoder or resolver. Everything about drive cost, feedback, maintenance and surplus compatibility follows from that one split.

The label "DC servo" is itself ambiguous. It can mean a conventional brushed motor, or a brushless motor fed from a DC bus through an electronic inverter — the second is electronically closer to the AC case than to the first. The comparison in brushed versus brushless servo motors on a brushed DC drive covers that split in detail. For selection, compare the three families like this:

Servo family Commutation Motor leads to the amplifier What the drive must know Main selection constraint
Brushed DC Mechanical, inside the motor Two armature leads Voltage, current, armature inductance, feedback Amplifier bus voltage and current rating
Brushless DC, trapezoidal Electronic, discrete sectors from hall sensors Three phases U, V, W plus hall inputs Hall angle convention and phase order Commutation convention match
Sinusoidal AC servo, synchronous Electronic, continuous three-phase currents against rotor position Three phases U, V, W plus encoder or resolver Rotor electrical angle, winding data, feedback protocol Motor and drive as a matched system

A brushless DC motor can be physically identical to a sinusoidal AC servo; the distinction is the drive's waveform. Trapezoidal commutation energizes two windings at a time, sinusoidal commutation coordinates all three continuously, and that difference shows up as torque ripple and low-speed smoothness.

Does reversing polarity reverse an AC servo motor? #

No. Reversing the supply polarity of an AC servo motor does nothing useful, because the rotor has no commutator and the drive, not the motor, decides which stator winding carries current at any rotor position.

For a brushed permanent-magnet servo on a four-quadrant amplifier, polarity reversal of the armature current reverses torque directly — that is what the commutator is for. On an AC or brushless servo, reversing direction means the drive reverses its rotating field while keeping the phase currents in the correct relationship to rotor position, so direction lives in the drive's commutation logic, not in the wiring order. A positioning AC servo is a synchronous machine, which is also why a plain VFD cannot run it: a VFD commands a frequency, but the servo drive needs to know where the rotor actually is.

How does a brushed DC servo turn armature current into torque? #

Torque in a brushed DC servo is armature current times the torque constant on the motor's datasheet: T equals Kt times Ia. With constant field flux that is a linear law, which is why the sizing arithmetic is so direct and why so many older machines ran brushed axes.

Worked example, with illustrative inputs and no measured motor behind them: take a brushed DC servo whose datasheet gives a torque constant of 0.40 N·m/A and a continuous current of 6 A. Torque is T = 0.40 N·m/A × 6 A = 2.4 N·m. In SI units the back-EMF constant carries the same number, 0.40 V·s/rad. At 3000 rpm the shaft speed is 3000 × 2π / 60 = 314.2 rad/s, so back EMF is 0.40 V·s/rad × 314.2 rad/s = 125.7 V. With an armature resistance of 1.5 Ω, the resistive drop at 6 A is 6 A × 1.5 Ω = 9.0 V, so the amplifier must supply about 125.7 + 9.0 = 134.7 V — call it 135 V — to hold that torque at that speed. Those are example inputs: read Kt, Ke and Ra from the datasheet of the exact motor, because speed under load is set by the balance of applied voltage against back EMF plus resistive drop, not by voltage alone.

The same 2.4 N·m from a sinusoidal AC servo with the same 0.40 N·m/A figure also takes 6 A, but only if the drive holds that current in quadrature with the rotor field. A commutation error of 30 electrical degrees leaves about cos 30° ≈ 0.87 of the intended torque; at 90 degrees the current produces essentially no torque and appears to the drive as an error.

What does an AC servo drive have to know that a DC amplifier does not? #

An AC servo drive must know the rotor's electrical angle in real time and the motor's winding data, so feedback type, phase order, commutation convention and motor electrical data all have to match, or the axis stalls, jerks or overcurrents.

A brushed pairing only needs bus voltage, continuous and peak current, inductance range, feedback and regeneration handling. The brushless or AC pairing needs every one of those checks plus the commutation interface, and a drive and motor can have perfect voltage and current ratings and still be unusable together:

  • Phase order on U, V and W: a mismatch gives jerking, reversed torque or overcurrent. Confirm against the wiring data, then run the drive's phase-identification routine.
  • Rotor-position feedback: a mismatch in signal type, supply, polarity, resolution or alignment gives a wrong commutation sector. Verify signal type and pinout before power-up.
  • Commutation convention: a drive expecting trapezoidal hall sectors will not handle a sinusoidal feedback scheme correctly. Confirm which waveform the drive is set for.
  • Motor electrical data: wrong winding resistance, inductance and back-EMF constants give poor current-loop behavior and less torque than commanded. Enter the data for that motor rather than substituting a visually similar one.

The DC side has its own verification step: before committing an older brushed motor to an amplifier, measure the actual armature resistance, and the page on measuring a brushed DC shunt motor's armature resistance walks through that measurement. The four-point check in matching a servo drive to a motor before you buy covers the brushless side.

Before any phase-identification or commutation check, uncouple the motor from the load and be prepared for unexpected motion, because a wrong phase order can command full torque the instant power appears.

Can a brushless servo drive run a brushed DC motor? #

Often yes: many brushless amplifiers can feed a brushed DC motor through two legs of their three-phase bridge, using U and V and leaving W unused, because the DC motor brings its own commutation and ignores the hall inputs.

This works because a three-phase bridge is three half-bridges sharing one bus, and a brushed motor only needs one H-bridge worth of them. Where the drive offers a commutation-angle selector for 60 or 120 degree hall spacing, the 60 degree setting is typically the mode used for this, with the DC motor's two leads on two of the three phase outputs and the hall inputs left unconnected. The selector alone does not prove support, though: confirm from the drive's documentation that its operating mode, current sensing and protection behavior are valid with one bridge leg idle, and that its feedback requirement is satisfied. Never assume it from ratings alone.

The reverse claim — that a brushless motor's three phases could run three brushed motors independently — is false. The windings share one magnetic circuit, and the inverter legs share a DC bus, switching strategy, current measurement and protection, so the three outputs cannot act as three independent bidirectional channels.

How do brushes, inertia and torque ripple change the choice? #

Brushes wear out and add scheduled maintenance; brushless rotors carry their magnets on a lower-inertia assembly, so an AC servo of the same frame size accelerates faster, runs higher duty cycles and never needs a brush change — at the price of a stricter motor-and-drive match.

Brush and commutator condition affect contact resistance, current transfer, electrical noise and torque continuity, so a brushed axis needs periodic inspection and eventual brush replacement, especially at high operating hours. Brush dust is also conductive, which matters around unsealed encoders. On the AC side, rotor construction keeps inertia low — the reason is in why servo motor rotors keep inertia low — and sinusoidal commutation gives smoother torque at low speed than trapezoidal, which matters for positioning and visible surface finishes. Trapezoidal brushless sits between the two: no brush wear, but more torque ripple.

Which servo should you buy for your machine? #

Buy brushed DC when you need a simple, forgiving axis that any suitably rated amplifier can run and brush maintenance is acceptable; buy an AC or brushless servo when you need low inertia, high duty cycles, no brush upkeep or accurate positioning at speed, and select the drive with the motor as one system.

For each case, the decision is:

  • Retrofitting an older machine or building on a budget: a brushed DC servo plus a four-quadrant amplifier, sized by the Kt-times-current arithmetic above. If the machine's original motor is staying but the amplifier is not, check what decides old servo motor and new drive compatibility before ordering.
  • New axis with high duty cycle, fast reversals or no maintenance access: a matched AC servo kit — motor, drive and feedback specified together, with the commutation checks from the section above completed before purchase.
  • Middle ground needing no brushes but tolerance for some ripple: trapezoidal brushless, accepting the hall-angle convention and phase-order verification as part of the purchase.

The commutation difference is the whole decision: it sets what the amplifier must do, what feedback the axis needs and how much matching work stands between the motor you have and the drive you want.

Questions asked

Can a brushed DC servo motor run on a different brand of amplifier?

Usually yes, and far more often than a brushless motor can. The commutation is inside the motor, so there is no phase-order or commutation-convention problem. Check the amplifier bus voltage against the motor rated voltage, the continuous and peak current against the motor limits, the motor inductance against the amplifier allowed range, and the feedback interface.

Why do new machine tools almost always use AC servo motors?

No brushes to replace, lower rotor inertia for faster acceleration and reversals, and more continuous torque in the same frame size. The tradeoff is that the motor and drive must be a matched pair with compatible feedback, which makes surplus buying and mixing brands harder than it is with brushed DC.

Is a brushless DC servo motor the same thing as an AC servo motor?

Physically the two motors can be nearly identical. The practical difference is the drive waveform. Trapezoidal brushless commutation energizes two of the three phases at a time, stepping between sectors taken from hall sensors. Sinusoidal commutation continuously coordinates all three phase currents against rotor position, which gives smoother torque at low speed but needs finer feedback.

Does the PWM carrier frequency set the speed of an AC servo?

No. The carrier only switches the power devices fast enough to shape the winding currents. Motor speed follows the frequency of the fundamental rotating field that the modulation synthesizes, together with the motor pole count. Changing the carrier changes switching loss and audible noise, not the commanded speed.

What happens if the U, V and W wires are connected in the wrong order?

The drive commutates against a rotor position that does not match the phases, so the axis jerks, runs backwards, draws excessive current or refuses to start. Run the drive phase-identification routine with the motor uncoupled from the load, then verify direction with a small command before closing the position loop.

Keep reading

  • Explainer

    AC servo motor and VFD compatibility: what decides it

    A general-purpose V/Hz VFD cannot commutate a permanent-magnet AC servo: reported bench runs pushed 10–12 A into a 2 A motor with no usable torque, and a second servo grumbled and stalled. Buy a drive that documents the motor type, its feedback interface and a speed-control firmware variant, or a matched motor–amplifier pair, and commission uncoupled at the lowest command.

    Motors, gearboxes and drives sizing

  • Explainer

    DC servo motor power supply sizing from a nameplate

    Size a DC servo power supply from the nameplate's rated armature voltage and continuous current, never from the pulse amps or a software speed limit. A single-phase full-wave capacitor-input rectifier charges the bus to about RMS times 1.414, so a 1:1 120 VAC isolation transformer gives roughly 170 VDC, which PWM servo drives accept. Drives in parallel share one bus voltage; their continuous currents add.

    Motors, gearboxes and drives sizing

  • How-to

    How to Calculate Servo Motor Current From Required Torque

    Current follows commanded torque: divide required torque by the winding's torque constant, I = T/Kt. The continuous-current rating is a thermal limit, not a fixed draw. For the worked example of 3.02 N·m at 2160 rpm (683 W shaft), check the point on the 48 V torque-speed curve and size the supply from the drive's input-current spec.

    Motors, gearboxes and drives sizing