What Decides a Drive for a Resolver-Feedback AC Servo Motor

Motors, gearboxes and drives sizing Published 10 min read By AutomateDirectUSA engineering team

Short answer

A resolver-feedback AC servo motor needs a drive that reads resolver feedback or runs on a retrofitted encoder with hall commutation, accepts step and direction in position mode, and covers the motor's continuous and peak current at its voltage class. A lower supply class keeps the torque and caps top speed; work the checks in order and the decision follows.

On this page
  1. Which three checks decide the drive?
  2. Can a drive without a resolver input run this motor at all?
  3. Will the drive take step and direction from my controller?
  4. How much current does the drive need?
  5. How much top speed does the motor lose on a lower supply voltage?
  6. What symptoms tell me the match is wrong?
  7. In what order do I select and commission the drive?
  8. Which choice do I make for my case?
  9. Questions asked

A resolver-feedback AC brushless servo motor does not need one particular brand of drive; it needs a drive that passes three checks at the same time. The drive must read the feedback the motor actually carries, accept step and direction in position mode, and cover the motor's continuous and peak current at the supply's voltage class. Fail the feedback check and the drive faults at power-up, or the motor jerks and runs away on bad commutation. Fail the voltage check and the axis keeps its torque but surrenders top speed: on the worked example below, a 400 V-class motor on a 230 V supply gives up roughly 43 percent of its rated speed. Run the checks in order and the decision is mechanical.

Which three checks decide the drive? #

Three checks decide it: the drive must read resolver feedback (or the motor must move to encoder-plus-hall feedback), it must accept step and direction in position mode, and its continuous and peak current and voltage class must cover the motor's nameplate.

Record all three from the motor before you open a single drive catalog: the rated voltage class and rated speed, the continuous and peak current, and the feedback device with its resolver speed count. A motor that arrived without paperwork gets identified first — How to Identify Geared Resolver and Encoder Feedback on Old Servos shows how to tell what feedback device an old motor actually carries. This article gives the decision rules; Selecting a Replacement Servo Drive for Resolver Motors walks the drive-side search step by step.

Check What to compare Document that decides
Feedback The motor's feedback device against the drive's feedback input list Motor datasheet and drive feedback specification
Command The controller's pulse output against the drive's position-mode command sources Drive command interface manual section
Continuous current Drive continuous rating against motor nameplate continuous current Both datasheets
Peak current Drive peak rating against the acceleration duty Motor and drive datasheets
Voltage class Supply voltage against the motor's rated voltage class Nameplate and drive supply specification

Can a drive without a resolver input run this motor at all? #

Not by itself: a drive built for hall-and-encoder feedback has no resolver excitation output and no resolver-to-digital converter, so it cannot read the motor's feedback and will fault at power-up or refuse to enable.

A resolver is a rotary transformer. The drive feeds an alternating excitation, typically in the kilohertz range, to a stator winding; two windings on the rotor return sine and cosine signals whose ratio gives the shaft angle; and a resolver-to-digital converter inside the drive supplies that excitation and turns the signal pair into the digital angle the commutation logic uses. A hall-and-encoder drive has none of that hardware, so the mismatch is a capability gap, not a wiring fault.

Two routes close the gap. Route one is a drive whose feedback specification names resolver input: match the motor datasheet's resolver speed count and excitation requirements to the drive's resolver specification, and take the match from the specification page, not the brochure. Route two replaces the resolver with an encoder — physically straightforward, but commutation is the catch. The drive must know rotor angle relative to the stator phases, so the retrofit adds hall signals or uses a hall-less phasing routine, and the alignment to the motor's back-EMF must be verified before the axis is enabled. A misaligned retrofit produces the jerky, high-current, weak-torque behavior in the table below. The commutation rules for that swap are laid out in Swapping a Servo Resolver for an Encoder: Commutation Rules.

Will the drive take step and direction from my controller? #

Only if its command specification lists step and direction as a position-mode source: drives split into speed/torque-mode units that take an analog command, position/velocity-mode units that take pulses, and configurable units that do both once the command source is set, so read the command interface section of the manual before buying.

The speed/torque-only purchase is the classic mistake on the secondhand drive market, where listing titles rarely state the command interface. A step-and-direction input does not make the drive a stepper drive either: a stepper driver merely switches winding current in response to pulses, while a servo drive closes the position loop from the feedback device and computes commutation itself — which is why it needs motor data and tuning before it moves well, and why it holds torque across the speed range where a stepper falls off. When a Step and Direction Servo Drive Is Closed Loop separates the two cases.

Prefer differential step and direction inputs, two wires per signal, on twisted shielded pairs: they tolerate noise on the long runs a machine-built axis needs, while single-ended signals do not. If your controller outputs single-ended only, check the drive's input circuit and add a line driver where the manual requires one.

Set the drive's electronic gearing to the step resolution the controller expects, then check the pulse rate the gearing implies:

f_step (Hz) = (n_rpm / 60) × steps_per_rev

Illustrative example: an axis commanded to 3000 rpm with the drive set to 10000 steps per revolution needs 3000 / 60 × 10000 = 500000 Hz of step pulses. If the controller's maximum output frequency sits below that, raise the electronic gear ratio or cap the axis speed.

How much current does the drive need? #

Size continuous current at or above the motor's nameplate continuous rating and peak current at or above what the acceleration duty demands, because an undersized drive still runs the motor but caps its torque and acceleration.

Continuous current sets what the axis does forever — steady cutting, conveying, torque holding. Peak current sets acceleration. Compare both, in that order, and note that a smaller drive is not a broken drive: for an axis with gentle duty, a deliberately undersized drive is a legitimate choice as long as you chose it and sized the resulting torque limit.

Illustrative example with invented inputs, not a catalog rating: a nameplate lists 4.8 A continuous and 14.4 A peak. A drive rated 6 A continuous and 18 A peak covers both with margin. A drive rated 3 A continuous still turns the axis but holds torque near 62 percent of nameplate (3 / 4.8 = 0.625) and never reaches rated acceleration. Take the real comparison from your motor's nameplate and the datasheet of the exact drive model.

How much top speed does the motor lose on a lower supply voltage? #

The DC bus, not the motor, sets the ceiling: a drive fed at 230 VAC builds roughly 325 V DC, so a 400 V-class motor rated 4500 rpm tops out near 2600 rpm, with torque unchanged below that speed.

A brushless AC servo behaves like a brushed servo here: the voltage available to the motor scales with the drive's DC bus, so a drive that commutates the motor correctly at a lower bus still runs it, just with a lower speed ceiling. Below the ceiling, torque depends on the drive's current, not on the bus. Estimate the ceiling before you buy:

V_bus (V DC) ≈ 1.414 × V_line (V AC)

n_max (rpm) ≈ n_rated (rpm) × V_bus_available / V_bus_rated

Worked example, calculated for these inputs and not a measured result: one manufacturer's general-purpose resolver-feedback brushless servo family documents a 0 to 4500 rpm rated speed with 230 VAC and 400 VAC input classes — take your own values from the nameplate.

  • Available bus from a 230 VAC line: 1.414 × 230 V = 325 V DC
  • Rated bus for the 400 VAC class: 1.414 × 400 V = 566 V DC
  • n_max ≈ 4500 rpm × (325 / 566) = 4500 × 0.574 ≈ 2584 rpm, call it 2600 rpm — about 57 percent of rating

The same arithmetic on a 460 V-class motor fed from the same 230 VAC drive lands near a ratio of 0.50, so that ceiling sits at about half rated speed. This is a first-order estimate: it ignores the drive's voltage drops and any field-weakening range, so the speed-torque curve in the drive and motor datasheets stays the deciding document. If the machine truly needs rated speed, buy a drive built for the motor's supply class or feed the drive through a transformer — and if you raise a supply voltage, the rectifier and bus capacitors downstream must each be rated for the increase. One safety note belongs here: the drive's DC bus holds charge after power-off, so wait the documented discharge time and measure before touching the terminals.

What symptoms tell me the match is wrong? #

Match what you see at power-up to one of six failure modes, and run the first check in each row before replacing anything, because each symptom has more than one possible cause.

The feedback and command rows cover most failed matches between an older motor and a modern drive, so run those first.

What you see Likely cause First check
Feedback fault at power-up Drive expects encoder or hall signals; the motor carries a resolver Drive feedback input type against the motor datasheet
Enabled, no fault, pulses do nothing Drive is speed/torque mode only, or set to an analog command source The drive's command source or operating mode setting
Jerky motion, runaway, high current with weak torque Commutation not matched to the feedback device or the rotor angle The drive's phasing or commutation routine; retrofit alignment first
Runs correctly but tops out early DC bus below the motor's rated voltage class Nameplate voltage and speed against the supply, using the estimate above
Position lost or noisy on long cable runs Single-ended step and direction lines picking up noise Differential inputs on twisted, shielded pairs
Overcurrent trip under steady load Drive continuous current below the motor's Drive continuous and peak ratings against nameplate current

Do not assign a cause from the symptom alone; each row carries a confirming check. For the jerk-and-overload pattern specifically, Servo drive shows COM fault then overload: check U V W phasing first walks the phase-wiring check that rules out swapped U/V/W conductors before you blame the feedback.

In what order do I select and commission the drive? #

Record the motor nameplate and datasheet first, decide the feedback route second, and buy nothing until the command interface, the current ratings and the supply voltage have each passed their check in writing.

  1. Record the nameplate: rated voltage class, continuous and peak current, rated speed, feedback type. Pull the motor datasheet for the resolver speed count.
  2. Choose the feedback route: a drive with resolver input, or an encoder retrofit with hall commutation or a hall-less phasing routine.
  3. Shortlist only drives that list step and direction as a position-mode command source, with no hidden option required to unlock it.
  4. Compare continuous and peak current, and accept a smaller drive only if the axis duty allows the capped torque.
  5. Compute the bus-voltage speed estimate for your supply, then accept the ceiling or change the supply class.
  6. Wire the motor phases and protective earth, the shielded feedback cable, and the step, direction and enable lines — differential pairs for the pulses.
  7. Enter the motor data, then run the drive's phasing or commutation setup; with a retrofit, verify the alignment before enabling.
  8. Enable at low gain and a low current limit, tune the position loop, and set the electronic gearing so the required step rate stays inside the controller's maximum output frequency.

Expect to enter the motor parameters by hand: drive libraries rarely include a discontinued motor of this age, and the datasheet is the source for every value you type.

Which choice do I make for my case? #

Commit this way: resolver-input drive when the budget allows, encoder retrofit with hall or phasing commutation when it does not, position-mode step and direction drive for a pulse controller, and a supply class that delivers the top speed the axis actually needs.

  • Buying fresh: pick a drive whose feedback specification names resolver and matches the motor's resolver speed count, covers continuous and peak current, and runs from your supply class. No wiring changes inside the motor, one tuning session, done.
  • Working from drives on hand or the secondhand market, none with resolver input: retrofit an encoder with hall commutation or run a hall-less phasing setup, verify alignment to the back-EMF, and budget the extra tuning time.
  • Controller fixed on step and direction: filter to position-mode or configurable drives only. A speed/torque-only drive cannot take your pulses no matter how well the rest of the specification matches.
  • Supply below the motor's class: accept the computed ceiling if the axis never needs rated speed — torque survives intact — otherwise change the supply class or pick a drive for the higher bus instead of buying on current alone.

Questions asked

Why do servo motor builders fit a resolver instead of an encoder?

A resolver is a wound rotary transformer: the drive feeds an alternating excitation to a stator winding and reads sine and cosine signals from the rotor, so there are no optics or chips mounted on the shaft to break. That construction shrugs off dust, oil and shock, which is why harsh-environment motor families specify them.

What speed can I expect feeding a 400 V-class motor from a 115 V line?

Roughly 29 percent of rated speed. The bus from a 115 VAC line is about 163 V DC against about 566 V for the 400 VAC class, and 4500 rpm times that ratio lands near 1290 rpm. Treat it as a first-order figure; the drive's speed-torque curve decides.

Does a retrofit encoder need hall commutation or can the drive learn the angle?

Either, depending on the drive. Drives designed for hall-plus-encoder feedback want the hall channels wired to their commutation inputs. Drives with a hall-less commutation setup energize two phases, have you rotate the shaft or the encoder through a documented procedure, and store the resulting offset. Read the drive's commutation section before choosing the retrofit encoder.

Can one drive family cover both resolver motors and encoder motors?

Some drive families accept switchable feedback types, and their selection guides list which feedback each model reads. The test is the drive's feedback specification itself: if the input list names hall switches and incremental or absolute encoders but never a resolver, that model cannot run this motor without the retrofit route.

Keep reading

  • Selection guide

    What Decides a 110 VDC Servo Drive Replacement on Old Mills

    A replacement drive for a 110 VDC brushed servo must have a bus rating above the measured unloaded DC bus peak of the existing supply, continuous and peak current at or above the motor nameplate, and a feedback and command interface your controller already speaks. An 80 V drive caps speed near 73 percent of rated.

    Motors, gearboxes and drives sizing

  • Explainer

    AC servo motor and VFD compatibility: what decides it

    A general-purpose V/Hz VFD cannot commutate a permanent-magnet AC servo: reported bench runs pushed 10–12 A into a 2 A motor with no usable torque, and a second servo grumbled and stalled. Buy a drive that documents the motor type, its feedback interface and a speed-control firmware variant, or a matched motor–amplifier pair, and commission uncoupled at the lowest command.

    Motors, gearboxes and drives sizing

  • How-to

    Running a 90 VDC Gear Motor on a Step-and-Direction Drive

    Yes, a 90 VDC gear motor with a quadrature encoder runs well on a step-and-direction servo drive, but only if the DC bus stays below the drive's maximum input. Set the supply to about 75 VDC on a drive rated 80 V maximum, wire one drive per axis with its own encoder feedback, and delete the 24 V direction relays: the drive reverses the motor internally.

    Motors, gearboxes and drives sizing