What Ex h IIB T4 Gb means on an ATEX pneumatic actuator

Pneumatics and hydraulics Published 8 min read By AutomateDirectUSA engineering team

Short answer

II 2G Ex h IIB T4 Gb is the ATEX marking for a non-electrical actuator built for surface-industry gas atmospheres: category 2G equipment for Zone 1 and 2, gas group up to IIB (ethylene, not hydrogen), maximum surface temperature 135 °C (T4), EPL Gb. The h covers the ignition sources of the mechanical device itself; solenoid valves and positioners carry their own marking.

On this page
  1. What does the h in Ex h IIB T4 Gb mean on a pneumatic actuator?
  2. How do you read II 2G Ex h IIB T4 Gb field by field?
  3. Which ignition sources does Ex h cover on an air cylinder?
  4. Is Ex h the same thing as constructional safety c, ignition-source control b, or immersion k?
  5. Example: does II 2G Ex h IIB T4 Gb cover an actuator on a Zone 1 ethylene line?
  6. Which documents prove what the nameplate claims?
  7. How do you verify the installed actuator against the area classification?
  8. Questions asked

II 2G Ex h IIB T4 Gb on a pneumatic actuator is the ATEX marking for non-electrical equipment: a surface-industry device rated for Zone 1 gas atmospheres, assessed for gases up to group IIB, with its hottest surface capped by the T4 temperature class and a high protection level, Gb. The h is the part that catches people out — it is not an electrical protection concept but the family marking for purely mechanical equipment, and it has been in the directive's marking practice since around 2016. The nameplate is the claim; the Declaration of Conformity and the instructions are the proof, and they name the protection methods the marking leaves off. The sections below decode each field, work a fitting example, and end with the checks to run before the actuator enters the classified area.

What does the h in Ex h IIB T4 Gb mean on a pneumatic actuator? #

The h is the ATEX letter for non-electrical equipment: it says the actuator's mechanical ignition sources — seal and bearing friction, impact sparks, hot surfaces, electrostatic charge — were assessed to EN ISO 80079-36, with no electrical arc or spark in scope at all.

A pneumatic actuator has no circuit to spark, so the standard behind the letter is about the machine itself. EN ISO 80079-36 sets the general requirements for non-electrical explosion-protected equipment, and the h entered marking practice with its 2016 edition; EN ISO 80079-37 holds the protection methods that sit under it. That is why h looks new on older nameplates: equipment placed on the market before then ran on earlier paperwork, and manufacturers had a transition window to bring their declarations up to date. The same marking shape appears under IECEx for non-electrical equipment, so an Ex h reading decodes the same way outside Europe.

How do you read II 2G Ex h IIB T4 Gb field by field? #

Read it left to right as six independent checks — surface-industry gas atmosphere, built for Zone 1, non-electrical protection, gases up to group IIB, hottest surface 135 °C, and a high protection level — and the actuator fits the site only when every single check passes.

Field What it says What it admits
II Equipment group: surface industries, gas atmospheres Not group I mining gear
2G Category 2 for gas Zone 1, and it may also serve Zone 2; never Zone 0
Ex h Non-electrical protection family, EN ISO 80079-36 The applied methods are named in the documents
IIB Gas subgroup IIB Covers IIA and IIB gases; excludes IIC — hydrogen, acetylene
T4 Temperature class: hottest surface capped at 135 °C The gas's auto-ignition temperature must sit above it
Gb Equipment protection level: high for gas The EPL form of category 2G

Each field is a separate gate: a perfect temperature match cannot rescue a failed gas group, and the right category cannot stretch to Zone 0. The ladder also answers the opposite question — where the area is classified Zone 2 only, II 3G is the matching rating, the same logic that leaves Zone 2 relief valves marked II 3G rather than II 2G or IIB.

Which ignition sources does Ex h cover on an air cylinder? #

The h assessment covers the mechanical device alone — friction heat from seals and bearings, sparks from metal-to-metal contact, hot surfaces, static charge on plastics — while everything electrical bolted to the actuator carries its own marking.

The moving metal in a cylinder carries the friction heat that sets the temperature class, and end-of-stroke impact is an ignition source the design has to contain. The instruction limits — medium temperature, ambient temperature, cycling rate, lubricant type — are part of that assessed basis, which is why the temperature class is only valid inside them. The moment a pilot solenoid, a limit-switch box or a positioner is bolted on, you have added electrical equipment with its own marking and its own certificate, and the actuator's h says nothing about it. The naming split between pneumatic vs electro-pneumatic valve names is its own subject, but the marking split is absolute: one device, one marking, one assessment.

Is Ex h the same thing as constructional safety c, ignition-source control b, or immersion k? #

No — h is the family marking for non-electrical equipment, while c (constructional safety), b (control of ignition sources) and k (liquid immersion) are the individual protection methods a manufacturer may apply to reach it; the applied methods appear in the documents, not on the nameplate.

EN ISO 80079-37 defines the three methods: c, constructional safety, designs the ignition source out with dimensions, materials and clearances; b, control of ignition sources, adds means that detect or suppress them; k, liquid immersion, keeps the explosive atmosphere away from ignition-capable parts. A dry-running pneumatic actuator most often leans on constructional safety — clearances and material pairs chosen so ignition-capable events cannot develop — but do not infer it from the marking. The documents state the method, and if they stay silent, a written query to the manufacturer with the nameplate marking and serial number settles it. The route from ignition-hazard list to marking letter is the manufacturer's certification exercise: selecting ATEX certification for non-electrical equipment walks that route field by field.

Example: does II 2G Ex h IIB T4 Gb cover an actuator on a Zone 1 ethylene line? #

Yes for these inputs: the zone, gas-group and temperature checks all pass — the category covers Zone 1, group IIB covers ethylene, and ethylene's auto-ignition temperature of about 425 °C sits 290 °C above the 135 °C T4 surface ceiling.

The three checks run in order:

  • Zone. The line is classified Zone 1, and the category 2 rating with EPL Gb is built for Zone 1 and may also serve Zone 2. Pass.
  • Gas group. Ethylene classifies as group IIB, and an IIB marking covers IIA and IIB gases. Pass.
  • Temperature. Ethylene's auto-ignition temperature is about 425 °C and the T4 ceiling is 135 °C, so the margin is 425 °C - 135 °C = 290 °C. Pass.
  • Instruction limits. These are illustrative figures for the shape of the check: say the instructions state the assessment holds to a 60 °C ambient and the area reaches 45 °C — 45 °C sits below 60 °C, pass. Read the real ambient and medium limits from your actuator's instructions; the temperature class was derived inside them.
  • Counter-case. Put a hydrogen line in place of the ethylene: hydrogen's auto-ignition temperature is about 560 °C, so the temperature check would pass with room to spare, but hydrogen is group IIC, outside the IIB marking — and one failed field decides the whole marking.

Decision: for Zone 1, ethylene and an ambient inside the instruction limits, the nameplate marking covers the actuator; swap hydrogen in and the same checks refuse it.

Which documents prove what the nameplate claims? #

Three documents carry the proof — the Declaration of Conformity citing Directive 2014/34/EU and the EN ISO 80079 pair, the manufacturer's instructions holding the operating limits behind the temperature class, and the technical file the directive lets the manufacturer keep for itself.

Directive 2014/34/EU lets a category 2 non-electrical device reach conformity through the manufacturer's own internal production control, so there may be no third-party certificate number to chase at all — the Declaration of Conformity and the instructions are the whole public trail. Work the trail in this order:

  • Nameplate alone: a claim — group, category, gas group, temperature class — with nothing behind it.
  • Baseline: nameplate plus Declaration of Conformity citing Directive 2014/34/EU and the EN ISO 80079 pair, plus instructions stating the limits: medium and ambient temperature, cycling rate, permitted lubricants, static-charge precautions. A declaration issued before the transition to the h letter closed should be refreshed before you rely on it.
  • Escalate to a written query to the manufacturer, quoting the nameplate marking and serial number, when the documents do not name the applied method, when the process runs near the T4 ceiling, or when the actuator works in a non-standard configuration.

How do you verify the installed actuator against the area classification? #

Compare four things at the machine: the zone drawing against the category, the gas group against IIB, the gas auto-ignition temperature against the T4 ceiling, and the measured ambient and medium temperatures against the limits in the instructions — plus every accessory's own marking.

  • Pull the area classification drawing and read it against the marking: zone against category, gas group against IIB, gas auto-ignition temperature against the T4 ceiling.
  • Record the conditions the documents assume: ambient at the actuator, medium temperature, cycling rate — a breach of those limits voids the temperature class even when the letter looks right.
  • List every accessory — pilot solenoid, limit-switch box, positioner — and match each one to its own marking for the same zone, gas group and temperature class.
  • Inspect the fitted unit: no coatings or plastics outside the instruction's static-charge allowance, no debris packed into the moving parts, lubrication as specified.
  • File the nameplate photo, the Declaration of Conformity and the instructions in the equipment dossier for that tag.

The logic scales to any air-driven equipment entering a classified area: choosing an air-driven hoist for a 650 kg Ex-zone lift applies zone, gas group and temperature to a lift the same way.

One safety note: decoding a nameplate is not a safety validation — the zone classification and the final installation check belong to the site's hazardous-area assessment under the IEC 60079 series.

Questions asked

What category and protection level does a Zone 0 installation need?

Zone 0 needs category 1G equipment, protection level Ga. A category 2 actuator with Gb is a Zone 1 device: it may also serve Zone 2, but it must not sit in Zone 0. For dust atmospheres the parallel categories are 1D, 2D and 3D with protection levels Da, Db and Dc.

Which temperature class does a gas with a 200 °C auto-ignition temperature need?

The maximum surface temperature of the equipment must stay below the gas's auto-ignition temperature. The class ladder runs T1 at 450 °C, T2 at 300 °C, T3 at 200 °C, T4 at 135 °C, T5 at 100 °C and T6 at 85 °C, so a 200 °C gas rules out T3, which sits at its own ceiling, and selects T4 or lower.

Can an actuator marked IIB run on hydrogen or acetylene?

No. Both gases belong to group IIC, and a marking up to IIB covers only IIA and IIB; lowering the pressure or the concentration does not change the gas group. Fit equipment marked IIC for those gases, or obtain a written extension of the assessment from the actuator's manufacturer.

Does the Ex h rating survive a repair with third-party seal kits?

The assessment assumes the manufacturer's specified seals, lubricants and clearances: they set the friction heat behind the temperature class and the material pairings behind the spark and static checks. Fit unspecified parts and the marking no longer describes the device, so use original or manufacturer-approved parts and record the repair in the equipment dossier.

A Declaration of Conformity cites the old ATEX directive — is it still valid?

A declaration referencing directive 94/9/EC predates the Ex h letter and should be replaced: manufacturers had until October 2019 to issue declarations reflecting EN ISO 80079-36 under directive 2014/34/EU. Ask the manufacturer for an updated declaration, quoting the full nameplate marking and the serial number.

Keep reading

  • Selection guide

    Choosing an Air-Driven Hoist for a 650 kg Ex-Zone Lift

    Lift the 650 kg with a purpose-rated pneumatic chain hoist whose nameplate category matches the Ex zone. The payload hangs at about 6.38 kN, and a hydraulic cylinder fed compressed air cannot hold it: its seals are chosen for oil and it is not a rated lifting machine.

    Pneumatics and hydraulics

  • Explainer

    Actual volume vs free air displacement in pneumatic actuators

    Actual volume is the physical chamber volume the piston sweeps at working pressure. Free air displacement is that same air restated at atmospheric pressure: multiply the chamber volume by the ratio of absolute working pressure to absolute atmospheric pressure, then by cycle rate for CFM.

    Pneumatics and hydraulics

  • Comparison

    Electric vs pneumatic butterfly valve actuator comparison

    Choose a modulating electric actuator when the valve must hold set positions between open and closed under a digital command and you would rather not run compressed air to it; choose pneumatic when the 90° stroke must finish in one to three seconds, when the process needs a spring-driven fail-safe action, or when the valve sits somewhere an electric drive would need certified explosion-proof construction. Size either type to exceed the valve's break torque by at least 25% at minimum supply pressure, on an ISO 5211 mounting interface.

    Pneumatics and hydraulics