AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

What separates a servo drive from a variable frequency drive

Servo and stepper motion Published 9 min read By AutomateDirectUSA engineering team

Short answer

A servo drive closes current, speed and position loops against encoder or resolver feedback; a VFD regulates voltage and frequency alone and never measures shaft position. Name the feedback, the operating modes and the duty, and you have chosen the drive family.

On this page
  1. What actually separates a servo drive from a VFD?
  2. Which control loops does each drive close?
  3. What does the CiA 402 drive profile require?
  4. Can a VFD position an axis on its own?
  5. How much stopping-position drift does open-loop control leave?
  6. How do you tell which drive family a machine's axis uses?
  7. Which drive does your axis need?
  8. What changes at commissioning between the two?
  9. Questions asked

The separation is feedback. A servo drive closes a position, speed or torque loop against a measurement taken at the motor shaft; a variable frequency drive (VFD) regulates only the voltage and frequency it feeds the motor and never measures where the shaft sits. Everything that follows — the nested loops, the CiA 402 operating modes, controlled torque at zero speed, the motor identification step at commissioning — comes from that one difference. This page gives the dividing line in standards terms, a worked stopping-accuracy example with the arithmetic shown, and the identification checks that sort an unknown axis into servo, stepper or inverter territory before you buy a single part.

What actually separates a servo drive from a VFD? #

A servo drive closes a position, speed or torque loop against measured rotor feedback, while a variable frequency drive regulates only the voltage and frequency it applies to the motor and measures no shaft position at all.

Both families live under the same umbrella standard: IEC 61800 covers adjustable-speed electrical power drive systems, with Part 5-1 for electrical safety requirements, Part 3 for EMC and Part 5-2 for drive safety functions such as safe torque off. The standard classifies drives by function, and the function that splits these two is what the drive measures and which loop it closes.

Property Servo drive Open-loop VFD
Measured at the shaft Encoder or resolver feeds every loop Nothing measured; frequency commanded, slip assumed
Loops closed Current, speed and position Current limit and a speed model at best
Torque at zero speed Controlled and sustained Not controlled without rotor position
Command interface Motion operating modes (profile or cyclic synchronous) Speed or frequency reference
Motor Permanent-magnet servo motor, identified to the drive Induction motor, nameplate data entered
Sizing basis Continuous and peak torque against duty Load torque and motor current

The consequence is felt, not just read. A servo axis holds a load motionless at standstill with controlled torque and corrects every count of its feedback device; an open-loop VFD commands a frequency and assumes the slip, so where the shaft stops — and whether it stays stopped against a live load — is nobody's measurement.

Which control loops does each drive close? #

A servo drive runs three nested loops — current inside speed inside position — every one of them correcting against a measured feedback signal, while a VFD on basic V/f control closes only a current-limit loop and a speed estimate with no measurement at the shaft.

The current loop is the fastest and is what turns a torque command into real motor torque; the speed loop wraps it and the position loop wraps the speed loop. Where the position loop closes — in the drive or in the motion controller — decides which device owns the feedback and which device generates the reference, and the page on servo control loops in the drive or the controller works that choice through.

On the inverter side, V/f control keeps voltage roughly proportional to frequency so motor flux stays roughly constant; the motor's slip then follows the load, unmeasured. Sensorless vector control estimates speed from the electrical model — better low-speed behavior, still no shaft measurement. A servo loop sees commanded minus measured every control cycle, a number it can drive toward zero; an open-loop VFD has no equivalent number, which is why its error only surfaces at the process.

What does the CiA 402 drive profile require? #

IEC 61800-7 carries the CiA 402 drive profile, which defines the operating modes a motion drive offers — profile position, profile velocity, profile torque, homing and the cyclic synchronous modes — so a controller can command motion in a standard way.

In plain terms, CiA 402 defines a drive state machine and a set of operating modes: profile position, profile velocity and profile torque, where the drive closes the loop against its own feedback; cyclic synchronous position, velocity and torque, where the motion controller closes the loop once per bus cycle; plus homing. A drive listing those modes is built to be commanded as a motion axis.

The profile also keeps the boundary honest: a VFD on the same network can speak CiA 402 for velocity mode, because the profile is a command language, not a promise. The servo function is a position operating mode backed by a position loop and feedback. Read the mode list in the exact drive manual — that list, not the word servo on the label, is the specification.

Can a VFD position an axis on its own? #

No — an open-loop VFD regulates speed but never shaft angle, so it cannot stop an axis at a mark or hold it against load at standstill; positioning needs a position loop, and that is servo territory.

Three cases cover the field. An open-loop V/f drive has no position signal anywhere: stopping is a ramp and the stopping point floats with load torque. A closed-loop vector VFD with an encoder input regulates speed tightly and can hold near zero speed, but most such drives still close no position loop — the encoder refines speed and torque, not angle. A few drives list a position or indexing mode; then the manual is describing a servo function on that hardware, and its stated accuracy and duty are the numbers to hold it to.

If you are converting an axis from inverter control to real motion, where the position loop closes decides the whole architecture — controller location, feedback wiring and commissioning order all change with it, and where the position loop closes decides your servo conversion takes that decision apart.

How much stopping-position drift does open-loop control leave? #

On the cut-to-length axis below, a 40 percent swing in load torque shifts an open-loop stopping point by about 2.4 mm of web — more than double the ±1 mm tolerance — while the servo axis holds the same stop to within a tolerance worth 318 encoder counts.

Worked example, with the inputs stated: roll diameter 100 mm (circumference π × 100 mm = 314.2 mm), gearbox 10:1, line speed 0.6 m/s, cut tolerance ±1 mm, stop ramp 0.25 s, induction motor nameplate 1455 rpm at 50 Hz, load swinging between 60% and 100% of rated torque, and on the servo side a feedback device of 10000 counts/rev. This is a calculated example for those inputs, not a measured result.

Open-loop side, arithmetic in order. Synchronous speed for a 4-pole motor at 50 Hz is 1500 rpm, so nameplate slip is 1500 - 1455 rpm = 45 rpm at rated load. Slip scales nearly linearly with torque in the stable working range, so the 40% load swing shifts slip by 0.40 × 45 rpm = 18 rpm, and V/f control corrects none of it, because it commands frequency rather than shaft speed. Over the final 0.25 s of the move, 18 rpm = 0.30 rev/s travels 0.30 rev/s × 0.25 s = 0.075 rev at the motor, which is 0.0075 rev at the roll through the 10:1 gearbox, and 0.0075 rev × 314.2 mm ≈ 2.4 mm of web. The drift alone can double the tolerance before any mechanical error adds to it: open-loop control fails this axis.

Servo side. Roll speed is 0.6 m/s ÷ 0.3142 m = 1.91 rev/s = 114.6 rpm, so the motor turns 1146 rpm. One motor revolution moves the web 314.2 mm ÷ 10 = 31.42 mm, so 10000 counts/rev resolves 31.42 mm ÷ 10000 = 0.0031 mm per count. The ±1 mm tolerance is 318 counts; the position loop corrects every count, and at zero speed the drive still commands controlled torque. Resolution, loop and zero-speed torque — not motor size — are what buy this tolerance.

How do you tell which drive family a machine's axis uses? #

Read three things — the motor type on the nameplate, the feedback connector on the motor shell, and the drive's list of operating modes: a permanent-magnet motor with an encoder port and motion modes is a servo axis; an induction motor on a speed reference is not.

Run the checks cheapest first, because each one settles most machines on its own. Nameplate: a permanent-magnet servo motor lists torque and usually a feedback option code; an induction motor lists rated power, volts, amps and a speed just below synchronous. Feedback connector: a servo motor carries a dedicated encoder or resolver port, and the drive must accept that exact interface — for the resolver case, what decides a drive for a resolver-feedback AC servo motor is the interface pairing, not the power rating. Command path: analog speed-reference terminals point to inverter control; a motion network with selectable operating modes points to a servo drive. Duty rating: servo datasheets split continuous and peak torque with a time limit on the peak, so size from continuous and treat peak as a short-term budget.

One rule from the wiring stage saves drives: a connector that fits proves nothing about its signals. Pin assignments, feedback supply voltages and commutation signals come from the documentation for the exact drive, motor and feedback option, and guessing them can move an enabled axis the wrong way or leave it dead.

Which drive does your axis need? #

Choose the servo drive when the axis must stop at a position, hold torque at zero speed, reverse under load or track a motion profile; a VFD is the right drive when the job starts, runs at a set speed and stops without a required stopping position.

Indexing, registration, cut-to-length, electronic cam or gearing: servo drive. Continuous running at a commanded speed with no stopping position — fans, pumps, a main conveyor that never stops on a mark: VFD. Frequent reversing under load: servo. A vertical or live load held at standstill: servo, with the load supported before any brake releases.

If a stepper is the third candidate, decide it on torque and duty rather than habit, as stepper vs servo motor selection by torque and duty sets out. Sizing then diverges by family: a VFD is matched from the load's torque and the motor's current, which sizing a VFD from load torque and motor current works through, while the servo side computes current from required torque and checks it against the motor's continuous envelope, as how to calculate servo motor current from required torque shows.

What changes at commissioning between the two? #

Commissioning a servo drive means loading motor identification data and proving commutation and feedback direction before any real motion, while a VFD needs the induction motor's nameplate data entered for its speed model — the servo sequence is longer, and every step you skip is a torque-producing step.

The servo sequence runs: manuals for the exact drive, motor and feedback option first; power wiring, feedback shielding and protective bonding inspected with power isolated; motor identification and feedback configuration entered; commutation and feedback direction proven with restricted motion; loop tuning last. Motor identification is also what a replacement encoder has to re-establish, and commissioning a replacement servo encoder with motor ID data walks that job through. A motor-mounted holding brake follows the drive's sequence and is not a service brake for repeated stopping.

The VFD sequence is shorter: enter the induction motor's nameplate data for the speed model, choose V/f or sensorless vector control, set ramp times and current limits, run.

Safety note: commission with the machine secured against unexpected motion. A drive's stop command is an ordinary motion command; safety functions such as safe torque off come from IEC 61800-5-2, are wired and validated separately, and are chosen against the machine's risk assessment.

The decision in one line: stop at a position or hold torque at zero speed — servo drive, selected from the motor's identification and feedback; run between ramps with no stopping position — the VFD and the nameplate are the whole specification.

Questions asked

Can I run a servo motor on a variable frequency drive?

Not as a servo axis. A permanent-magnet servo motor needs rotor position to commutate, and an open-loop VFD applies voltage and frequency without measuring the shaft, so torque is uncontrolled at low speed and the motor can overheat or lose synchronism. Use the drive family the motor's documentation names, with the feedback interface that drive supports.

Do I size a servo drive like a VFD?

No. A VFD is matched to almost any induction motor within its current rating, so it is selected from load torque and motor current. A servo drive is matched to a specific motor family and feedback interface, so you select it from the motor identification, the continuous and peak torque envelope, and the duty cycle of the axis.

What does the holding brake on a servo motor actually do?

It holds the shaft against gravity or an applied load when the drive is disabled or powered down; it is not built to decelerate a spinning load repeatedly. Sequencing matters: the drive confirms standstill before applying or releasing the brake, and on a vertical axis the load must stay supported before brake release or torque removal.

Where does a stepper motor sit in this comparison?

Below both, on the feedback scale. A conventional stepper runs open-loop: the controller counts commanded steps, never measured position, so a stall is invisible. A closed-loop stepper adds an encoder and detects the stall. Neither provides a servo drive's controlled torque at zero speed against a live load, and that holding requirement is what pushes an axis to a servo drive.

Keep reading

  • Explainer

    Servo control loops in the drive or the controller

    Keep the current and speed loops in the servo drive, and close the position loop in the drive too. A position loop implemented in the controller runs no faster than the fastest task-class cycle, typically 1 to 10 ms, versus tens of microseconds in a modern drive — at 500 mm/s and 4 ms of delay that is already 2 mm of transport error. Default to drive-closed loops; move the loop into the controller only for slow, non-registration axes after measuring.

    Servo and stepper motion

  • Comparison

    A step and direction servo drive versus an open-loop stepper

    A step and direction servo drive takes the same pulse train as an open-loop stepper drive but closes the position loop inside the drive on the motor's encoder counts, so lost steps become a following-error fault instead of silent drift. The deciding arithmetic is the pulse budget: steps per inch times feed gives the steps per second your controller must supply, and a high-count encoder can exhaust that budget before the motor runs out of torque.

    Servo and stepper motion

  • Selection guide

    What Decides a Plasma Table Retrofit That Keeps the Original Servos

    Identify each servo drive's command and feedback interfaces before you buy anything: interfaces, not motor age, set the retrofit boundary. Keep the motors and drives when the new control chain can generate the command each drive accepts — commonly a ±10 V analog speed or torque signal — reproduce the enable, fault and limit lines, and close every position loop with valid feedback. If a drive's interface cannot be identified, replace that drive; keep the motor only when the replacement drive matches its ratings and feedback.