How-to
What sets the zero reference for axial displacement sensors
Short answer
Pick one zero reference before touching the sensor: the rotor at its running position, or the rotor at the midpoint of measured thrust-bearing float. For the mid-float method, measure total float five times with a dial indicator aligned on the shaft axis, average, halve the mean and seat the rotor at that midpoint without reversing direction. Hand push that repeats is enough; a controlled seating load applies only when the bearing documentation calls for one.

On this page
- What the zero reading does and does not prove
- Choose the reference: running position or mid-float
- Measure total float with a dial indicator
- Worked example: mid-float zero for 0.37 mm of total float
- Whether the push needs a controlled load
- Seat at midpoint, zero the channel, verify both directions
- The decision for each case
- Questions asked
A zero on an axial displacement channel proves the channel, not the rotor. Before you touch the sensor, pick one mechanical zero and stay with it for the whole job: the rotor held at its normal running position, or the rotor seated at the midpoint of measured thrust-bearing float. For the mid-float method, hand push is enough: move the rotor back and forth between the active and non-active pads five times with a dial indicator aligned on the shaft axis, average the five total-float readings, halve the mean, and seat the rotor at that midpoint without reversing direction. A controlled seating load applies only when the bearing documentation calls for one. The sections below give the choice, the measurement sequence, the arithmetic on a worked compressor example, and the verification that both pad seats land where the math says.
What the zero reading does and does not prove #
A zero indication proves only that the monitoring channel sits at its assigned reference. It does not prove the thrust collar is centered, and it does not tell you which convention the channel was calibrated to.
The channel exists because thrust position shifts as the bearing wears, and a large shift can bring the rotor into contact with the casing. That is why API Standard 670, which sets the minimum requirements for a machinery protection system, lists shaft axial position among the channels it covers and includes calibration of the axial position monitor. The standard governs how the measurement chain is built and checked; it does not choose your mechanical zero. That choice lives in the protection-system configuration, the configured alarm limits and the maintenance records for this machine.
| What you observe | What it points to |
|---|---|
| Display reads zero with the rotor at measured mid-float | the channel uses the midpoint convention |
| Display reads zero only at the established operating position | the channel uses the running-position convention |
| Float readings differ depending on travel direction | pad seating, indicator base, or applied push — mechanics first |
| Mechanical position repeats but the sensor reading does not | probe, target, mounting, cable, or channel |
| Display moves opposite to the indicated shaft movement | polarity or probe orientation convention |
If you cannot tell which convention the channel uses, stop adjusting the sensor calibration. Recalibrating electronics before the mechanical zero is established hides the real offset.
Choose the reference: running position or mid-float #
Running-position zero: the rotor sits at its normal operating equilibrium, held there by the operating thrust and the bearing oil film. A zero set this way reproduces the running thrust-collar position, so the display starts each run at zero.
Mid-float zero: geometric. You measure the travel between seated contact on each side of the bearing, halve it, and call the midpoint zero. In service the display reads the normal operating shift away from that midpoint, toward the loaded side — an expected reading, not a fault.
Commit to whichever convention the alarm limits already assume, because switching conventions changes how much indicated travel remains toward each pad. If the records are silent, for example after a controls retrofit, set mid-float and write the convention on the calibration sheet, so the next technician inherits the decision instead of rediscovering it.
Measure total float with a dial indicator #
Lock the machine out under the site isolation procedure before hands or tools go near the rotor, because a large train can turn from a shared driver, gravity, or stored process energy.
A tilting-pad thrust bearing carries its load on a wedge-shaped oil film between the rotating collar and pivoted pads, so a static push seats the pad stack through the assembled clearances — which is exactly why an inconsistent push gives inconsistent seating.
- Mount the dial indicator on a rigid support fixed to the machine structure, with the stem aligned on the shaft axis and the tip on a machined shaft surface. A loose magnetic base, an angled stem, side loading, or contact on a rough surface each corrupt the reading; the same alignment discipline as the center-hole indicator test for ball-screw endplay applies here.
- Push the rotor to one end of its travel until the thrust collar seats against the pad stack and the reading stabilizes, then record the dial reading without disturbing the base.
- Push the rotor to the opposite seated position and record again. The absolute difference between the two readings is one total-float result.
- Repeat the full back-and-forth traverse until you have five results.
- Average the five results and read the spread between the smallest and largest. A stable average with wide individual variation is not a reliable reference: fix the seating, the base, or the push before you zero anything.
Machine-tool ballscrews ask the same of their thrust bearing sets, where axial play and preload on a ballscrew thrust bearing are set by seating the bearing pair repeatably.
Worked example: mid-float zero for 0.37 mm of total float #
Inputs. Five dial readings across the full float, in millimeters: 0.36, 0.38, 0.37, 0.36, 0.38. The five-traverse method is the field practice above; the readings themselves are an illustrative example set — your machine supplies its own five numbers, and the result below is a calculated example for these inputs, not a measured result.
Rule. Mean total float equals the five readings added together and divided by five. Midpoint travel equals that mean divided by two.
Arithmetic. Sum: 0.36 + 0.38 + 0.37 + 0.36 + 0.38 = 1.85 mm. Mean: 1.85 mm divided by 5 equals 0.37 mm. Spread: 0.38 mm minus 0.36 mm equals 0.02 mm, about 5 percent of the mean. Half-float: 0.37 mm divided by 2 equals 0.185 mm.
Result. Zero sits 0.185 mm from either seated position, and once the channel is zeroed at midpoint, each seated position should read 0.185 mm from zero, one on each side under the channel's sign convention.
Decision. A spread near 5 percent of the mean is tight enough to zero. As a rule of thumb, treat a spread past roughly a tenth of the mean as a seating problem to fix before zeroing. Seat the rotor at the midpoint, set the channel zero there, and verify both seats against the half-float figure.
Whether the push needs a controlled load #
The rotor must seat both pad stacks repeatably, and tilting pads settle as load transfers through the assembly, so casual hand force can stop at slightly different points on each traverse. One reported field case, on a Kingsbury tilting-pad thrust bearing, pushed with roughly 50 to 150 psi. That figure is the loading pressure used in that one case, not a universal thrust force: pressure and force are different quantities, and the shaft force delivered by a loading piston equals the applied pressure multiplied by the piston's effective area, so the same pressure gives a different force on a different fixture. Do not carry those psi values into another hydraulic device without the bearing and compressor documentation; when a controlled seating load is specified, it comes from that documentation.
Decision: if no controlled load is specified, use the smallest push that brings each traverse to a stable, repeatable seat, run all traverses, and let the spread decide. More force is not better — excess force deflects the indicator support, the shaft train, or the loading fixture, and yields a float value that looks precise but is biased. What makes the reference trustworthy is that the seat repeats under the same approach, not that the push feels firm — the same argument for why an R8 tool holder needs a repeatable axial seating datum.
Seat at midpoint, zero the channel, verify both directions #
- Pick either seated endpoint as the dial reference and note which one it is, active or non-active, with labels matching the machine drawing and the channel direction convention.
- From that endpoint, move the rotor toward the opposite side by the half-float travel and stop without reversing. If you overshoot, return all the way to the endpoint and approach again; a small reverse correction lets pad settling and lost motion move the final position.
- With the rotor held at midpoint, set the channel to zero following the procedure for the installed sensor and monitor. With a noncontact probe, check two things separately: the shaft is at mechanical mid-float, and the probe gap sits inside its documented usable range. Record the raw output before you adjust anything.
- Traverse to the active-side seat and record the dial and display readings, then move through midpoint to the opposite seat and record both again.
- Return to midpoint from the same approach direction and confirm the display returns to zero, then run the traverse once more to confirm both endpoints and the midpoint repeat.
- Record the calibration facts: which endpoint, the sign convention, the float readings with their mean and half-float, and the raw outputs, so the next technician inherits the convention rather than guessing at it.
The decision for each case #
Mid-float zero, machine down for bearing work: traverses with a shaft-aligned dial indicator, mean and half-float from the arithmetic above, rotor seated at midpoint without reversing, channel zeroed there, both seats verified against the half-float, convention recorded.
Running-position zero, convention confirmed in the protection system: established at the machine's documented operating condition under the compressor's own procedure, with the alarm margins confirmed to match that zero.
Unknown convention: set mid-float, record it, and reconcile the alarm limits to that convention before the machine runs — the limits and the reference must describe the same zero.
Questions asked
Is hand push enough, or should it simulate the operating thrust?
You are seating pads, not simulating operation. A mid-float zero is geometric, so operating thrust does not need to be reproduced; the push only has to end at a stable seat on each side, and the spread across the traverses tells you whether it does. One reported Kingsbury field case used about 50 to 150 psi of loading pressure; treat that as specific to that fixture. A controlled load is for when the pads will not seat repeatably by hand or the documentation requires one.
Where do the active and non-active labels come from?
From the machine drawing and the monitoring system's direction convention, not from whichever end of the travel is handier. Active is the side the rotor thrusts against in normal operation; non-active is the opposite, backup side. Use the same names on the calibration sheet as the drawing uses, because the axial channel's sign convention is defined against those labels, and a swapped pair makes every recorded displacement read backward.
Why does the display move opposite to the shaft movement?
Probe and conditioning systems define a direction convention: increasing gap can drive the signal up or down depending on the system. If the display runs opposite to the dial-indicated shaft movement, compare the channel's direction setting with the probe orientation and the drawing's active and non-active labels before touching the calibration numbers. Fix the convention first; recalibrating a channel whose direction is defined backward just moves the error to both ends of the span.
My float readings keep drifting in one direction. Is the sensor bad?
Not yet proven. The dial indicator reads mechanical travel before the monitoring channel enters the decision path, so direction-dependent drift usually means the pad stack seats differently after each reversal, the indicator base creeps, or the applied push varies. Correct those and measure again. Investigate the probe, target, mounting, cable or channel only once the mechanical position repeats and the sensor reading still does not follow it.
Can I set a running-position zero while the machine is shut down?
No. That reference depends on the operating thrust and the bearing's response in service, so it is established at the machine's documented operating condition, following the compressor's own procedure. If the machine is down for bearing work and you must zero statically, set mid-float, record that convention on the calibration sheet, and have the running-position zero and its alarm margins re-established at startup under the machine procedure.