Explainer
When a Collaborative Robot Can Run Without a Fence
Short answer
A cobot can run fenceless only under one of the four collaborative methods in ISO 10218-2 — safety-rated monitored stop, hand guiding, speed and separation monitoring, or power and force limiting — with a risk assessment that covers the real tool, payload, speeds and trapping points. Collision detection alone never authorizes removing the fence.
On this page
- What the standards actually require
- The four methods and what each one demands
- The contact limits that decide power and force limiting
- Worked example: the separation distance you must hold
- Tool, payload and trapping: what cancels fenceless
- The verdicts, case by case
- When the answer is still a fence
- Questions asked
A cobot may run without a fence when the cell operates under one of the four collaborative methods that ISO 10218-2 defines — safety-rated monitored stop, hand guiding, speed and separation monitoring, or power and force limiting — and the risk assessment for that cell, run with the real tool, payload, speeds and layout, shows that method's limits are met. Collision detection by itself never authorizes fence removal: the word describes an intended interaction, not a rating. The 2025 revision of ISO 10218 folded the ISO/TS 15066 detail into the main standard and now speaks of collaborative applications rather than "cobots", but the decision logic below is unchanged.
What the standards actually require #
ISO 10218-1 governs the robot as the manufacturer delivers it; ISO 10218-2 governs the integrated cell, and the guarding decision sits on the 10218-2 side with the integrator. The 2025 editions replaced the 2011 pair and absorbed ISO/TS 15066, which is now withdrawn. Three requirements carry the weight:
- The functions that make fenceless operation possible — the stop function, the speed limit, the force limit — must be safety-rated control functions meeting PL d with Category 3 structure under ISO 13849-1, unless the risk assessment shows a lower performance level is adequate for that function.
- The cell needs a task-based risk assessment (ISO 12100) covering every operating state: automatic running, teaching, setup, fault recovery, cleaning and maintenance — the states where shared-space assumptions break down.
- Collaborative describes the application, not the hardware. The same arm is a fenceless pick-and-place cell with a blunt gripper at low speed, and a serious hazard with a blade or a hot part on the flange.
The four methods and what each one demands #
- Safety-rated monitored stop. A person enters the shared workspace; the robot executes a safety-rated stop and holds it, drives enabled, until the space is clear. Fenceless works when entry detection is safety-rated — a scanner or a mat — and the stopped cell holds no residual hazard: no gravity-loaded axis that can drift, no tool that keeps spinning after the arm stops.
- Hand guiding. The operator moves the arm through a safety-rated guiding device with an enabling control, and the robot moves only through that device. This method covers teaching and setup; it says nothing about automatic cycles, which need their own method.
- Speed and separation monitoring. The robot must never be inside the protective separation distance while a person is; it slows, then stops, as the distance closes. The distance is computed, not guessed — the arithmetic comes from ISO 13855, worked below.
- Power and force limiting. Contact is expected and permitted, provided contact forces stay under the body-region limits. This is the mode most people mean by "cobot", and it is the only one in which touching a person is part of the design intent.
The contact limits that decide power and force limiting #
ISO/TS 15066 Annex A, carried into the 2025 editions, tabulates two limits for each body region: a quasi-static limit for clamping contact, where the arm presses a person against something, and a higher transient limit for free impact. Two anchor values show the scale: 140 N quasi-static for hands and fingers, 65 N quasi-static for the face, with the strictest numbers on the head and neck and larger allowances for big muscle groups.
Read the exact pair of values for every region the arm can reach from the standard's table, not from a brochure summary. Pressure limits are tabulated the same way, and a sharp edge or a small tool face concentrates pressure long before the force number looks dangerous. Verification is done with a calibrated force or pressure measurement device at cycle speed and real payload — never by a person taking the hit.
Worked example: the separation distance you must hold #
ISO 13855 gives the minimum distance between a person and the robot envelope as:
S = K × T + C
- K = 1600 mm/s, the walking-speed approach constant
- T = the total time from detection to standstill: worst-case robot stopping time plus scanner and safety-logic response
- C = 850 mm, the intrusion allowance typical for a horizontal safety laser scanner detecting a whole person
Example inputs, a calculated example rather than a measured result: the robot's safety-function documentation gives a worst-case stop of 0.45 s at full speed with the real payload, and the scanner and safety controller add 0.10 s.
T = 0.45 s + 0.10 s = 0.55 s S = 1600 mm/s × 0.55 s + 850 mm = 880 mm + 850 mm = 1730 mm
Full-speed automatic cycles therefore need the protective field roughly 1.75 m out from the envelope. If the cell sits closer to an aisle than that, the robot must already be in its slow state when a person approaches: with the reduced-speed stopping time of 0.18 s from the same documentation,
T = 0.18 s + 0.10 s = 0.28 s S = 1600 mm/s × 0.28 s + 850 mm = 448 mm + 850 mm = 1298 mm
That is the standard two-field arrangement: a warning field drops the robot to its assessed slow state, and a protective field set at the slow-state distance stops it. Stopping time dominates the result, and stopping time grows with speed and payload — which is why the payload entry in the controller must be true.
Tool, payload and trapping: what cancels fenceless #
- The arm's force limiting does nothing about process hazards. A spinning screwdriver bit, a grinding wheel, a hot weld joint and a laser are hazards of the tool, and no collision threshold on the arm limits them.
- Payload mass belongs in every contact calculation — the same inputs that selected the arm in the first place, as in sizing BLDC torque and reduction for a robot arm joint. A 5 kg part on the flange raises impact energy far past what the bare arm's limits were set for.
- Trapping points decide layouts. Wherever the arm can sweep a person against a fixture, a conveyor or the machine being tended, contact is quasi-static by definition and the lower limits apply. Clamping zones are the most common reason a "cobot" cell still ends up fenced.
The verdicts, case by case #
- Blunt gripper, light parts, contact forces measured under the Annex A limits, no clamping zones: run fenceless under power and force limiting.
- Sharp, hot or energized tooling: guard the tool or fence the cell; collision detection does not cover the tool's hazard.
- Heavy or fast-moving payload: use speed and separation monitoring with fields at the computed distance, or fence.
- Clamping zones in the layout: redesign the reach or fence; the quasi-static limits are the strictest numbers in the table.
- Hand-guided teaching only: the method covers setup; automatic cycles need their own method and their own assessment.
- A cobot tending a machine with its own hazard, such as a press: fence the machine hazard regardless of the arm's label.
The method above applied to your numbers is how the decision gets made; the document that stands behind it is the cell's risk assessment file, written for the tool and payload actually installed.
When the answer is still a fence #
A guard is not a demotion; it is the cheapest of the four methods when the hazard is fixed and the part handling is heavy. Interlock the doors per ISO 14119, and set the guard far enough back that the robot reaches a standstill before a hand can reach past the opening — the same ISO 13855 arithmetic with the guard-door response time in place of the scanner's. Most shops frame a guard like this from aluminum extrusion, joined with the aluminum extrusion accessories made for that profile system.
Questions asked
Is a cobot's collision detection a safety function?
Only when the manufacturer documents it as safety-rated and states the limits it enforces. Many robots also ship a non-safety collision detect meant to protect the arm; that is a convenience function and cannot justify removing a fence. Under power and force limiting, the function that enforces the contact limits must meet the performance level required by ISO 10218-1: PL d with Category 3 structure unless the risk assessment allows less.
How much force is a cobot allowed to contact a person with?
The quasi-static, or clamping, limit is 140 N for hands and fingers and 65 N for the face, from ISO/TS 15066 Annex A, now carried in the 2025 editions of ISO 10218. Transient, free-impact limits are higher, and every body region has its own pair of values. Take the numbers for the regions your arm can actually reach from the standard's table and verify them with a calibrated force gauge.
Does running the robot slowly make it collaborative?
No. A slow robot without safety-rated functions is only slow. Speed and separation monitoring counts as a collaborative method only when the monitoring is safety-rated and the distance is computed per ISO 13855; power and force limiting counts only when contact forces are limited to the tabulated values. Speed by itself is not one of the four methods.
Do the 2025 editions of ISO 10218 change an existing fenceless cell?
The 2025 revision replaced the 2011 editions and absorbed ISO/TS 15066, and it frames the subject as collaborative applications rather than cobots. Cells already built and validated keep the assessment they were commissioned under. Treat any modification — new tool, new payload, faster cycle, changed layout — as a new assessment against the current edition.
Can I test contact forces by touching the arm myself?
No. Verification is done with a calibrated force or pressure measurement device, at the speeds and payloads of the real cycle, against the body-region limits in the standard. A person taking the hit produces nothing repeatable and is not a recognized verification method.