AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Troubleshooting

Why a Servo Axis Runs Away at High Feed Rates

Servo and stepper motion Published 10 min read By AutomateDirectUSA engineering team

Short answer

A servo axis that runs fine at low feed rates and runs away only at high speed is either accelerating beyond its command, which points at the feedback or command path, or failing to follow the move, which points at torque, bus voltage or heat. Record commanded velocity, actual velocity, following error and motor current at the speed where the fault starts; the sign of the divergence decides the branch.

On this page
  1. Why does a servo axis run away only at high feed rates?
  2. Is it running away or failing to follow the commanded move?
  3. What should I record before touching the machine?
  4. Which encoder faults get worse as speed rises?
  5. Example: what do two traces decide for a Z axis faulting at 2,000 mm/min?
  6. Does a DC nameplate mean a brushed motor that needs a rebuild?
  7. What must be secured before testing a vertical Z axis?
  8. How do I prove which component is at fault?
  9. Questions asked

A servo axis that tracks cleanly at low feed rates and runs away only at high speed is reporting one of two different faults, and the drive's own monitors separate them. If the axis moves faster or farther than commanded, the fault sits in the feedback path or the command path, and it is usually repairable without rebuilding the motor. If the axis falls behind its command while drive current sits at its limit, the fault is torque, bus voltage or heat. Record commanded velocity, actual velocity, following error and motor current at the feed rate where the trouble starts: the sign of the divergence between commanded and actual decides which branch to work. This article walks that diagnosis in the order a technician meets it, ends with the decision for each trace, and covers the vertical-axis precautions that come before any teardown.

Why does a servo axis run away only at high feed rates? #

Because the two faults that depend on speed both scale with it: the feedback signal's event rate rises with speed until a marginal connection or sensor starts dropping counts, and the torque a motor can deliver falls with speed until the axis falls behind its command.

Both mechanisms are plain physics. A feedback device emits a fixed number of edges per revolution, so signal frequency rises in proportion to speed: a 2,500-line encoder on a motor spinning at 3,000 rpm delivers 3,000 ÷ 60 × 2,500 = 125,000 edges per second per channel, and a connector, solder joint or line receiver that carries 10 kHz without complaint can drop counts at 125 kHz. Those are example inputs and arithmetic for them, not a rating of any particular encoder. On the torque side, available torque falls as the motor's back-EMF climbs toward the drive's DC bus voltage, so a move that accelerates fine at low speed can fall behind at the top of the range.

A third pattern gets mislabeled as runaway: a loop made unstable by excessive gain. That failure appears during tuning rather than at one feed rate in production, and it is covered separately in why a servo axis runs away during tuning. A speed-dependent runaway on an axis that has run in production for years is almost never the loop gains.

Is it running away or failing to follow the commanded move? #

The sign of the divergence decides: actual velocity above commanded velocity is uncommanded acceleration from the feedback or command path, while actual velocity below commanded with drive current at its limit is a torque, bus-voltage or thermal shortfall.

The two look similar from across the shop, but the controller's data separates them immediately. A feedback device that under-reports motion convinces the loop the axis is lagging, so the loop adds torque and the axis overshoots: uncommanded motion with no excess command. A noisy command path does the same — an analog command picking up noise, or a pulse train losing steps at high frequency, adds motion the program never asked for. Both are feedback-or-command faults, and both worsen with speed because both involve signal rates.

The other branch is a real shortfall. Acceleration torque, gravity on a vertical axis and friction all compete for a torque reserve that shrinks as speed rises and back-EMF eats the voltage headroom; current pegs at the drive's limit and actual velocity flattens below command. That signature — actual below commanded with current at limit — is the torque-starved case, covered in detail in why a servo axis never reaches its commanded speed. Swapping an encoder on that branch changes nothing.

What should I record before touching the machine? #

Capture commanded velocity, actual velocity, following error, motor current and the active fault code at the feed rate where the fault starts, plus travel direction and how long the axis ran cleanly before it misbehaved, using the drive's own monitor screens before any wire is moved.

Read these from the drive's monitor or diagnostics screens at the fault point:

  • Commanded velocity against actual velocity. The sign of the divergence is the branch decision.
  • Following error against its configured threshold. This tells you whether the stop was the drive protecting the axis or the motion outrunning the protection.
  • Motor current against the drive's continuous rating. Current pegged at the limit means a torque shortage; current near zero during a runaway means the drive is being told to move, or the feedback is lying about position.
  • Where in the move the fault begins. During acceleration points at torque demand; during constant travel points at the feedback signal rate; during deceleration points at drive or regenerative limits.
  • Time to fault and motor temperature. A fault within moments of reaching the critical speed is a signal or command fault; a fault only after minutes of running adds thermal and duty-cycle checks.

Heat scales with the square of current, which is why the same axis cruises all day at low feed and overheats at high feed: with a winding resistance of 0.8 Ω, 6 A of continuous current makes 6 × 6 × 0.8 = 28.8 W of copper loss, while 12 A held at the limit makes 12 × 12 × 0.8 = 115.2 W — four times the heat from twice the current. Those are illustrative numbers for that resistance; take winding resistance and current ratings from the motor's datasheet.

Which encoder faults get worse as speed rises? #

The usual suspects are a damaged feedback cable, a loose or corroded connector, a cracked joint at the encoder board, contamination on an incremental disk, a failing line receiver, and a slipping feedback coupling, each fine at low speed and losing counts at high speed.

Each fails the same way: the signal is marginal, and raising speed raises the edge rate until the marginal element starts losing counts. Work from cheapest to most expensive:

  1. Reseat and inspect both ends of the feedback cable. Look for bent pins, corrosion, contamination and a strain relief that lets the cable flex at the connector.
  2. Flex-and-watch test on the stationary cable. With the servos disabled, flex and tug the cable along its length while watching the raw position count on the drive display; a jumping count with no motion is a cable or connector fault.
  3. Known-distance check. Command a fixed move and measure the actual travel; a mismatch between commanded and travelled distance localizes the fault to the feedback chain, and an alarm about the encoder connection is wiring first — see servo encoder connection error alarm: check wiring first.
  4. Inspect the feedback device itself per its service documentation. Contamination on an incremental disk, resolver faults and absolute serial devices fail differently, so confirm which feedback type the machine uses before measuring anything.
  5. Check a coupled feedback device for slip. On axes where the feedback device rides on its own shaft, loose set screws let the coupling slip under load and the loop sees lost motion it must chase; if the set screws are tight and the coupling itself is worn or scored, replacing it with a flexible shaft coupling matched to both shafts is the fix.

Only after these come the feedback device and motor hardware. A replaceable feedback module or a damaged cable fixes the fault without touching the windings; a rebuild answers bearing, brake or winding damage found by inspection, not a speed-dependent fault the traces have tied to feedback.

Example: what do two traces decide for a Z axis faulting at 2,000 mm/min? #

Convert the commanded feed first: on a Z axis faulting at a commanded feed of 2,000 mm/min, that command is 33.3 mm/s, and any trace that diverges from it by more than a few percent at the fault point decides the branch before the cabinet is opened.

Both traces below are hypothetical, recorded at the feed rate where the fault starts:

Trace A — runaway. With the commanded velocity at 33.3 mm/s and measured actual at 41.7 mm/s (2,500 mm/min), the axis runs (41.7 − 33.3) ÷ 33.3 = +25% beyond command while drive current stays well inside its rating. The axis is moving faster than any instruction, so the fault is the feedback path or the command path. Decision: reseat, test and inspect the feedback chain per the list above before ordering parts; the motor does not need a rebuild.

Trace B — stall. With the same commanded velocity and actual velocity flattened at 26.7 mm/s (1,600 mm/min), the axis falls (26.7 − 33.3) ÷ 33.3 = −20% short of command while current sits at the drive's limit. The drive is being told to move and cannot. Decision: mechanical binding, counterbalance condition, acceleration demand or drive sizing — an encoder swap changes nothing on this trace.

Trace A also shows why the machine leaves production first: an axis 8.4 mm/s over command for the half second an operator needs to reach the e-stop travels about 4 mm beyond where the program put it — on a Z axis, that margin is the part, the fixture or the spindle.

Does a DC nameplate mean a brushed motor that needs a rebuild? #

No: many servo motors marked DC are brushless constructions that draw DC power and let the drive commutate them electronically, so the label describes the supply bus, and a suspected encoder fault alone is never a reason to rebuild the motor.

Brushless construction is common on machine-tool axes because it removes brushes entirely: the motor takes power from the drive's DC bus and the drive commutates it electronically from rotor-position feedback. Confirm the construction from the drive's documentation — the commutation method and the feedback interface it requires settle brushed versus brushless — and photograph the complete nameplate, the drive identification and every feedback connector label before ordering parts. Match motor and drive documentation through the manufacturer or its distributor rather than trusting the label alone.

The distinction sets the repair scope. A brushless axis leans on that rotor-position feedback for commutation as well as position, which is exactly why feedback faults on brushless axes produce violent uncommanded motion. If the feedback device is a separate replaceable unit, the repair is that unit plus the drive's documented commutation and direction setup — mechanical fit alone does not establish electrical compatibility. Bearings, a brake or windings found damaged by inspection are the rebuild's business. An encoder suspicion, by itself, orders neither.

What must be secured before testing a vertical Z axis? #

Gravity turns this fault into a falling-axis hazard, so confirm the brake holds and the counterbalance is intact by the machine's documented service procedure before any high-feed test, and take the axis out of production until controlled tests have found the cause.

A Z axis holds its load with motor holding torque, the brake and often a counterbalance, and a feedback fault that derails commutation or position can upset all three at speed. Lock and tag out power before opening any feedback connector, and prove the emergency stop actually interrupts the drives.

Set the test up so a fault cannot do damage: short travel, guards closed, the axis started well below the critical feed and raised in steps only as fast as the traces stay clean. If the machine uses a pneumatic counterbalance, check its pressure supply before blaming the motor — lost counterbalance pressure makes every upward move look torque-starved and every downward move look like runaway; pneumatic counterbalance for a vertical Z axis covers that circuit.

How do I prove which component is at fault? #

Move the suspicion across the boundary: if the fault follows the drive when drive and command connections are swapped with a like axis, the drive or its command path is at fault, and if it stays with the axis, the motor, feedback device or cabling is.

Run the swap only after the traces have isolated the branch, with like-for-like hardware and the machine's documented procedure. Prove the safety circuit first, confirm which axis is actually faulting, then repeat the fault at reduced speed with all cables reseated. Order the exchanges from cheap to dear: feedback cables between axes before feedback devices, feedback devices before motors. If the fault follows the cable or the device, replace that; if it follows the drive, work the drive and its command input; if it stays with the motor across both, the fault is inside the motor — bearings, windings, brake or built-in feedback — and only then is a rebuild or replacement motor on the table.

Close the job the way you opened it: back up the drive parameters and export the alarm history before the first change, make one change at a time so the result stays traceable, and after the repair verify tracking over a known move, confirm direction and, if feedback hardware was replaced, complete the drive's documented commutation setup before returning the axis to production.

Questions asked

Does a DC label on a servo motor mean it has brushes?

Not necessarily. Brushless DC servo motors also draw power from a DC supply; the drive commutates them electronically, so the label describes the supply bus rather than the commutation method. A quick shop-floor check is the power leads: two heavy leads indicate a brushed motor, three indicate a brushless motor, and the drive's documentation confirms the construction before any part is ordered.

Can I stop the runaway by lowering the servo loop gains?

No. Reduced gains will make the motion less violent but hide the cause, and the axis will still lose counts or stall at the same feed rate. Fix the hardware fault first, then retune with the drive's documented procedure so the gains are set against healthy feedback.

Is it safe to release the Z-axis brake to watch the fault happen?

No. The brake is one of the things holding the load against gravity, so releasing it without supporting the load turns any feedback fault into a falling axis. Watch commanded velocity, actual velocity and current from the drive monitors with the brake engaged, and release the brake only by the machine's documented service procedure with the load secured.

Why does the axis behave for hours when I jog it slowly?

Jog speeds sit well below the critical feed rate, so both speed-dependent mechanisms stay dormant: the feedback signal's edge rate stays within what a marginal connection can carry, and the torque demand never approaches the drive's limit. An axis that behaves for hours at jog speed has proven only that the fault needs speed to show itself.

Keep reading

  • Troubleshooting

    Why a Servo Axis Runs Away During Tuning

    A servo that completes its commanded move, then throws itself into reverse at full speed while the velocity command has no effect, has a feedback fault: reversed encoder direction, or open, crossed or noisy encoder wiring. Uncouple the motors, verify feedback polarity and continuity with the drive disabled, then retune from default gains. Raising gains cannot fix positive feedback.

    Servo and stepper motion

  • Troubleshooting

    Diagnosing a Servo Axis That Jogs in Steps With Fluctuating Current

    Stepping motion with a 1-2 A current swing and clean encoder feedback means torque demand is changing along the travel: check brake drag, coupling condition, gibs and screw alignment under load before substituting drives or motors. Record current and encoder error together, work the cheap checks in order, and let the uncoupled motor test separate mechanics from motor.

    Servo and stepper motion

  • Troubleshooting

    Diagnosing Servo Axis Position Drift in the Drivetrain

    The drift is lost motion between the motor encoder and the load: the position loop closes at the motor shaft, so the gearbox, coupling, pulleys and belt sit outside it. Split motor-reported position from an independently measured load position at one reference with witness marks on every hub. A one-direction offset that grows for hours while the motor reads on target is index loss — slip or jumped teeth — until the marks prove otherwise.

    Servo and stepper motion