Short answer
A vertical Z axis that drops with servo power off is back-driving its mechanical drive, not losing a control setting. Find and restore the mechanical holding path — in one retrofit the fault was an extremely loose motor-mount belt tensioner — before fitting a brake or counterbalance. A regeneration resistor is never holding hardware, and tuning fixes powered motion only.

On this page
- Why does a vertical Z axis drop when servo power is off?
- Which mechanical faults let a vertical head back-drive?
- How do I fix a loose motor-mount belt tensioner?
- Does a regeneration resistor hold the axis in place?
- When does a vertical Z axis really need a brake or counterbalance?
- Should I tighten the gib screws to stop the drop?
- How fast should I tune the retrofit servo after the drop is fixed?
- Questions asked
A Z axis that falls when servo power is off has a mechanical problem, not a control one: an unpowered servo makes no holding torque, so the screw, belt, coupling and mounts are all that stand between the head and gravity. In the retrofit behind this article, the entire holding path ran through one motor-mount belt, and its tensioner had gone extremely loose. Tightening it fixed the drop. Inspect the mechanical holding path first, and only fit a brake or counterbalance if the axis still cannot hold itself once the mechanics are sound.
Why does a vertical Z axis drop when servo power is off? #
The axis drops because an unpowered servo produces no holding torque, and a ball screw carrying a heavy head needs very little torque to back-drive — in the reported retrofit the entire holding path ran through one motor-mount belt, and its tensioner had gone extremely loose.
While the drive is energized, the position loop actively resists gravity and the axis holds. Remove power through a normal stop, a supply loss or an e-stop, and the motor becomes a free-spinning body; the head then drives the screw backwards whenever the torque needed to back-drive it is less than the head weight produces. The intermittent behavior — drops sometimes, falls under fingertip pressure other times — is the signature of a restraint that is loose rather than absent: a slack belt sometimes grips and sometimes slips a few teeth before letting go completely.
You can check how small the barrier is. Take a calculated example for a head and spindle of 40 kg, a 5 mm lead ball screw at 90 percent efficiency, and a 1.5:1 belt reduction from screw to motor. The head weight is 40 kg × 9.81 m/s² ≈ 392 N, and the torque that back-drives the screw is 392 N × 0.005 m ÷ (2π × 0.90) ≈ 0.35 N·m, or about 0.23 N·m reflected to the motor shaft. A timing belt with a slack tensioner transmits nothing reliably at that level, so the head falls. These are example inputs, not measurements from any named machine.
Which mechanical faults let a vertical head back-drive? #
In this case the defect was an extremely loose belt tensioner on the servo motor mount, and the same axis can also lose its holding path through a slipping coupling, skipped belt teeth, or a slide loose enough to offer no resistance.
Work the list from the cheapest check to the most involved, and confirm each before moving on:
- Motor-mount belt tension and tensioner fasteners. Look for a tensioner backed off, elongated mounting slots, or a belt that deflects far too easily. Confirming check: with the head supported and power off, push the head and watch whether the belt slips on the pulley while the screw stays still.
- Belt teeth skipping under load. A worn or glazed belt can jump teeth even at correct tensioner position. Confirming check: tooth-shaped wear marks in the pulley gaps and a pitch mismatch when you roll the belt by hand.
- Coupling between motor and screw. Loose set screws or a failed flexible element let the screw spin free of the motor. Confirming check: mark motor shaft and coupling, press the head, and see whether the marks separate.
- Gibs and slides. Excessive slide looseness removes the friction that some machines rely on as part of static resistance. Confirming check: dial-indicator test for slide play before adjusting anything.
- The screw itself. A steep-lead, low-friction ball screw back-drives by design; this is the baseline the other items sit on, not a fault to repair.
How do I fix a loose motor-mount belt tensioner? #
Isolate and lock out the machine, support the Z head so it cannot descend, then restore the tensioner to the belt manufacturer's specified tension and torque every mount fastener before any power-off test.
That first sentence is the safety note and the procedure at once — a head that has already shown it can fall is a stored-energy hazard, and nobody inspects under it unsupported. Then: re-tension the belt to the drive manufacturer's value for that belt section and center distance, and torque the tensioner and motor-mount fasteners to their specified figures rather than to feel. Resist the urge to compensate with extra tension; timing belt manufacturers warn that over-tensioned belts stretch excessively and can cause heavy internal damage to the machine. Re-run the supported-head, power-off hand test after tightening, and then test a normal stop, a power-off and an e-stop as three separate events before cutting metal. If the belt turns out worn or unable to hold tension at the correct setting, the repair is replacing it — match a timing belt to the existing pulleys' pitch and width rather than reusing a glazed one.
Does a regeneration resistor hold the axis in place? #
No. A regeneration resistor only dissipates energy that the drive pumps back during powered deceleration; once drive power is removed it has no function at all, so it cannot hold a vertical axis against gravity under any wiring.
The confusion is understandable, because the resistor sits on the drive and gets warm during hard stops, which makes it look like braking hardware. It is a dump load. On this machine none had been fitted, and none was needed: at the rapids involved, the drive's ability to absorb deceleration energy was not the limiting factor. Fitting one now would add nothing to power-off behavior. The part that holds an unpowered axis is mechanical, and the section below covers what to add if the mechanics alone are not enough.
When does a vertical Z axis really need a brake or counterbalance? #
Only if the mechanical drive is verified sound and the axis still falls: then fit a spring-applied, power-released holding brake, or a pneumatic or gas-strut counterbalance sized to the head weight, and let go of the idea that either is optional once gravity wins.
Two hardware routes exist, and they do different jobs. A spring-applied brake mounts on the motor or screw shaft and clamps when de-energized, so it must be rated to hold the axis's back-drive torque with margin — in the worked example above, several times that 0.35 N·m at the screw, taken from the brake datasheet for the exact frame size. A counterbalance instead removes the load: pneumatic cylinders, gas struts or a counterweight carry most of the head weight so the screw never sees it. For how the pneumatic version is arranged on a retrofit, see Pneumatic Counterbalance for a Vertical Z Axis. For exactly what a motor brake does and does not do, including why it is not a stop for a moving axis, see What a Servo Motor Holding Brake Does and Does Not Do. A related failure mode to keep in view: an overpowered or wrongly set counterbalance makes the motor fight it while running, which is a common cause of a vertical axis servo motor overheating after counterbalance loss or mismatch.
On this machine the answer was none of the above — the tensioner repair restored the holding path, and no brake was added.
Should I tighten the gib screws to stop the drop? #
Only as a measured slide adjustment, never as the holding fix. Gib drag is uncontrolled friction that changes with wear, and a machine that relies on it to resist gravity is one gib tweak away from dropping again.
Adding gib friction was suggested in this case but never confirmed as part of the repair, so treat it as what it is: a way to correct genuine slide looseness, checked with a dial indicator and recorded before and after. A small amount of slide friction does add to the static resistance, which is why a tight machine sometimes feels like it holds better. But it is not a designed restraint, it degrades the slide's motion quality if overdone, and it hides the real fault. If the gibs are loose enough that the axis rocks under hand pressure, correct that as its own mechanical defect — then re-test the drop, because the tensioner or coupling behind it is still the likely cause.
How fast should I tune the retrofit servo after the drop is fixed? #
Tune after the mechanics are right, and treat the reported 9,600 mm/min test rapid and the final 5,000 mm/min X/Y and 1,500 mm/min Z limits as one machine's result, not defaults; tuning can never hold an unpowered axis.
The order matters because tuning cannot distinguish a mechanical fault from a bad gain set — it will simply fight whatever the mechanics give it, and the symptom will come back at the worst moment. On this machine the drive defaults were well off, and acceptable tuning was only reached after the tensioner was corrected. Testing reached 9,600 mm/min before the operator settled on 5,000 mm/min on X and Y and 1,500 mm/min on Z; those are reported settings from that one machine, sized to its mechanics, not values to copy. Tune with controlled moves and watch following error, stopping distance and repeatability, and keep the power-off drop test separate from every powered move. If a rough axis resists every gain change, see Why Gain Changes Cannot Smooth a Rough Servo Axis — the cause is usually still mechanical.
The decision, case by case: if the axis holds after the mechanical path is restored, stop there — no brake, no strut, no resistor. If it still falls with verified-sound mechanics, add a brake or counterbalance sized from the actual head weight and back-drive torque. Either way, never let tuning stand in for holding hardware.
Questions asked
Will higher servo gains stop my Z axis from dropping after an e-stop?
No. Servo gains produce holding torque only while the drive is energized. The moment drive power is removed, torque is gone and the axis is held by nothing but the mechanical path. Raising gains can mask roughness while the machine runs, but it cannot act after power-off or an e-stop.
What happens if I over-tension the motor-mount timing belt?
An over-tensioned timing belt stretches excessively, loads the motor and screw bearings, and can cause heavy internal damage to the machine. Tension to the belt manufacturer's specification for that belt section and center distance, then recheck after the first running period, because a new belt seats in and loses tension slightly.
Do steppers avoid this problem because they hold torque when unpowered?
A stepper has detent torque and holding torque in its energized detent position, but both are small compared with the weight of a typical milling head, and neither is a designed holding device. A vertical stepper axis still needs a sound mechanical restraint, brake or counterbalance, exactly like a servo axis.
How do I prove the drop is fixed before trusting the machine?
Support the head, remove servo power, and apply hand pressure at several points along the Z travel with everyone clear of the descent path. Watch what moves: the screw should not turn and the belt should not slip. Then restore power and test a normal stop, a controlled power-off and an e-stop as three separate events.