Comparison
Why peak servo torque ratings mislead a CNC mill retrofit
Short answer
Size every axis on the continuous S1 torque rating, not the peak number: a motor badged 9.8 Nm peak delivers only about 3.5 Nm continuous to 3000 rpm. A drive is compatible only when its feedback format, commutation data and configuration match the motor — an analog command input proves nothing. With two drives failed and one motor physically limiting travel, new matched motor-drive sets on all three axes are the lowest-risk repair.

On this page
Size every axis of a retrofit mill on the continuous S1 torque rating, and treat the peak number as a sprint figure that sizes nothing. On a mill in exactly this position — Y and Z motors badged 9.8 Nm peak, published continuous rating about 3.5 Nm up to 3000 rpm — that gap is the difference between a headline and a motor that holds through a full pass. A drive is not compatible with a motor just because both accept an analog command: the drive must also match the motor's feedback format, commutation data and configuration. With two of three drives already dead and the remaining motor physically limiting X travel, the lowest-risk repair is new matched motor-drive sets on all three axes, commissioned one axis at a time.
Peak torque is a sprint number #
The torque figure a listing or a nameplate leads with is the maximum: what the motor produces briefly, at low speed or stalled, for as long as the drive's overload curve allows.
The number that sizes an axis is the continuous duty rating — class S1 in the IEC 60034-1 duty-cycle definitions — the torque the motor turns into heat indefinitely at rated cooling and ambient temperature without overheating. Continuous torque holds to the motor's rated speed; above it, the available continuous torque tapers toward the maximum speed. For the fitted SureServo SVL-210 motors, the continuous curve holds to rated speed and falls away toward the 4500 rpm maximum.
A headline number is not wrong, it is just not a sizing number. Sizing asks what the axis holds for the whole pass, at the speed the pass runs, and only the S1 curve answers that.
The motors on the bench, read as datasheets #
Read every candidate the same way: continuous figure first, maximum second. The table collects what is documented for each motor on this bench, and where no datasheet turned up the figure stays untested rather than assumed. Demand also differs axis to axis on a knee mill — the servo motor sizing for a knee mill retrofit walk-through treats Z separately from X and Y.
| Motor on the bench | Headline figure | Continuous figure | Verified? |
|---|---|---|---|
| SureServo SVL-210, Y and Z | 9.8 Nm peak, 4500 rpm maximum | about 3.5 Nm to 3000 rpm, tapering above | Continuous curve published for the motor family; the drives failed |
| Fanuc 8F/2000, X | 12 Nm at 2000 rpm, reported | none found, so untested | Nameplate only; the motor body caps X travel |
| DMM 11A-DST-A6HK1, spares | 12 Nm peak at 3000 rpm | 4.4 Nm at 1500 rpm on the A11A-DST-A6HK1 datasheet line | Resolve nameplate against datasheet before quoting either |
| Allen-Bradley N-series with 1398-ddm-009 drive, stored | 7 Nm at 5000 rpm, reported | duty basis not established | Untested after years unpowered |
| LS APMC-FCL10AYK-AD on an L7C drive | 9.5 Nm at 5000 rpm, reported | duty basis not established | Analog command demonstrated working; smallest frame of the set |
The spare DMM motor shows the pattern at its sharpest: its datasheet line gives 4.4 Nm continuous at 1500 rpm against a 12 Nm maximum, a 2.7-to-1 gap between badge and holding number.
A worked example on one axis #
Size a real cut on the fitted Y or Z motor. The ratings are the published ones for that motor: 9.8 Nm peak against about 3.5 Nm continuous. The demand is an illustrative input — take yours from the drive's torque monitor during your worst pass. Say a climb cut holds 3.0 Nm at the motor, at 2500 rpm, for the length of the pass.
Margin on the continuous rating: (3.5 - 3.0) Nm / 3.0 Nm = 0.17, a 17% margin, at a speed inside the band where the continuous rating holds. The same cut sized on the peak badge: (9.8 - 3.0) Nm / 3.0 Nm = 2.27, a paper margin of 227% that assumes nothing about duration. The ratio between the two ratings, roughly 2.8 to 1, is how far the headline overstates what the motor holds.
The decision the arithmetic forces: a cut that holds more than the continuous line, or that needs its torque above 3000 rpm, does not fit this motor, whatever the badge says. If your worst pass reads over the continuous line, the motor is undersized — choose the next frame on its S1 curve, not its peak.
An analog command input proves nothing #
A drive cannot torque a brushless motor until it knows the rotor's electrical angle, and it learns that from the motor's own feedback, which is why drives run a commutation step at setup. The command input is a separate path. LinuxCNC closing the position loop through the Mesa 5i25/7i77 encoder inputs says nothing about what each drive sees from its own motor.
That is why every proposed swap on this bench fails on paper today. Moving the working Ultra 100 from X to the Y SureServo changes the feedback interface, the encoder counts, the motor current and the tuning the drive was configured for; its configuration follows the Fanuc motor, not the new one. The Ultra3000i paired with a SureServo motor is unproven too: reported figures put the two feedback resolutions at 10,000 against 8,000 counts per revolution, and if the nameplates confirm that, the pairing fails before the first move. Matched sets exist because feedback format, resolution, commutation data and configuration all have to line up; the full checklist is in what decides old servo motor and new drive compatibility.
Decision: no drive moves onto a different motor until the motor's feedback specification and a configuration written for that specific motor are in hand. Sharing an analog input is not compatibility.
The repair paths, compared #
Every path below restores Y and Z and clears the big Fanuc motor off X; they differ in how much unverified pairing each one carries. The end-to-end sequence for choosing and sizing the hardware is in selecting a servo motor and drive for a CNC retrofit.
| Path | For | Against | Decision |
|---|---|---|---|
| New matched motor-drive sets on all three axes | Every pairing documented by one vendor; analog command kept if the chosen drives support it; X travel restored | Commissioning work on every axis | Take it — the lowest-risk repair on this bench |
| LS L7C set on X first | Analog operation demonstrated; smallest motor clears the Y ways | Y and Z still unsolved | The staged fallback if the budget lands before the parts do |
| Working X Ultra 100 moved to the Y SureServo | A drive known to run | Feedback interface, counts, wiring and tuning written for a different motor | Do not install without a documented compatibility audit |
| Ultra3000i on the Z SureServo | Drive tested working | Commutation and count match unverified | Bench candidate only, never a plug-in replacement |
| DMM DYN4 sets | Low-hour matched hardware | Erratic analog history; modified power and encoder connectors | Bench-verify the intended command mode first; treat as another machine's parts |
| Stored Allen-Bradley N-series set | Motor and drive matched by design | Years unpowered; bus capacitors need reforming | Bench-evaluate only if the schedule justifies the reforming work |
Install and commission the matched sets #
- Lock out the cabinet per your energy-control procedure — 29 CFR 1910.147 in US shops — and wait the bus-discharge time the drive manual states before touching terminals; drive bus capacitors hold a lethal charge after power-off.
- Record the LinuxCNC scaling, command polarity, encoder direction, enable behavior and axis travel limits, and save each old drive's parameters, before disconnecting anything.
- Read every nameplate and pull the datasheet for the exact part; where a nameplate and its datasheet line disagree, the physical label wins until the maker's document settles it.
- Fit the new X motor and check the body, connectors and cable bend radius clear the Y ways across the full restored travel. When the replacement shaft diameter differs from the old bore, as it usually does when the frame changes, specify a flexible shaft coupling to match the new shaft diameter at the same time.
- Commission one axis at a time: verify encoder counts and direction at low motion, then command polarity, then a stable enable cycle, before raising speed. Expect to tune each axis on its own; one write-up of tuned axes shows why the velocity gain factor varies from axis to axis.
- If a newly installed drive powers up but the ready signal the controller waits for never arrives, work through the diagnosis for a missing drive-ready signal on a retrofitted axis before changing parameters.
- Test each axis across its full travel and under cutting load, and accept the machine when Y and Z hold their cuts and X reaches the restored travel without interference.
The decision #
Size every axis on the continuous curve at the speed the cut runs, and let the peak badge cover acceleration only. The Fanuc motor comes off X regardless: no datasheet turned up for it, so its figure was never a verified rating, and the body caps the travel.
The dead Ultra 100 units do not come back as donors for different motors, and neither the X drive moving to Y nor the Ultra3000i going onto Z is a drop-in; each pairing is unverified exactly where drives fail: feedback, commutation, configuration. The repair that touches everything once and pairs nothing unproven is new matched motor-drive sets on all three axes, keeping the analog command architecture only if the chosen drives hold a stable axis on it, commissioned one axis at a time. The DMM and stored Allen-Bradley sets stay on the bench as inventory until each proves its command mode and its bus on a test stand — not as machine parts.
Questions asked
What does the S2 rating next to S1 mean on a servo datasheet?
S2 is short-time duty: the motor runs at the stated torque for a stated number of minutes, then rests long enough to return to ambient temperature. It is a sprint rating like peak torque, just a longer sprint. Size the axis on S1, and treat S2 as a limit for indexing moves and short cuts, never for a pass that runs continuously.
How long can a servo drive hold peak torque?
Only for the time the drive's overload curve allows. The manual states that curve as a torque multiple with a duration, and the durations are usually seconds rather than minutes. Run past it and the drive trips on overcurrent, which is why the sizing number is the continuous rating and peak covers acceleration and momentary overload only.
Is it safe to power up a servo drive that has sat unpowered for years?
Treat it as untested until the bus capacitors are reformed. Aluminum electrolytic capacitors lose oxide over years without voltage applied, and full power into a dried capacitor can fail it hard. Drive makers publish reforming procedures that raise the bus voltage gradually on a current-limited supply; follow the procedure for the exact drive and bench-test it before it goes on the machine.
Can new motor-drive sets keep the existing analog command wiring?
Usually yes, but re-verify the pair. Check the new drive's command input range against the controller's output range and redo the scaling, since a different full-scale voltage shifts every axis gain. If the new drive takes a torque command instead of a velocity command, the velocity loop moves into the drive and must be tuned there. Confirm the mode in the drive manual before wiring.