What a servo motor needs to hold torque at 7,500 rpm
Short answer
A 100 oz-in load held at 7,500 rpm is about 0.74 hp (0.55 kW) of continuous shaft power, so pick the motor from the continuous region of its torque-speed curve at that speed and the drive from the continuous current that torque implies over the duty cycle. Rated maximum speed and feedback rating close the check.

On this page
A servo motor for this job is selected at the operating point, not from the nameplate: the load is 100 oz-in (0.706 N·m) of torque that must still be available at 7,500 rpm, which works out to about 0.74 hp of continuous shaft power if the torque really is continuous. That one conversion sets the whole selection. The motor's continuous torque-speed curve must hold the load torque at the target speed, the drive must carry the continuous current that torque implies over the real duty cycle, and the feedback device must itself be rated for the speed. A maximum-speed label proves nothing under load. The arithmetic, the datasheet checks and the decision for each duty case follow.
What the operating point demands #
Torque and speed are not independent requirements. Shaft power rises with both, so the same torque that a small motor shrugs off at a few hundred rpm becomes a substantial machine load when it must be held at the target speed. The table is the complete list of numbers the two datasheets must cover for this operating point, and where each one comes from.
| Check | What this load asks for | Where the number comes from |
|---|---|---|
| Load torque at the motor shaft | 100 oz-in, present continuously | Measured or calculated from the load, including any ratio and its efficiency |
| Speed at that torque | 7,500 rpm, sustained | The machine cycle, not the motor datasheet |
| Shaft power | 0.74 hp while the torque holds | Calculated from torque and speed, as shown below |
| Motor continuous torque at that speed | At least the load torque | Continuous region of the motor's torque-speed curve |
| Motor peak torque | Covers acceleration, for the time the curve allows | Peak region of the same curve |
| Drive continuous current | The current the load torque implies over the whole cycle | Drive continuous rating versus the duty-cycle calculation |
Duty moves the thermal half of the selection. Motor heating follows current squared, so a torque held for half the cycle is thermally like a continuous torque about 29 percent lower — multiply the load torque by the square root of the duty fraction to get the continuous-equivalent value. That is a calculated approximation for a constant-torque duty, and it only holds if every peak stays inside the peak region for the time the curve allows. If any row above is unknown, measure or calculate it before comparing motors; the duty assumption moves the result more than any other input.
The motor: torque at the target speed, not maximum speed #
A servo motor's torque-speed curve has two regions: a continuous region the motor can occupy indefinitely, and a peak region it may enter only for a stated time. The rule is exact. If the duty is continuous, the point "load torque at the target speed" must sit inside the continuous region; if the duty is intermittent, the point may sit in the peak region but only for the permitted time. The rated maximum speed is a separate mechanical limit, shared with the feedback device, and it must clear the target speed with a margin you set deliberately — the same margin logic as in checking servo speed margin for a rack-and-pinion axis.
The common trap is reading the maximum-speed figure as a loaded capability. A motor that spins to the target speed unloaded may still fall short the moment torque is demanded, whether because the operating point sits outside the curve or because the drive runs out of voltage at speed; if that symptom appears, the likely causes and their checks are laid out in why a servo axis never reaches its commanded speed.
As a rule of thumb, smaller brushless servo frames more often carry rated maximum speeds above this figure than large frames do, but an expectation is not a rating — the datasheet of the exact frame size decides.
The drive: continuous current and duty, not horsepower #
The drive's job at this operating point is to produce the current the torque requires, at the required speed, for as long as the cycle requires. Check four things against your cycle: continuous current, which is the thermal limit; peak current, which is short-time with a stated duration; the feedback devices the drive explicitly supports; and whether the drive can still make that current available at the target speed at the lowest supply voltage your installation will see. The conversion from torque to current is one division by the motor's torque constant, worked through step by step in how to calculate servo motor current from required torque.
Horsepower labels are where this selection goes wrong. Motor and drive horsepower figures are established differently by different manufacturers, and one installer's reported experience — a 3 hp motor that needed a 5 hp drive to run continuously — shows what happens when labels stand in for current ratings. The trap has a parallel with VFD-driven induction motors, where overspeeding a 22 kW motor to 75 Hz does not guarantee 25 kW, as why overspeeding a motor past base speed does not guarantee nameplate power explains. For the motor and drive in front of you, the honest comparison is a single line: the drive's continuous current versus the current your duty cycle demands.
Feedback closes the loop. At this speed class, a brushless permanent-magnet servo motor with a resolver or a high-resolution encoder is the architecture that fits, and the drive must list support for that exact feedback type — the same compatibility questions as deciding whether an old servo motor can run on a new drive.
Worked example: from torque and speed to shaft power #
The inputs are an illustrative example: the load torque is 100 oz-in, continuous, at the motor shaft; the target speed is 7,500 rpm; direct drive, no reducer.
- Convert torque: 100 oz-in ÷ 16 = 6.25 lb-in, and 6.25 lb-in × 0.112985 N·m per lb-in = 0.706 N·m. In the horsepower formula's units, 6.25 lb-in ÷ 12 = 0.521 lb-ft.
- Convert speed: 7,500 rpm × 2π ÷ 60 = 785.4 rad/s.
- Shaft power: P = T × ω = 0.706 N·m × 785.4 rad/s = 555 W, about 0.55 kW. Cross-check with the horsepower form, P (hp) = torque (lb-ft) × rpm ÷ 5,252: 0.521 × 7,500 ÷ 5,252 = 0.74 hp. The two routes agree, as they must.
This is a calculated example for these inputs, not a measured result. Decision for this case: the motor's continuous curve must show at least 0.706 N·m at the target speed, and the drive's continuous current must cover what that torque implies through the torque constant for the whole cycle.
If the torque is specified at the load rather than at the motor shaft, redo the motor-side numbers through the transmission. Example: a 2:1 reducer at 90 percent efficiency in line, with the stated torque specified on the load side. The motor must then produce 55.6 oz-in (0.392 N·m) — the load torque divided by 2 × 0.90 — while turning at 15,000 rpm (1,570.8 rad/s), twice the target speed. Motor-side power = 0.392 N·m × 1,570.8 rad/s = 616 W, which is more than the 555 W reaching the load; the reducer dissipates the difference. A reducer trades motor torque for motor speed, never shrinks the power demand, and adds a requirement of its own: the motor's rated maximum speed must clear 15,000 rpm, not just the target speed.
A selection procedure on two datasheets #
- Fix the operating point in writing: torque at the motor shaft, speed at that point, and the duty — continuous, or seconds on and off per cycle, with acceleration and deceleration times.
- Convert torque and speed to one unit system and compute the shaft power with P = T × ω, as in the worked example.
- On the motor datasheet, confirm the operating point sits in the continuous region of the torque-speed curve, the rated maximum speed clears the target speed with margin, the peak region covers the acceleration torque for the time your cycle needs, and — where the manufacturer publishes one — the permitted load-inertia ratio.
- Divide the continuous torque and the peak torque by the motor's torque constant to get continuous current and peak current.
- On the drive datasheet, confirm continuous current at or above your cycle's RMS demand, peak current at or above your peak for its duration, explicit support for the motor's feedback device, and adequate output at the lowest expected supply voltage.
- Check the rating conditions — mounting, ambient temperature, cooling — and apply the manufacturer's derating wherever your installation differs from the documented conditions.
Prove it on the machine #
Sizing ends with one controlled run. Execute the real duty cycle and log actual speed, motor current and the time spent in each segment; compare the logged continuous segment against the drive's continuous rating, and watch for a temperature still climbing at cycle end or an overload indication — either one means the duty assumption was wrong, not the test. Change one sizing variable at a time and repeat the identical cycle until the logs sit inside the ratings.
The shaft joint is part of this check: at the target speed it must be balanced and rated for speed as well as torque, so when you specify the connection between the motor and the driven shaft, choose a flexible shaft coupling whose own datasheet ratings cover the operating point.
Safety note: guard the rotating joint before any loaded run at this speed — an unbalanced coupling or a loose set screw releases destructive energy at such revs — and keep the machine's own risk assessment and lockout procedure governing while you test.
The decision for each case #
- Torque continuous at the motor shaft, as stated: select the brushless servo whose continuous torque-speed curve holds the load torque at the target speed, with a rated maximum speed above it by a margin confirmed against the drive's output at your lowest supply voltage; size the drive by continuous current over the cycle, never by horsepower. The shaft power demand is the value computed in the worked example.
- Torque intermittent: the same operating point can fit a smaller continuous rating when the RMS over the cycle — the load torque times the square root of the duty fraction — stays inside the continuous region, and each peak stays inside the peak region for its permitted time. Confirm with the logged run.
- Torque specified at the load through a reducer: recompute the motor-side torque and speed with the ratio and efficiency, expect the motor-side power to rise by the losses, and check the motor's rated maximum speed against the multiplied speed first — that limit fails more often than the torque check at these speeds.
Every branch ends the same way: two datasheets, one curve check, one current check, decided at the operating point.
Questions asked
How do I turn the load torque into a continuous current figure for the drive?
Divide the torque at the shaft by the motor's torque constant, published on the motor datasheet. For example, with a torque constant of 0.30 N·m per ampere, holding 0.706 N·m takes about 2.4 A continuously, and acceleration takes proportionally more within the drive's peak rating. Read the constant from the datasheet of the exact frame size, because it varies widely between motors.
Is a speed of 7,500 rpm ordinary for a servo motor?
It sits at the high end for general-purpose servo motors but is routine for small brushless frames and spindle-class machines. The deciding number is the rated maximum speed on the datasheet of the exact frame size, and the feedback device's own speed rating must clear it too. Larger frames more often top out below this figure, so verify rather than assume.
Can a stepper motor do this job instead of a servo?
At a target speed this high, most steppers are far past the flat part of their torque curve and deliver only a small fraction of their holding torque, so the margin for a real continuous load is thin. Check the pull-out torque of the exact stepper at this speed before considering one; for a load that must be held steadily, a brushless servo is the dependable choice.
What feedback should the motor carry at this speed?
A resolver or a high-resolution incremental encoder suited to the mechanical speed, supported explicitly by the drive. Check three ratings: the feedback types and signal formats the drive lists, the feedback device's own maximum mechanical speed, and the resolution the control loop needs at that speed. A feedback device rated below the operating speed fails no matter how strong the motor is.