Comparison
Brushless servo motor: encoder or resolver choice
Short answer
Choose between a resolver and an encoder on the complete motor-drive-feedback system: a 12-bit resolver-to-digital conversion yields 4,096 absolute positions per revolution (0.0879 degrees) and rotor angle at power-up, while an incremental encoder quantizes more finely but needs Hall sensors or a phasing move before commutation. Decide on power-up position, quantization, vibration and the drive's command interface — not the biggest pulse count.

On this page
- Does a resolver know the rotor angle at power-up?
- How fine is a 12-bit resolver conversion, in degrees?
- Can encoder pulses per revolution be compared with resolver bits?
- Does an incremental-encoder motor need Hall sensors or a phasing move?
- Which feedback tolerates vibration on a machining axis?
- Does resolver feedback remove homing on a linear axis?
- Resolver or encoder when a PLC or motion controller commands the drive?
- Which feedback should you actually buy?
- Questions asked
Choose feedback for a brushless servo motor by matching the complete motor-drive-feedback system to the machine, not by taking the biggest number on a datasheet. A resolver read through a 12-bit resolver-to-digital conversion hands the drive an absolute rotor angle within one revolution the moment power comes up; an incremental encoder distinguishes finer angles but needs Hall sensors or a phasing routine before the drive can commutate. Four quantities decide the choice: position at power-up, effective angular quantization, the vibration the axis lives with, and the command interface between drive and controller. This article puts both feedback types on one positions-per-revolution basis, works the arithmetic, and ends with a decision for each case.
Does a resolver know the rotor angle at power-up? #
Yes, within one mechanical revolution: the resolver's sine and cosine outputs carry the rotor angle as amplitudes, so a drive with a resolver-to-digital converter reads an absolute angle the instant power comes up, with no phasing move and no commutation sensors.
A resolver is an electromagnetic transducer built into the motor. The drive energizes it with an excitation signal, and the two return channels carry amplitudes proportional to the sine and cosine of the shaft angle; a 12-bit converter such as the AD2S1200 digitizes those two channels with a pair of A/D converters feeding a tracking loop, exactly as its datasheet describes. Direction comes from the way the computed angle changes over time. Because the reading is regenerated from shaft physics rather than a stored count, the same absolute angle is available again after every power-off, which is why a resolver can serve as absolute position feedback after power-off for an axis that must report where it stopped.
The excitation frequency and signal levels are matched between motor and drive, which is one reason a resolver motor is specified together with a drive family that documents its feedback. Nothing on the resolver side stores a position word, so there is no battery, no count memory and no startup phasing to maintain.
How fine is a 12-bit resolver conversion, in degrees? #
A 12-bit converter divides one revolution into 2^12 parts, that is 4,096 distinct positions, which is 360 degrees divided by 4,096, or 0.0879 degrees — about 5.27 arc-minutes — per feedback step.
The step follows from the word length: 2^12 codes spread evenly over one mechanical revolution of a single-speed resolver, the same worked example the converter literature uses. Two cautions attach to that number. It is the quantization of the conversion, not the sensor's accuracy; accuracy is a separate datasheet line and is not implied by the step count. And it holds for a single-speed resolver: a multi-speed resolver repeats its electrical cycle within one mechanical revolution, so its positions-per-revolution figure changes with the speed count and comes from the motor datasheet. The conversion stage itself is standard off-the-shelf silicon — the AD2S90 digitizes resolver signals with no external components, per its datasheet — and encoder product lines are quoted in bit depth too, with capacitive encoder families offered in 12-bit and 14-bit options, so the step belongs to the converter's word length rather than to any one vendor.
Can encoder pulses per revolution be compared with resolver bits? #
Not on their own: convert both quotes to positions per revolution first, because a quoted "17-bit, 16,384 pulses per revolution" spec pairs a number that means 131,072 values with a count that means 2^14 — two different stages described in two different conventions.
A full 17-bit position word holds 2^17 = 131,072 distinct values; 16,384 distinct positions is 2^14. When one quotation carries both figures it is describing two stages of the chain — most likely the converter's word and the counted pulses — or one of them is loose, so ask which quantity the drive's position word actually contains. The table puts the common quotes on one basis.
| Quoted quantity | What it counts | Positions per revolution | Angular step |
|---|---|---|---|
| 12-bit conversion word | 2^12 codes | 4,096 | 0.0879 degrees |
| 14-bit position word | 2^14 codes | 16,384 | 0.0220 degrees |
| 16,384 pulses/rev, four-edge decode | 16,384 cycles × 4 edges | 65,536 | 0.00549 degrees |
| 17-bit position word | 2^17 codes | 131,072 | 0.00275 degrees |
Pulse-count conventions differ as much as the words do. On the convention where each edge of a square wave counts as one pulse, a 12-bit conversion is quoted as the equivalent of an 8,192-pulse encoder: two edges per position step double the count to 8,192 transitions per revolution. On a four-edge convention the same spacing is quoted as cycles and decodes to four times as many counts. Convert every quote to positions per mechanical revolution, and after any drive or feedback change re-derive the scaling from feedback counts to load travel — travel that comes out wrong after a servo drive swap with a 22-bit encoder usually starts exactly there.
Worked example, calculated for these inputs and not measured: a single-speed resolver with a 12-bit conversion gives 4,096 positions per revolution at the motor; the ball screw has a 5 mm lead and couples 1:1 with no gearbox. Arithmetic: 360 degrees / 4,096 positions = 0.0879 degrees per step, and 5 mm × 0.0879 / 360 = 0.00122 mm of load travel per step. The same screw with the table's 16,384-position word gives 5 mm × 0.0220 / 360 = 0.000306 mm per step. Both results sit far inside an example ±0.01 mm positioning target, so at this transmission quantization does not decide the choice; screw pitch error, backlash and following error set what the machine can hold.
Does an incremental-encoder motor need Hall sensors or a phasing move? #
Yes: at power-up an incremental encoder reports only movement since startup, so the drive must learn the rotor's commutation angle from Hall-effect sector sensors or from a documented alignment routine before it can run the motor.
An incremental encoder counts transitions from an arbitrary datum; it knows that the shaft moved, not where it stopped. Three Hall sensors spaced 120 electrical degrees apart identify six commutation sectors per electrical revolution — coarse, but enough for the drive to energize the correct stator phases at startup and refine the angle from there. Where Hall sensors are absent, the drive runs a documented phasing routine at startup to learn the commutation offset, and some drives repeat the calibration at every power-up — the behavior behind why a servo calibrates again after every power cycle.
Read what that routine does before accepting such a motor for a constrained axis. If it rotates the shaft to find the offset, a clamped fixture or a braked vertical axis moves with it; that first alignment move is a motion hazard like any unexpected start, so treat it within the machine's risk assessment and keep the area clear during commissioning. The decision: an axis that must not move at power-up takes resolver feedback or an absolute encoder, not an incremental encoder whose startup depends on a phasing move.
Which feedback tolerates vibration on a machining axis? #
On a machine that cuts metal, shortlist the resolver first as a rule of thumb: its rotor sensing is copper windings and laminated steel built into the motor, while an encoder adds a code disk with optics and electronics in one small package that shock and vibration must spare.
The reasoning is construction. A resolver's sensing elements are part of the motor's electromagnetic structure, with no disk to crack and no optical or electronic subassembly at the tail of the motor, where frame vibration arrives most directly. Construction is not a rating, though: the deciding document is the vibration and shock rating of the complete motor-feedback assembly on each candidate's datasheet, read at your mounting and temperature conditions. The decision follows: on machining axes and any frame with strong cutting vibration, shortlist resolver-feedback motors and then confirm the assembly ratings; on a smooth indexing or conveyor axis, treat vibration as a tiebreaker and rank the candidates on power-up position, quantization and interface instead.
Does resolver feedback remove homing on a linear axis? #
No: a single-speed resolver is absolute only within one revolution, so a linear axis driven through a 5 mm lead screw can sit at many load positions that all read the same rotor angle, and you still home the machine to its datum.
The resolver knows where the shaft sits inside its turn and nothing about the turns before it; the load repeats the same set of rotor angles once per revolution of screw travel. Multiturn absolute encoders retain the revolution count across power-off with a mechanical turn-counting gear or battery-backed electronics; single-turn devices, the resolver included, do not. So "absolute" alone never removes homing: classify the device as single-turn or multiturn, and note that a single-turn absolute encoder loses position on a linear axis for precisely the same reason. The companion comparison of absolute versus quadrature encoders and what survives a power cycle covers the encoder side of that question. The decision: a rotary axis that turns many times between references and must reposition after power-off needs a multiturn absolute encoder; a linear feed axis whose startup datum move costs a few seconds is well served by a single-turn resolver.
Resolver or encoder when a PLC or motion controller commands the drive? #
Match the feedback to where the position loop lives: a smart drive that runs the motion itself needs only the resolver, while a drive commanded with pulses and an analog torque reference from a PLC or motion controller must also export position, usually as an emulated encoder signal.
In that second architecture the loops split: trajectory and interpolation in the controller, commutation and torque in the drive, and the drive still needs rotor angle from its own feedback either way — which the resolver supplies without any extra element. What the controller adds is the need for a position signal. Many resolver drives document an emulated encoder output computed from the resolver angle, and it carries exactly the resolver's quantization, nothing finer; where the drive documents no such output, the alternatives are a physical encoder on the motor or an external encoder on the machine, with the extra sensor, cabling and mounting that implies.
The command interface — pulse and direction, analog reference, fieldbus setpoints — must match between controller and drive regardless of feedback type, so an incompatible interface is never cured by swapping the sensor. If the motion controller is a PC mounted in the control cabinet beside the drives, this is the point where you specify a fanless industrial mini PC for the motion role, sized with the feedback and command cards the axis count needs. Drive-side matching is its own selection step; what decides a drive for a resolver-feedback AC servo motor walks through it in detail. The decision: drives that hold the motion logic run well on resolver feedback alone; a PLC-controlled axis needs the emulated-output option confirmed in the drive documentation before a resolver motor is ordered.
Which feedback should you actually buy? #
Buy the resolver-feedback motor when the drive closes the position loop, the axis sees vibration, and a 12-bit conversion's quantization (0.0879 degrees) is inside the positioning tolerance; buy the encoder motor when you need finer steps, multi-turn absolute position, or a native encoder interface your controller already speaks.
| Your situation | Feedback that fits | Why it decides |
|---|---|---|
| Drive runs the motion logic; cutting vibration on the frame | Resolver with a 12-bit conversion | Absolute rotor angle at power-up; winding-and-steel sensing |
| PLC or external controller closes the position loop | Resolver plus a documented emulated encoder output, or an encoder motor | The controller needs a position signal the drive exports |
| Position must survive power-off across many turns | Multiturn absolute encoder | A single-turn device forgets the turn count |
| Required step finer than the 12-bit quantization | High-resolution absolute or sine/cosine encoder | The converter's word length sets the floor |
Ranked on those four quantities, the resolver wins most machine-building cases: it starts absolutely, its sensing survives the shop floor as well as its datasheet says, and its quantization clears the tolerance of most screw- and belt-driven axes at practical leads. The encoder wins when the machine genuinely needs its finer quantization or its multi-turn memory, and that choice brings Hall sensors or a phasing move at startup. The same logic at small frame sizes is walked through for 0.7 kW-class resolver-feedback axes, and the drive-matching checklist behind it applies to either feedback type.
Questions asked
Can a brushless motor carry both a resolver and an encoder?
Yes, and in many motors the encoder half is an emulated output computed in electronics from the resolver angle rather than a second sensing element; other motors mount both as physical devices. Check the motor's feedback option list and the drive's emulated-output feature before specifying two feedback channels the application may not need.
Does higher feedback resolution make the axis more accurate?
No. Resolution is the smallest angle the feedback can distinguish; accuracy is how close that reading lies to the true angle, and it is specified separately. Backlash, ball-screw pitch error, compliance and tuning dominate machine accuracy long before a feedback step of this size does, so compare the two datasheet lines independently.
How much angle do Hall sensors actually see?
Three Hall sensors spaced 120 electrical degrees apart identify six commutation sectors per electrical revolution. That is enough for a drive to start the motor and refine the angle from there, but it is far too coarse for positioning and gives no useful angle information beyond the sector boundaries.
Can a resolver motor run on a drive built for encoder feedback?
Not without a matching interface. A resolver needs an excitation output and a resolver-to-digital front end, while an encoder input expects pulse or sine/cosine signal levels the resolver does not produce. Select a drive family that documents resolver support for that motor and match connector, cable and scaling in the same step.
What does an emulated encoder output from a resolver actually carry?
Exactly the information the resolver conversion contains. An emulated quadrature signal computed from a 12-bit conversion cannot report finer than 4,096 steps per revolution, so an external controller reading it sees the resolver's quantization, not a high-resolution encoder's. When the external controller needs finer position, the machine needs a physical high-resolution encoder.