Pneumatics and hydraulics Published 9 min read By AutomateDirectUSA engineering team

Short answer

A shaft-driven pump throttled by a continuously rated relief valve works as the auger brake. At 5000 N·m and 165 rpm the shaft delivers a calculated 86.4 kW, so displacement, valve and cooler must be selected as one heat-rejection system of about 90 kW for 1-2 h, with a torque transducer because pressure alone is not torque.

On this page
  1. How much braking power must the pump absorb?
  2. How do you turn those numbers into pump displacement and flow?
  3. Can a relief valve really be the brake, and what must it survive?
  4. Where does the absorbed energy go, and how big must the cooler be?
  5. Which pump type suits a slow shaft-driven absorber?
  6. When does an electrical alternative beat the hydraulic brake?
  7. How do you prove the load the auger actually felt?
  8. Questions asked

The right brake for the stated auger test is a shaft-driven fixed-displacement pump feeding a continuously rated, adjustable relief valve, because the numbers decide it: 5000 N·m at 165 rpm is a calculated 86.4 kW of shaft power, and every watt of it becomes heat in the oil. That makes pump displacement, valve duty and cooler capacity one selection problem, not three.

This article works through that selection with the stated test parameters: a 5000 N·m maximum torque, the stated 90 kW maximum power, 1-2 h of continuous testing, and load points at 20, 40, 60 and 80 percent of maximum power. The auger is itself driven by a hydraulic motor and the whole drivetrain, motor included, is under test, which is exactly why the load absorber should be a separate hydraulic circuit bolted to the shaft end rather than the drive unit reused as a brake.

How much braking power must the pump absorb? #

Shaft power sets the absorber size, and at the stated torque and speed the calculated power is 86.4 kW, close to the stated maximum. Size the pump, valve and cooler against the 90 kW stated maximum, then treat 86.4 kW as the cross-check that the three ratings describe one consistent operating point rather than three separate maxima.

The calculation is torque times angular speed:

P = T × 2πn / 60 = 5000 N·m × 2π × 165 rpm / 60 = 86,395 W ≈ 86.4 kW

Conversely, delivering the full stated 90 kW at the target rate requires 90,000 / 17.279 = 5208 N·m. The roughly 4 percent gap between 5208 N·m and the stated torque probably reflects rounded ratings or a maximum that does not occur at maximum speed; for a test stand, define the test points explicitly instead of chasing it.

The requested 20, 40, 60 and 80 percent points need a declared reference too. Take them as percentages of the 90 kW stated maximum at fixed shaft speed:

Test point Brake power Required torque at the target rate Energy over 1-2 h
20% 18 kW 1042 N·m 18-36 kWh
40% 36 kW 2083 N·m 36-72 kWh
60% 54 kW 3125 N·m 54-108 kWh
80% 72 kW 4167 N·m 72-144 kWh
100% stated maximum 5208 N·m 90-180 kWh

Declare that reference in the test procedure. Percentages of the torque rating instead produce 17.3, 34.6, 51.8 and 69.1 kW at the same speed, and a customer comparing certificates will notice which convention you used.

How do you turn those numbers into pump displacement and flow? #

Pick a working differential pressure from component ratings first, then solve the torque equation for displacement. At an example 250 bar differential with a mechanical efficiency of 0.9, absorbing the full stated torque needs a displacement of about 1396 cm³/rev, and that pump at the target rate delivers roughly 219 L/min at a volumetric efficiency of 0.95.

The three equations, with units carried through:

  • Torque: T = Δp × D × ηm / (20π), with T in N·m, Δp in bar, D in cm³/rev and ηm the mechanical efficiency.
  • Flow: Q = D × n × ηv / 1000, with Q in L/min, D in cm³/rev, n in rpm and ηv the volumetric efficiency.
  • Hydraulic power: Phyd = Δp × Q / 600, with Phyd in kW, Δp in bar and Q in L/min.

Worked example (illustrative inputs, not a measured result): with Δp = 250 bar and ηm = 0.9,

D = T × 20π / (Δp × ηm) = 5000 × 62.83 / (250 × 0.9) = 1396 cm³/rev

Then at n = 165 rpm with ηv = 0.95:

Q = 1396 × 165 × 0.95 / 1000 = 219 L/min

and the circuit's hydraulic power is Phyd = 250 × 219 / 600 = 91.2 kW. That point sits just above the calculated 86.4 kW shaft power because the example efficiencies are losses the drive motor must also supply; the exact ratio depends on the candidate pump's datasheet, so take ηm and ηv from the datasheet of the exact part at your pressure, speed and oil viscosity, not from this example. If 250 bar pushes the displacement into an impractical size, raise the pressure rating; displacement falls in direct proportion.

The same discipline applies elsewhere in the stand when pressure acts on an area, as the bore-sizing calculation in sizing a hydraulic cylinder bore for a linked lift shows for a lift circuit: state pressure, area and efficiency separately, then multiply.

Can a relief valve really be the brake, and what must it survive? #

Yes: an adjustable relief valve is a controllable restriction, and the pressure it holds times the pump displacement is your applied torque. The catch is duty. Most relief valves in mobile and industrial circuits are sized for occasional overpressure events; continuous throttling at full stated power is a heat-dissipation duty, so select a valve whose datasheet explicitly permits continuous flow at the working pressure and flow, not one whose catalogue lists only a cracking pressure and a max spike rating.

Retain a separate protective relief path set above the load-control valve, so a stuck or failed control valve cannot overload the pump, the hoses, the shaft coupling or the auger gearbox. That protective valve still needs a continuous-dissipation rating at its own pressure-flow point, because when it opens in anger it dumps the full flow. The principle is the same one behind protecting a drive shaft from motor torque overload: the overload path must have its own rated release, not the operator's attention.

Protecting an auger shaft from motor torque overload

Keep the suction path short and generously sized, because at 165 rpm the pump runs far below the speed most pump curves assume. Verify the pump datasheet's minimum speed, permitted inlet pressure, viscosity range, case-drain requirement and rotation direction before ordering anything. Low inlet pressure causes cavitation and unstable torque, and excess return-line backpressure adds directly to the differential pressure, which means it adds directly to brake torque you did not command.

Where does the absorbed energy go, and how big must the cooler be? #

Nearly all absorbed power ends up as heat in the oil, so the cooler must reject the steady absorbed power, not an average. At the 80 percent point the circuit rejects about 72 kW continuously, 144 kWh over a two-hour test; at full stated power the duty is 90 kW and 90-180 kWh per test. Size the heat exchanger for the full power plus circuit losses at your worst ambient, with margin for cooler fouling.

A water/oil cooler rejects that load compactly where a suitable water supply exists. An air/oil cooler works too but needs a much larger core and dumps the entire heat load into the test cell unless you duct the exhaust elsewhere; at full load that is a real HVAC question, not a fan choice. Control oil temperature actively, because viscosity shifts change leakage, valve behavior and pressure drop, which changes applied torque at a fixed valve position; read the permitted temperature and viscosity windows from the pump and valve datasheets and hold the oil inside the overlap. The same viscosity-driven behavior shows up as noise and heat in service machines, as described in the article on why a hydraulic system hums under load at full speed.

A large reservoir does not solve this. It delays the rise but cannot reject heat, so treat reservoir size as a suction and deaeration decision and put the money into cooler area.

Which pump type suits a slow shaft-driven absorber? #

A gear pump is the sensible starting point at this speed, as it tolerates low speeds well and is simple to mount on the auger shaft line, but select by datasheet, not by type. Check the candidate's minimum continuous speed, low-speed volumetric efficiency, continuous pressure, side-load rating on the shaft, and lubrication requirements. Vane and piston units can also work and may give smoother pressure ripple or higher continuous pressure, which lets you use less displacement for the same 5000 N·m, but their low-speed leakage behavior must be confirmed at the target rate.

Whatever the type, decide the primary selection question first: where the energy goes. That choice, not the pump brand, decides the architecture.

When does an electrical alternative beat the hydraulic brake? #

Choose electrical absorption when the energy bill or the cell heat load dominates: a braking resistor bank still converts everything to heat, while a regenerative drive returns most braking power to the supply. A hydraulic absorber converts everything to oil heat, which you then pay to move outside, so for a one-off or low-rate prototype investigation like this one the hydraulic route's simplicity and your own hydraulic competence win; for daily production testing of many units, regeneration usually pays back.

Approach Energy destination Main advantage Main design burden
Pump plus throttling valve Oil heat Direct pressure-based loading; fits hydraulic expertise Continuous-duty valve, cooler, reservoir, viscosity control
Induction machine plus resistor bank Resistor heat Established dynamometer practice Generator control, resistor sizing, heat exhaust
Regenerative drive Mostly returned to supply Small sustained heat rejection Higher first cost, electrical integration
Packaged dynamometer brake Depends on type Integrated load control and measurement Selection and mechanical integration

How do you prove the load the auger actually felt? #

Measure torque and speed directly in the shaft line, because pressure alone is not torque. Fit a torque transducer and a speed sensor, compute shaft power as T × 2πn / 60 at every point, and log it with pump inlet pressure, outlet pressure, actual flow and oil temperature. Comparing the shaft power against the calculated hydraulic power Δp × Q / 600 reveals absorber efficiency, measurement faults and temperature drift in one number.

Record oil temperature with every test point: a cold circuit and a hot circuit can produce different torque at the same valve position, and a certificate that omits temperature will not reproduce. Ramp the load-control valve slowly through the 20-80 percent points so the loop, not the operator's hand, sets the gradient, mirroring how soil resistance builds as the auger digs. Before the first loaded run, verify the rotating assembly the way high-speed rotating cylinders are verified, with coupling balance, bearing speed limits and shaft critical speed checked for continuous duty at the target rate.

The decision: build a separate hydraulic absorber on the auger shaft end - a fixed-displacement pump sized for the stated torque at the target rate at your chosen working pressure, a continuously rated adjustable relief valve as the load control, a second protective relief behind it, a cooler rated for the full steady heat load, and a torque transducer plus speed sensor as the only accepted measurement of applied load. Keep the electrical alternatives on the list for a future production-rate version of the stand.

Questions asked

Can any fixed-displacement pump work as a hydraulic brake?

Gear, vane and piston pumps all absorb torque when driven as pumps against a restriction, but the candidate must satisfy three datasheet limits at your test point: continuous pressure, minimum operating speed, and permitted inlet (suction) pressure. At 165 rpm, check the published minimum-speed and low-speed volumetric-efficiency figures carefully, because many pump datasheets assume 1200 rpm or more and a slow gear pump can cavitate or lose torque predictability.

Does a bigger reservoir keep the oil cool during the test?

No. A larger reservoir only delays the temperature rise; it stores heat, it does not reject it. During a 1-2 h continuous test at up to 90 kW absorbed, the heat exchanger must reject the full steady power at the actual ambient or coolant temperature, and the reservoir only needs enough volume for deaeration, thermal expansion and a stable suction head.

Why measure torque with a transducer if I already have pump pressure?

Because brake torque equals differential pressure times displacement times mechanical efficiency, and efficiency drifts with oil temperature and speed. At the same valve position a cold circuit and a hot circuit can apply different torque. A torque transducer and a speed sensor in the shaft line give the true applied load, and comparing shaft power with the calculated hydraulic power exposes losses and measurement faults.

Keep reading

  • Explainer

    Why a hydraulic pump command should follow the cycle, not the valves

    Own the pump run command in one place: a hydraulic-cycle demand set by the active sequence, released by a retriggerable off-delay just longer than the longest measured valve-command gap. Per-stage ANDs and a raw OR of valve outputs both drop the request during break-before-make transitions, so the pump stop-start cycles; the overrun bridges those gaps at the cost of relief heat.

    Pneumatics and hydraulics

  • Troubleshooting

    Why a Hydraulic System Hums Under Load at Full Speed

    Check the pump delivery hose first. A hydraulic hum that grows as the machine loads is pump pressure ripple meeting a line that no longer damps it: a smaller bore adds restriction and a stiff wall removes the compliant cushion that smooths each pulse. Restore the specified bore and a compliant construction before touching the relief valve, which is the second suspect.

    Pneumatics and hydraulics

  • How-to

    Sizing a VFD for a hydraulic pump fatigue test rig

    Size the pump's speed range by worst coincident peak flow, not average stroke volume: at 10 Hz a 3 mm peak-to-peak command needs 0.0942 m/s peak cylinder velocity, while 0.2 to 0.5 mm commands need only 6.7 to 16.7% of that flow. Size the drive for the motor's full-load current with 150% starting overload, and keep the relief valve as independent overpressure protection.

    Pneumatics and hydraulics