How-to
Stepper Motor Torque at Speed for a Web Tension Roller
Short answer
A 10 lbf web on a 3 in driven roller needs 240 oz-in of steady torque at about 255 RPM. A NEMA 34 curve that shows 100 oz-in there covers only 42% of the tension load, so read torque-speed curves at the operating speed — never the holding-torque rating — and either add reduction or move to a geared servo for a continuous tension zone.
On this page
- The check, step by step
- Steady torque from the web tension
- Roller speed from the line speed
- Read the curve at the operating speed, not at zero
- Worked comparison at the operating point
- What the steady torque figure leaves out
- If you keep a stepper, work the reduction arithmetic
- Supply voltage moves the curve
- The decision, case by case
- Verify it on the machine
- Questions asked
Your arithmetic is right, and the motor fails it. Ten pounds of web tension on a 3 in driven roller demands 15 lb-in — 240 oz-in — of steady torque at roughly 255 RPM for a 200 ft/min line. The NEMA 34 curve in this example reads about 100 oz-in at that speed: 42% of the tension load alone, before inertia, acceleration, friction, or clutch transients add anything. So read every stepper torque-speed curve at running speed, never at holding torque, and either put enough motor and reduction behind the roller to clear the curve with margin or move this axis to a geared servo. For a continuously loaded tension roller, the geared servo is the call.
The check, step by step #
- Confirm the tension the driven roller must hold and the roller diameter at the surface the web rides on.
- Compute the steady torque: T = F × r.
- Convert line speed to roller RPM from the roller circumference.
- Read the motor's pull-out torque curve at that RPM, for your exact motor, drive, and supply voltage.
- Add acceleration, inertia, friction, and disturbance torque on top of the steady value.
- If the curve does not clear the total with margin, change the ratio or the architecture and redo the reflected numbers.
Steady torque from the web tension #
The roller pulls against the tension the upstream clutch sets, so the load is tension times radius at the driven surface:
T = F × r = 10 lbf × 1.5 in = 15 lb-in
Converting to the units the curve uses: 15 lb-in × 16 oz-in per lb-in = 240 oz-in.
That figure is a calculated steady-tension requirement for these inputs. It contains nothing for bearing friction, roller inertia, acceleration, or the torque spikes a clutch can feed into the web — those are separate inputs you add on top.
Roller speed from the line speed #
Speed comes from the circumference:
v = 200 ft/min × 12 in/ft = 2400 in/min
C = π × 3 in = 9.42 in per revolution
n = 2400 in/min ÷ 9.42 in/rev = 254.6 rev/min
Use 255 RPM. That pair — the torque above at that speed — is the operating point, and it is the only point at which the motor curve means anything.
Read the curve at the operating speed, not at zero #
A stepper datasheet headline is holding torque: zero speed, full current. The curve is what the motor can actually do, and it falls continuously as speed rises. Two curves appear in the literature:
- Pull-in torque: what the motor can start against without a ramp. Irrelevant here — this roller runs continuously.
- Pull-out torque: what the motor holds while already running, the maximum slew torque. This is your number at the roller speed found above.
Two conditions go with it, both documented behavior of these motors: the curve is drawn for one specific motor, drive, and supply voltage, and once the motor is running its torque depends on drive type and supply voltage. A curve generated on a different drive or a lower supply is not your curve.
In the plotted example the NEMA 34 shows 100 oz-in at the operating speed against the 240 oz-in requirement. The motor covers 100 ÷ 240 ≈ 42% of the steady tension load, short by 140 oz-in. To merely tie the load it would need 2.4 times the torque it has — and tying is not sizing.
Worked comparison at the operating point #
| Quantity | Value | Basis |
|---|---|---|
| Steady tension torque | 240 oz-in (15 lb-in) | 10 lbf × 1.5 in, calculated |
| Roller speed | ≈ 255 RPM | 2400 in/min ÷ 9.42 in/rev, calculated |
| Motor torque at that speed | 100 oz-in | example curve input |
| Share of steady load covered | ≈ 42% | 100 ÷ 240 |
| Shortfall | 140 oz-in | 240 − 100 |
| Mechanical power at the roller | ≈ 45 W | 1.69 N·m × 26.7 rad/s |
The power check, since a 55 W estimate for these inputs runs high:
T = 15 lb-in × 0.113 N·m per lb-in = 1.69 N·m
ω = 255 rev/min × 2π rad/rev ÷ 60 s/min = 26.7 rad/s
P = 1.69 N·m × 26.7 rad/s ≈ 45 W
That last figure is the mechanical power leaving the roller for these inputs — a magnitude check, not motor electrical power and not a supply rating.
What the steady torque figure leaves out #
Four loads sit on top of the steady tension, none of them inside it:
- Acceleration torque: roller inertia times the angular acceleration of your worst speed change, worked through calculating servo axis acceleration for torque sizing.
- Friction: bearing and seal drag on the roller shaft.
- Reflected losses: any gear stage taxes the motor side by its inefficiency.
- Disturbance torque: clutch grab and web variation arrive as transients, and a stepper that meets a transient beyond its pull-out torque loses steps — silently.
If you keep a stepper, work the reduction arithmetic #
Reduction divides torque and multiplies speed at the motor. With a 4:1 stage at an assumed 0.95 efficiency (take the real number from the belt or gearbox data for the exact part):
motor torque = 240 oz-in ÷ (4 × 0.95) = 63 oz-in
motor speed = 255 RPM × 4 = 1020 RPM
A 2:1 stage asks 240 ÷ (2 × 0.95) = 126 oz-in at 510 RPM. In both cases the pull-out curve must clear the reflected torque at the reflected speed, plus the dynamic loads and margin.
Here is the trap: every step of ratio spins the motor faster, and stepper torque falls with speed. You cannot ratio your way out indefinitely — past some ratio the curve drops faster than the load divides. Staying direct-drive instead means a motor whose curve reads at least 360 oz-in at the roller speed, which is 1.5 × the steady load — the minimum margin worth designing to, as a rule of thumb. That is a much larger frame on a supply near the drive's maximum rated input.
Supply voltage moves the curve #
Because running torque depends on the drive and its supply, the most effective change you can make to a stepper's curve short of a bigger motor is supply voltage. Within the drive's rated input range, run the highest voltage allowed and read the curve drawn at that voltage. A curve generated at 24 V tells you nothing defensible about the motor at 48 V; do not extrapolate it.
The decision, case by case #
- Direct-drive stepper as plotted: no. 42% of the steady load, 140 oz-in short before anything dynamic.
- Bigger stepper at the roller speed: only if a published curve for that motor, on your drive and supply, reads 360 oz-in or better there. If no such curve exists in the range you can buy, drop this option.
- Geared stepper: arithmetically alive at 63 oz-in and 1020 RPM (4:1) or 126 oz-in and 510 RPM (2:1), but only if the curve clears those faster points with dynamic loads and margin added — and the falling-with-speed character of steppers caps how far this path goes.
- Geared servo: the right call for a continuously loaded tension roller. A servo holds torque at speed instead of shedding it, rides clutch transients without losing position, and the reflected-torque arithmetic above sizes it. The factors that decide this class of choice are laid out in what actually decides stepper versus servo torque, and the retrofit economics in when a stepper-to-servo conversion is worth it.
Before you run any web at tension, guard the in-running nip points the moving web creates and work through the machine's risk assessment; printing press safeguarding in the US is the subject of ANSI B65.1.
Verify it on the machine #
Whatever you choose, prove it at the corners: maximum tension at maximum line speed, the worst acceleration profile, and a cold start into a tensioned web. Mark the motor shaft and check the mark after a shift to catch lost steps, and log motor temperature, because a stepper pushed to its torque limit runs hot enough to shed more torque. If steps slip or the drive trips at any corner, the sizing answer was the bigger one.
Questions asked
Why is holding torque useless for this sizing?
Holding torque is measured at zero speed with full current in both phases. As speed rises, the drive has less time to build current each step — winding inductance sets that time constant — so available torque falls steadily along the pull-out curve. At the operating speed here a stepper typically delivers a fraction of its holding torque; the published torque-speed curve for your motor, drive, and supply voltage is the only number that counts.
How much does supply Voltage change the torque at speed?
A stepper's torque above a few hundred RPM depends strongly on supply voltage: raising the voltage shortens the current rise time each step, which pushes the knee of the torque-speed curve out to higher speed. The effect is only quantified on curves drawn at each voltage, so use the highest supply your drive's rated input range allows and read the matching curve. Do not extrapolate a 24-volt curve to a 48-volt supply.
Does the required torque change as a roll builds?
On an unwind or rewind, yes: torque equals tension times radius, so size those drives for maximum tension at maximum roll radius and check the minimum at core radius. The driven roller in this example has a fixed 1.5 in radius, which is why its steady-tension requirement stays constant across the speed range.
When is roller torque the tension difference rather than the full tension?
When the web enters and leaves a roller at different tensions, that roller sees only the difference: torque equals tension out minus tension in, times radius. A wrapped roller with equal tension on both sides carries load in the web but needs no net torque. Here the upstream clutch holds the web at 10 lbf and the driven roller works against it, so full tension times radius is the right requirement.
Can I size the power supply from the 45 W figure?
No. The 45 W is mechanical power at the roller: 1.69 N·m at 26.7 rad/s. The drive draws more than that once winding and drive losses, standstill current, and acceleration peaks are counted. Size the supply from the drive's rated current and voltage using the drive's own method, and treat 45 W only as the floor for the mechanical job.