What an asynchronous servo motor is: slip, torque and drive control
Short answer
An asynchronous servo motor is a high-performance squirrel-cage induction motor used as a servo axis: the stator field runs ahead of the rotor, and that slip induces the rotor currents that make torque. A vector-controlled drive with the right induction motor model and shaft feedback regulates speed and position to servo accuracy, without permanent magnets in the rotor.

On this page
- What is an asynchronous servo motor?
- How does slip create torque?
- How do you calculate synchronous speed and slip?
- Why does a servo drive use vector control on an induction motor?
- What data does the drive need to run an asynchronous servo motor?
- When does an asynchronous servo motor beat a permanent-magnet servo?
- What tests prove the axis is set up correctly?
- Questions asked
An asynchronous servo motor is a three-phase squirrel-cage induction motor engineered for servo duty — the 1PH7 and 1PH8 families are the familiar examples — and it makes servo-grade speed and position control without any magnets in the rotor. The two words answer different questions. Asynchronous names the operating principle: the rotor never keeps pace with the stator field, and torque comes from that lag, the slip. Servo names the job: a drive closing speed and position loops around shaft feedback. The high-performance cage construction supplies the fast torque response; vector control in the drive supplies the accuracy. Below are the slip and synchronous-speed formulas with a worked example, the control scheme that does the magnets' job, the drive data the setup needs, and the four tests that prove the axis.
What is an asynchronous servo motor? #
It is a three-phase squirrel-cage induction motor built for servo duty: the rotor carries conductive bars shorted by end rings instead of magnets, and a vector-controlled drive with shaft feedback gives it servo-grade speed and position control.
The two words describe different layers of the same machine. Asynchronous is the electromagnetic principle — the rotor runs out of step with the stator field on purpose, because that out-of-step motion is what induces rotor current. Servo is the application — a controller regulating speed or position against a feedback device. One motor can be both at once, and servo duty on the nameplate says nothing about the rotor containing magnets.
The rotor itself is the classic squirrel cage: a cylinder of steel laminations carrying aluminum or copper bars, all shorted together by end rings. What separates a servo-grade cage from a general-purpose IEC motor is the engineering around it — a lighter rotor for low inertia, a cage profile shaped for torque response, and cooling sized for repeated load changes. That construction raises the dynamic performance well above a standard induction motor without changing the principle it runs on: torque still requires slip.
How does slip create torque? #
Torque exists only while the rotor turns slower than the stator field: that difference — the slip — sweeps the field across the cage bars, induces current in them, and the bar current reacting with the field produces torque.
Write slip as s = (n_s − n_r) / n_s, where n_s is synchronous speed and n_r is rotor speed, both in rpm. At standstill under power, s = 1 and the motor develops its starting torque; as the rotor accelerates, slip shrinks and the machine settles where its torque curve meets the load. If the rotor ever reached synchronous speed, the bars would sit in an unchanging field, induce nothing and make no torque — zero slip means zero torque, which is why an induction rotor can never lock to the stator field the way a permanent-magnet rotor does.
The bars see the stator field at the slip frequency, s × f. Below the breakdown point, torque rises roughly in proportion to slip; beyond it, torque collapses, which is why the drive holds the operating point well clear. Under vector control, slip stops being an accident of the load and becomes a commanded quantity: the controller imposes exactly the slip frequency that the torque command calls for.
How do you calculate synchronous speed and slip? #
Calculate the stator field speed as n_s = 120 × f / P, with f the stator frequency in Hz and P the pole count — a 4-pole motor on a 50 Hz supply runs its field at 1,500 rpm.
The worked example is calculated for these inputs, not a measured result: a 4-pole asynchronous servo, 50 Hz supply, nameplate rated speed 1,440 rpm.
- Synchronous speed: n_s = 120 × 50 / 4 = 1,500 rpm.
- Rated slip: s = (1,500 − 1,440) / 1,500 = 60 / 1,500 = 0.04, a 4 percent slip.
- Slip frequency at the bars: s × f = 0.04 × 50 Hz = 2 Hz.
- Commanded shaft speed 1,000 rpm at rated torque: the slip speed is 0.04 × 1,500 = 60 rpm, so the field runs about 1,060 rpm and the drive outputs 1,060 × 4 / 120 ≈ 35.3 Hz while the encoder shows 1,000 rpm on the shaft.
- On a 60 Hz supply, the same 4-pole field turns 1,800 rpm.
Two habits follow. First, the nameplate pair — rated frequency and rated speed — is how the drive learns rated slip, so compute it before entering motor data. Second, use the same math as a live check: shaft speed in rpm times the pole count, divided by 120, gives the output frequency the axis would need with no slip, and the drive's actual output frequency sits one slip frequency above it.
Why does a servo drive use vector control on an induction motor? #
A vector-controlled drive treats slip as a command input rather than a side effect: it computes the rotor field angle from an induction motor model, splits stator current into a flux-producing component and a torque-producing component, and regulates each separately, so the motor answers a torque command like a servo.
A permanent-magnet servo drive reads the field angle straight from the feedback, because the magnets are fixed to the rotor. An induction drive must compute it: rotor angle from the feedback device, plus the accumulated slip position from the motor model. With flux held constant by one current component, torque follows the other component close to proportionally — that substitution of a computed field for a magnet-carried one is the whole trick, and it is why the motor model and its data are load-bearing parts of the control.
The closed loops sit on top: the speed loop compares command with shaft feedback and drives the torque reference, and the position loop wraps outside it. Position accuracy therefore comes from the feedback device, not from the rotor construction. Sensorless vector control can govern speed on general-purpose drives, but a positioning axis wants a shaft feedback device in the loop.
What data does the drive need to run an asynchronous servo motor? #
Set the drive's motor type to induction, enter the nameplate exactly — rated voltage, rated current, rated frequency, rated speed and, where the drive asks, rated power and power factor — and then run the drive's documented motor identification routine, which measures what the vector-control model needs.
Rated speed is the entry that teaches the drive its rated slip — synchronous speed minus rated speed, over synchronous speed — so a substituted speed poisons the torque model from the first move. Applying a permanent-magnet motor model to a cage rotor is not a harmless naming choice: the drive integrates the wrong flux equations, and the symptoms are immediate — current with little torque, speed that sags under load, torque limits that trip early. Take every value from the nameplate and the manufacturer's documentation for the installed execution.
Family names such as 1PH7 or 1PH8 start the documentation search but do not finish it, because cooling, winding and feedback hardware vary within a family. If your motor belongs to one of those two families, a comparison of the 1PH7 and 1PH8 servo motor families works through what separates them and what that changes at the drive.
Then confirm the feedback hardware: its type, electrical interface and assignment in the drive must agree with what is bolted to the shaft, and signal names between motor and drive do not always line up — matching encoder signal names between motor and servo drive covers the mismatches that look like drive faults.
Run the identification routine with the drive's protective functions active and the machine in its approved commissioning state: most routines turn the motor, so keep the driven load and your hands clear of it.
When does an asynchronous servo motor beat a permanent-magnet servo? #
Induction wins at high speed: there is no magnet to demagnetize and no magnet loss heating the rotor, so continuous high-speed running is easier on the motor, while a permanent-magnet servo still gives more torque per frame size at low and moderate speed.
The reason is thermal, not magnetic. Rotor loss in an induction machine equals slip times the power crossing the air gap — at the 4 percent slip of the worked example, 4 percent of air-gap power becomes rotor heat — and at low speed with high torque the slip fraction grows, exactly where a permanent-magnet rotor, carrying no rotor current, stays cool and dense with torque. Run the axis fast instead and the balance tips: no magnet temperature or demagnetization limit, no magnet loss adding heat at high electrical frequency, and field weakening above base speed costs the drive little more than torque headroom, where a permanent-magnet servo runs into the voltage ceiling of its own back-EMF sooner. Main-spindle and high-speed duties are the natural induction territory.
As a working decision: low-speed, high-torque, compact axes go permanent-magnet; sustained high-speed or hot, high-duty cycles favor the cage rotor, whose commodity construction also eases spare sourcing years down the line. The synchronous vs asynchronous servo motor comparison works through the full trade-off, including the drive-side consequences.
What tests prove the axis is set up correctly? #
Commission in this order and the axis proves itself in four checks: feedback direction at low speed, steady-state speed regulation, position tracking against the configured scaling, and a representative load cycle with current and temperature inside the motor's documented limits.
Run them in the same guarded commissioning condition the identification routine used.
- Feedback direction at low speed. Command a slow rotation — a few tens of rpm — and confirm the actual-value sign follows the command and the motion is smooth. Direction and count errors come from wiring and assignment, and on a resolver-equipped axis from mounting alignment: why resolver mounting angle faults an induction motor drive shows what a misaligned resolver does downstream.
- Speed regulation. Step the speed command and load the shaft: actual speed should settle on command within the application's tolerance, without oscillation or unexplained current limiting. Slip is internal — the shaft holds the command even as the field-to-rotor gap changes with load.
- Position tracking. Move to known positions and compare measured travel with the configured mechanical scaling; final position error must meet the machine's own acceptance criterion.
- Load cycle and temperature. Run the representative duty and watch current and motor temperature against the documented limits — the longest dwell at low speed is the case to watch, because shaft-driven cooling fades exactly there.
If all four pass within the documented limits, the induction motor is doing servo work, full stop. If speed holds but position drifts, the fault sits in feedback or scaling, not in the asynchronous construction — swapping the motor will not fix it.
Questions asked
Can an asynchronous servo motor run from an ordinary VFD?
Yes, for plain speed duty: a standard VFD in scalar or sensorless vector mode will spin it within the motor's ratings. What you give up is servo behavior: loose speed holding under load steps, no torque model, and no position control, because there is no shaft feedback in the loop. For a positioning axis, use a servo drive running vector control with the nameplate data and an encoder or resolver.
Why does an asynchronous servo motor run hot while holding zero speed?
The drive keeps magnetizing the motor even with the shaft stopped, so flux-producing current heats the windings with no mechanical output to show for it. A shaft-mounted cooling fan gives no airflow at standstill either, so the thermal margin shrinks during exactly the hardest duty. Stay within the motor's documented standstill and low-speed duty limits, and add forced cooling where the axis dwells at zero speed under load.
Does rising slip mean the motor is failing?
Not on its own. Slip rises whenever load rises, because that is how a cage rotor draws more torque. The warning signs are slip climbing without a matching load, speed sagging at a fixed command while torque current grows, or slip present at no load, which points to a drag or bind in the mechanics, wrong motor data in the drive, or a feedback fault. Judge slip against measured load, never against a fixed number.
What slip should a healthy asynchronous servo motor show at rated load?
Single-digit percentage slip at rated torque is a common rule of thumb for induction machines, but cage designs differ with their intended dynamics, so treat it as a starting guess only. Compute the value for your motor from its nameplate: synchronous speed from the pole count and rated frequency, rated speed from the plate, and the difference over synchronous speed. Where a datasheet figure exists for the exact motor, take that instead.