Selection guide
What holds a part on a moving nest: friction, clamp or vacuum
Short answer
A part stays on a moving nest only through an explicit retention method. Friction on a dry horizontal nest holds while acceleration stays under the slip limit, about 1.5 to 2 m/s² with a conservative steel-on-aluminium allowance; a faster transfer needs a located pocket, a spring or pneumatic clamp, or a vacuum cup, each sized from mass times acceleration with a safety factor of 2.

On this page
A part rides a nest only because something holds it there: geometry, a clamp or vacuum. Gravity pressing the part down gives you friction, and friction alone holds only while the axis stays below the slip limit, about 1.5 to 2 m/s² with a conservative dry steel-on-aluminium allowance. Most transfers from a robot placement to a robot pickup run faster than that, so you add retention sized from the part's mass times the acceleration, with a safety factor of 2. The slip-limit arithmetic, five retention methods compared, a worked sizing of a spring clamp and a vacuum cup, and the decision for each transfer follow.
The slip limit: friction alone holds only below μ·g #
On a horizontal nest the only force pressing the part down is its own weight, m·g, so the friction available is F = μ·m·g and the axis can accelerate the part only through that force. Sliding begins at a = μ·g, which is the whole physics of a loose part. Two things make the textbook coefficient a bad design number. Static friction drops once the part moves: published steel-on-steel data go from about 0.8 static to 0.4 sliding, roughly half, so a part that creeps keeps creeping. And measured dry values scatter: sliding tests on aluminium 6061 stabilise near 0.5 to 0.58, clean dry aluminium on mild steel reports about 0.45, and pure aluminium against steel about 0.72. Published dry values for this material pair therefore span roughly 0.45 to 0.72.
Design instead with an allowance of μ = 0.15 to 0.2, a rule of thumb deliberately below every published dry value, to cover oil film, dust, vibration and nest wear. That allowance puts the slip limit at μ·g = 1.5 to 2 m/s². The decision for a loose part: run it only when the profile's peak acceleration, including vibration and the jolt of the robot letting go, stays at or below 1.5 m/s². The acceleration is a profile choice fixed when the axis itself is sized; stroke, force and move time are covered in sizing a long-stroke linear actuator for a 500 N push.
Five retention methods compared #
| Method | What holds the part | Limit | Release for the pickup robot | Choose when |
|---|---|---|---|---|
| Located pocket | Walls block sliding: a positive stop, not a friction joint | Any acceleration the part and frame survive | The robot lifts the part straight out | The part has a stable datum and tolerates light wall contact |
| Flat pads, gravity | The part's weight through the friction coefficient | The slip cap on a clean, dry, horizontal nest | Nothing to release | Slow transfers that stay dry and level |
| Spring clamp | Stored spring force, through friction or against a lip | Sized from mass times acceleration | A lever or cam opens it, or the robot overcomes it | Retention must survive a power cut with no valve logic |
| Pneumatic clamp | Cylinder force pressing down or on an edge | The same friction sizing, with a safety factor | A valve retracts it on command before pickup | The cell has air and the release must be timed |
| Vacuum cup | Line vacuum pressing the part down; friction resists sliding | Cup area times vacuum level against twice the demand | Blow-off at the pickup pose | The top face must stay clear and the surface seals |
The pocket is the odd one out: it is a positive stop, so the question is not whether the part slides but what happens at each wall contact on a direction change. Check the part's tolerance to that light impact instead of friction.
Worked example: 0.8 kg part on a 3 m/s² transfer #
Everything below is a calculated example for these inputs, not a measured result. A 0.8 kg steel insert sits on a machined aluminium nest; the actuator moves it 0.6 m on a trapezoidal profile that peaks at 3.0 m/s².
Friction capacity, at the optimistic end of the allowance, μ = 0.2: F = μ·m·g = 0.2 × 0.8 kg × 9.81 m/s² = 1.57 N. Demand at peak acceleration: F = m·a = 0.8 kg × 3.0 m/s² = 2.4 N. The loose nest delivers 1.57 N against a 2.4 N demand, about 0.65 of it, so the part slides. If the takt allows a profile capped at the slip limit, slow down and keep the loose nest; otherwise hold the part.
Spring clamp, through the same friction, sized at twice the demand: μ·(N + m·g) ≥ 2·m·a gives 0.2 × (N + 7.85 N) ≥ 4.8 N, so N ≥ 16.2 N. A spring clamp pressing with about 16 N of normal force, the weight of a 1.6 kg mass, holds this transfer. If the clamp bears on a lip, step or hole of the part instead, it becomes a positive stop and the spring only has to keep the part seated.
Vacuum cup, same demand through friction, at an example working vacuum of 60 kPa below atmosphere, with a single cup of 25 mm bore: A = π·d²/4 = π × (0.025 m)² ÷ 4 = 4.91 × 10⁻⁴ m², and F = Δp·A = 60,000 Pa × 4.91 × 10⁻⁴ m² = 29.5 N. Pressing down with 29.5 N, the friction available is 0.2 × (29.5 N + 7.85 N) = 7.5 N, comfortably above the 4.8 N demand. The smallest cup that passes needs the same 16.2 N of normal force: A ≥ 16.2 N ÷ 60 kPa = 2.7 × 10⁻⁴ m², so d ≈ 19 mm. The 25 mm cup gives real margin without swamping the part.
Clamps: stored force versus commanded force #
A spring clamp holds with stored mechanical energy, so the retention survives a power cut with no valve logic at all. Size it by the friction rule above when it presses a flat face; the better geometry is a clamp that bears on a lip, step or hole, because then the spring only keeps the part seated against the locator, and you pick the spring from the seating force plus the effort of opening the lever at pickup. When the clamp's spring itself needs controlled compression or a powered open, the actuator choice is the one covered in choosing an actuator to compress a small spring precisely.
A pneumatic clamp follows the same friction sizing, with the normal force from the cylinder: bore area times the pressure the clamp actually sees while the axis runs, minus its return spring. One safety note: a clamp whose job is to keep the part from being thrown when the axis faults must stay closed when air or power disappear. That is the held-load principle ISO 10218-1 places on robot end effectors, and the machine's risk assessment under ISO 12100 decides whether the nest carries the same expectation. Meet it with a pilot-operated check valve on the clamp port or a spring-applied cylinder; the valve logic is the same one that keeps a gripper closed on its part, covered in pneumatic valve setup for double-acting robot grippers.
Vacuum cups: area times vacuum level #
A vacuum cup holds with F = Δp·A, where Δp is the vacuum level the generator actually maintains while the cup is sealed, not its best-case peak, and A is the cup's effective bore area. The worked example above sized one small cup; keep cups small and close to the part's centre of friction so the pickup gripper still reaches the part. Rules of thumb: safety factor 2 on a clean, dense, flat surface, and 3 to 4 on porous, rough, curved or oily surfaces. Fit a non-return valve at each cup so a stopped ejector or a torn line does not drop the part mid-move, and give the pickup a blow-off for a fast, clean release. If the nest is tilted or vertical, stop sizing through friction: the cup then carries m·(g + a) directly and the weight term adds instead of helping.
The decision for each transfer #
- Peak acceleration at or below 1.5 m/s², horizontal nest, dry station: located pocket or flat pads with friction only, nothing to release and nothing to fail. Slow the profile to fit the cap before adding hardware; the takt decides whether that is acceptable.
- Above the cap, or oil, vibration or impacts at the station: clamp the part. Spring clamp when the release can be mechanical; pneumatic clamp with a check valve or spring-applied cylinder when release must be timed. Both are sized at twice the m·a demand through the friction rule; the example needed about 16 N of normal force.
- Top face must stay clear for the pickup, or clamp marks are unacceptable: vacuum, cup bore from the same arithmetic with a safety factor of 2 on a good sealing surface, and a non-return valve at every cup.
- High jerk, hard stops, or a part that must not shift at all between placement and pickup: closed pocket as a positive stop; the robot lifts the part out.
Questions asked
Does coolant or oil on the nest change the friction-only limit?
Badly. Published dry coefficients already scatter by a factor of about three, and a lubricated steel-on-steel couple slides at roughly half its dry value, so an oily or wet nest can halve the friction-only cap or worse. If the station cannot stay clean and dry, treat friction as zero: hold the part with a pocket, a clamp or a vacuum cup and do not count the nest surface as retention.
What if the 6-axis robot needs the part's top face clear for pickup?
Move retention off the top. An edge clamp or a side-acting pin can bear on a face the gripper never touches, or the part can drop into a closed pocket that acts as a positive stop with nothing above it. A vacuum cup is then ruled out unless the gripper jaws clear the cup stem, so check the gripper's approach envelope against the cup layout before committing to vacuum.
How do I prove the retention before the cell runs production?
Mark a witness line across part and nest, stroke the axis at the real motion profile, then at roughly 20% above its peak acceleration, for 50 cycles, and re-check the line. Any shift means the holding method is marginal, not proven. Re-run the test after the nest wears, when a new part batch arrives with a different surface finish, or when coolant reaches the station.
Does a locating pocket count as retention at any acceleration?
Yes. A closed pocket is a positive stop, so acceleration no longer decides whether the part slides; the part only rattles within the pocket clearance and loads the wall on each direction change. Size that clearance from the pose error the pickup robot tolerates, confirm the part survives repeated wall contact, and let the nest, not friction, own the location.