AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Selection guide

Why 12 tapping spindle reversing cycles per minute decide servo size

Servo and stepper motion Published 8 min read By AutomateDirectUSA engineering team

Short answer

Yes, an AC servo suits this tapping spindle. At 12 reversing cycles a minute the motor is sized by the repeated torque cycle: time-weighted RMS torque against the derated continuous rating, and peak ramp torque against the drive's limit. With the lead screw positively driving the tap lead, the Z axis needs no electronic synchronization, only verified lead and backlash.

On this page
  1. What the cycle rate fixes first
  2. Feed: a driven lead screw removes the Z synchronization problem
  3. Sizing: RMS torque for the heat, peak torque for the ramps
  4. Worked example: RMS torque for the 1 11/16-12 tap at a 5 s cycle
  5. Reversing duty: what actually takes the wear
  6. What to specify, and where each number comes from
  7. Commissioning at rate
  8. Questions asked

Yes, an AC servo is the right drive for this tapping spindle, and the reversing rate, not the 1 11/16-12 thread, is what decides its size. Cutting torque in the zinc casting sets the middle of the cycle, but at 12 reversing cycles a minute the motor lives inside a repeated accelerate, cut, stop, reverse, spin-out cycle, so continuous size comes from time-weighted RMS torque while the ramps set the peak-torque and braking checks. Feed is the second decision: because a lead screw unit drives the tap lead mechanically, the Z axis needs no electronic synchronization, only a verified lead, ratio and low backlash. The selection steps, a worked RMS calculation for this machine, and the commissioning checks that confirm them follow.

What the cycle rate fixes first #

With 12 complete forward-and-reverse cycles a minute, one cycle lasts 60 ÷ 12 = 5.0 s, and everything in it, accelerate, cut in, stop, reverse, spin out, stop, index, must fit inside that time. Run continuously, the spindle completes 720 cycles an hour and the drive sees 24 direction changes a minute.

Pin one definition down with the machine builder: whether the stated rate counts complete cycles or single direction changes. This article takes it as complete cycles, which gives the 5.0 s cycle used in the worked example. If it means direction changes, the cycle stretches to 10 s, every torque segment can stretch with it, and the selection gets easier, so the complete-cycle reading is the conservative one to size against.

The count is not itself the wear problem. A brushless servo has no brushes or commutator that care about direction, but at this rate the motor never settles into a steady cutting state, so its heating is decided by the whole cycle profile, not by the cutting point alone.

Feed: a driven lead screw removes the Z synchronization problem #

The tap is advanced by a lead screw unit, and that architecture is sound: with the screw driven positively from the spindle through gears or belts, with nothing in the path that can slip or disengage under load, axial travel per spindle revolution is fixed mechanically. If the spindle sags a little in speed when the tap engages, the feed sags with it and the pitch survives. That is the property rigid mechanical tapping feeds have always relied on, and it is why this machine does not need an electronically synchronized Z axis.

Three things must be verified before trusting it:

  • Tap lead. The -12 in 1 11/16-12 means 12 threads per inch, so a single-start tap advances 1/12 in, 0.083 in or about 2.12 mm, per revolution. Confirm on the drawing that the tap is single-start.
  • Screw travel and ratio. Lead screw travel per revolution times the spindle-to-screw drive ratio must equal the tap lead, or the tap fights the screw on every tooth and one of them wins.
  • Backlash and wind-up. Measure lost motion at the tap with the screw turned by hand and an indicator on the spindle nose; lost motion here becomes pitch error exactly where the thread matters, at the bottom of the hole and through the reversal.

If the unit contains a friction clutch or any element that can slip during the cut, the mechanical guarantee is gone and the Z axis becomes its own servo synchronized to an encoder on the final spindle, because the motor's rear encoder cannot see motion lost between motor and spindle. That electronically coordinated arrangement is covered in servo drive selection for rigid tapping spindle and feed axes.

Sizing: RMS torque for the heat, peak torque for the ramps #

Two limits govern a reversing spindle, and they are checked separately.

Thermal limit. Compute the time-weighted root-mean-square (RMS) torque over one full cycle: square the torque of each segment, weight it by the segment's duration, average over the cycle time, take the square root. That is the steady torque which would heat the motor exactly like the real repeating cycle. Compare it against the motor's continuous rating after derating for mounting: servo makers state continuous torque for a specified heatsink plate, commonly an aluminium plate of stated thickness, and a motor on a thin adapter bracket runs derated per its installation manual. On reversing duty, size against the derated number, never the headline number.

Peak limit. The four ramps per cycle demand peak torque briefly, and the drive must deliver the current for them. Ramp torque comes from the total rotating inertia and the commanded acceleration, and calculating servo axis acceleration for torque sizing shows that step; the current it draws is in how to calculate servo motor current from required torque. Keep the peak inside both the motor's overload rating and the drive's peak current. A motor that passes peak but misses continuous will cut cleanly for ten minutes and then fault hot at production rate; preventing exactly that failure is what the RMS number is for.

Worked example: RMS torque for the 1 11/16-12 tap at a 5 s cycle #

Inputs #

From the application: 12 complete reversing cycles a minute, so the cycle time is 60 ÷ 12 = 5.0 s; tap lead 1/12 in per revolution (single-start, derived above); zinc casting; the spindle currently runs on a hydraulic motor.

Example values for the rest, to be replaced by measurements from the machine: spindle speed 300 rpm; tapped depth 0.75 in; cutting torque 30 lb·in measured at the spindle; retraction torque 10 lb·in (friction only); ramp torque 60 lb·in on each of the four accel and decel ramps; ramp time 0.2 s.

The segment times follow from these: feed rate is 300 rpm × 1/12 in per revolution = 25 in/min, or 0.42 in/s, so cutting 0.75 in deep takes 0.75 ÷ 0.42 = 1.8 s, and spinning out takes the same 1.8 s. Four ramps at 0.2 s take 0.8 s. Dwell and index take the remainder: 5.0 − 1.8 − 1.8 − 0.8 = 0.6 s.

The rule #

Time-weighted RMS torque: square each segment's torque, multiply by its duration, sum over the cycle, divide by the cycle time, take the square root.

The arithmetic #

Segment Time (s) Torque (lb·in) Torque squared × time (lb·in²·s)
Accelerate to tapping speed 0.2 60 720
Cut in 1.8 30 1,620
Decelerate and stop 0.2 60 720
Accelerate in reverse 0.2 60 720
Spin out 1.8 10 180
Decelerate to stop 0.2 60 720
Dwell, index to next part 0.6 0 0
Whole cycle 5.0 4,680

RMS torque = square root of (4,680 ÷ 5.0) = square root of 936 = 30.6 lb·in, about 3.5 N·m. Peak torque is the ramp value, about 6.8 N·m, held 0.2 s at a time, short against the overload window servos publish, which is normally seconds.

Result and decision #

The selection threshold for this example: the motor's derated continuous torque must be at or above 30.6 lb·in, and its overload rating at or above the ramp peak, with the drive's peak current sized for that same peak. Below the RMS figure the motor overheats at this rate no matter how much peak torque it has, and the fix is the next frame size or a better heatsink path, not a bigger drive. If the derated continuous rating only just reaches the RMS value, move up one frame anyway: reversing duty leaves no margin for a dull tap.

Reversing duty: what actually takes the wear #

The direction changes themselves do not wear out a brushless AC servo: no brushes, no commutator, and the bearings do not count reversals. That answers the reliability question behind replacing the hydraulic motor: sized as above, the servo is the durable element of the drive train. The cycle count lands on four other parts:

  • The drive's braking path. Every stop returns the spindle's kinetic energy to the DC bus. Give the drive's energy or sizing routine the total rotating inertia and the run speed; it returns the energy per stop, and the braking resistor or regenerative unit must absorb it at the cycle rate.
  • The coupling and its keyway, which see full torque reversal every cycle. Use a torsionally stiff, backlash-free type, bellows or beam, rather than a jaw coupling with insert clearance.
  • The lead screw unit's backlash, hammered twice per cycle. Pitch drift on a gauged thread after weeks of production points here first.
  • The tap. It sees every cycle too; the drive's torque limit is what keeps a dull tap from becoming a broken one, and proving that limit is a commissioning step below.

What to specify, and where each number comes from #

Quantity What it decides Where it comes from
Cycle rate, defined as complete cycles or direction changes Cycle time: the RMS denominator and the reversal frequency The machine builder's sequence
Cutting torque at the spindle The cut segment of the torque profile Measured directly at the spindle during a real cut; direct measurement is more dependable than inference from motor current
Retraction torque The spin-out segment The same measurement
Ramp torque and ramp time Peak motor torque and drive peak current Total rotating inertia and commanded acceleration
Time-weighted RMS torque Continuous torque after mounting derating Calculated from the profile, as in the worked example
Kinetic energy per stop Braking resistor or regenerative sizing The drive's energy routine, fed with inertia and run speed
Tap lead against screw travel and drive ratio Whether the mechanics hold pitch without an electronic Z axis The tap drawing, plus screw travel measured per revolution
Backlash at the tap Thread pitch quality through the reversal Measured with an indicator at the spindle nose

Commissioning at rate #

  • Run a full half hour at cycle rate and watch the motor temperature the drive reports: it must level off. A temperature still climbing means the real profile beats the estimate and the continuous margin is gone.
  • Watch DC bus voltage through a reversal: a rise toward the overvoltage trip level means the braking path is undersized.
  • Prove the torque limit with a deliberate stall, guard in place and fixture empty: the drive should stop cleanly on its torque or current limit, not on a hardware fault.
  • Gauge the thread after the first hundred cycles and again at the end of the first shift. Pitch that drifts with cycle count points at backlash in the screw drive, not at the servo.

Questions asked

How many reversals will the spindle see in a year?

At the machine's rate, one 8-hour shift holds 5,760 complete cycles and a 250-shift year about 1.44 million. The servo does not count these: a brushless motor has no brushes or commutator to wear out, so the count lands on the coupling, the lead screw's backlash, the tap and the braking resistor's duty rating. Specify those parts for the count; the motor only needs its RMS and peak limits held.

Can the old hydraulic motor's specifications size the servo?

Not on their own. Hydraulic pressure and displacement give an average torque, not a cycle profile, and the circuit's relief valve may have capped the real cutting load for years. Record torque directly at the spindle during a production cycle with a torque transducer; deriving it from motor current is the weaker method. The same recording supplies the cutting, retraction and ramp figures the RMS calculation needs.

Where should the drive's torque limit be set?

Start at about 150 percent of the measured cutting torque, 45 lb·in for the example profile, and treat that as a rule of thumb to tune, not a fixed figure. That setting lets the tap cut freely while a dull or jammed tap stalls the drive before it wrecks the tap, the workpiece or the lead screw unit. Confirm during commissioning with a deliberate stall: the drive should stop cleanly on its torque limit, with no hardware overcurrent trip.

Will the reversals overload the drive's braking resistor?

Average braking power equals the kinetic energy returned at each stop multiplied by stops per second; this machine stops twice per cycle, so the bus sees reversal energy 24 times a minute. Feed the drive's energy routine the real spindle inertia and run speed, multiply the energy per stop it reports by 0.4 stops per second, and keep the result below the built-in resistor's continuous rating. Above it, add the external resistor or regenerative unit the drive supports rather than stretching ramp times.

Keep reading

  • Selection guide

    Servo drive selection for rigid tapping spindle and feed axes

    Select the tapping drive pair by whether the interface keeps feed position locked to the spindle's actual angle, not by which protocol is easier to wire. At the spindle's rated 2000 rpm the feed must run 2000 times the thread lead in millimetres per minute, and the 5 Nm spindle rating works out to about 1.05 kW of shaft power. Two independent pulse-train axes need a tension-compensating tap holder or a controller that gears feed to measured spindle angle.

    Servo and stepper motion

  • Comparison

    Servo or Stepper for Fast Start-Stop Feed Rollers

    At 28 in feeds and 100 bags/min, a 2 in roller peaks near 1,337 RPM with about 1,400 rad/s² of angular acceleration; through the 5:3 belt drive the motor sees about 2,230 RPM. That is deep in the torque cliff where a hybrid stepper keeps only a fraction of its low-speed torque and loses steps silently, so this machine takes a servo.

    Servo and stepper motion

  • Explainer

    Can a servo spindle retrofit replace a DC lathe spindle?

    Yes, an 11 kW servo motor and drive can replace a DC lathe spindle, but the kilowatt rating decides nothing by itself. The retrofit works when the servo drive accepts step-and-direction speed commands, the controller's spindle output matches that interface electrically, and the motor's continuous torque covers the lathe's worst cut through the belt reduction. Bench-test enable, direction and speed response with the motor uncoupled before it turns a chuck.

    Servo and stepper motion