Explainer
Why Two Linear Actuators Must Extend Opposite to Angle a Blade
Short answer
Two-wire actuators need a dual reversing controller with the motor leads on one channel swapped, so one command extends one rod and retracts the other; feedback actuators need a two-channel position controller commanding mirrored targets. A second speed controller alone creates no opposed motion, and an open-loop pair drifts apart and jams.

On this page
Angling a blade with two linear actuators means one rod extends while the other retracts, and the opposite command swaps them. The electrical answer is two reversing outputs driven from one command, with the motor leads on one channel swapped so a single command produces opposed travel; actuators that report position add a two-channel controller steering both rods to mirrored targets. A second speed controller with no mix does neither, and the mechanics decide the rest: mount the pair parallel at the blade's straight position and give the lagging rod somewhere to yield, or an open-loop pair drifts apart and jams.
The pair is a push-pull mechanism #
A blade on a central pivot needs rotation, and two actuators deliver it by exchange: whatever length one rod gives up, the other takes on. The pair behaves like opposed arms on two racks and one pinion, converting opposed linear travel into rotation about a fixed center. The same geometry angles diverter flaps and deflectors on production machines, so the reasoning carries over from a model plow.
Geometry sets the terms. At the blade's straight position, mount both actuators parallel to each other and mirrored about the pivot, so one millimetre retracted on the left is matched by one millimetre extended on the right and the blade rotates instead of wracking. If the mounting distances differ, equal rod travel produces unequal angles each side. Set neutral with both rods near mid-stroke so the stroke is available in both directions.
The rod ends matter as much as the mounts: any play there becomes blade slop at neutral, and where linear actuator ball joint play comes from breaks down which joint is responsible.
Identify the actuator before choosing the electronics #
Nothing about the housing tells you how an actuator is controlled; the label and datasheet do. Write down four things per unit: supply voltage, running and stall current, whether internal limit switches stop the rod at each end, and whether a position signal comes out.
Two kinds cover most of what you will meet. A two-wire actuator is a brushed DC motor with a gear train and internal end limits; its direction follows motor polarity and it reports nothing. A feedback actuator adds a potentiometer or Hall sensor and either accepts a position command or exposes that signal on a third wire.
A receiver channel or servo mixer outputs a command signal, not motor power. Never wire a motor to a signal pin; the command must pass through a driver stage sized for the motor.
The controller for a two-wire pair #
What the pair needs electrically is one reversing output per actuator. A dual H-bridge controller does this: each bridge flips the polarity of its own motor, and both channels take the same command source. Swap the two motor leads on one channel and the same command extends one rod while it retracts the other.
For switch or PLC control, the same function is relay logic: each actuator gets a polarity-reversing stage, classically a DPDT arrangement, with the two stages energized in opposite patterns. Rate the driver for the actuator's stall current, not its running current, because a jammed blade puts the motor at stall.
The controller for a feedback pair #
With position signals available, the controller closes the loop on both channels. Calibrate each actuator first: drive it to each end, its limit switches protecting the move, and record the signal value at both positions. Then map one blade-angle command to two opposed targets, mirrored about the straight position. A command for left sends one channel toward its extended target and the other toward its retracted target; right swaps them.
Feedback wiring alone synchronizes nothing. The controller has to compare each rod against its own target and correct while moving, exactly the discipline described for synchronizing two servo axes on one heavy lift.
Why an open-loop pair drifts and jams #
Two identical actuators do not run at identical speed once loads differ. Worked example, calculated from assumed inputs rather than measured: each actuator strokes 100 mm; the left unit runs at 12 mm/s, the right at 11 mm/s because it carries more of the pivot friction. Command full travel and the left rod finishes in 100 mm ÷ 12 mm/s = 8.3 s. In that time the right rod covers 11 mm/s × 8.3 s ≈ 92 mm, so when the left motor hits its internal limit the right one is still 8.3 mm short and keeps pushing.
With a rigid linkage that shortfall has nowhere to go: the left end stop and the right motor fight over it until something flexes, a mount stretches, or a motor stalls. On the return command the error repeats in the other direction, and cycle by cycle the pair's alignment degrades until the blade jams at an angle.
Parallel mounting at neutral keeps the geometry honest but does nothing to speed drift. Open-loop is acceptable when the linkage can absorb the mismatch (a slotted pin, a compliant rod end, flex in the mounts) and each actuator ends travel on its own limit switch. Hard-bolt both rods to a stiff blade with no give and open-loop will jam; that case needs the feedback pair.
Bring it up in stages #
- Block the blade so it cannot drop and disconnect actuator power; a raised blade is stored energy, handled under your machine's risk assessment, the ISO 12100 discipline of identifying hazards and reducing them by design first.
- With both rod ends disconnected, jog each actuator with short taps and mark which command extends each rod.
- If both rods extend on the same command, swap the motor leads on one channel; on a feedback actuator, reverse the direction in its calibration instead.
- Reconnect the rods with the blade at straight and both rods near mid-stroke; the pins should drop in without persuasion. Forcing a pin means the geometry is wrong, not the wiring.
- Run short commands and watch both rods. Stop the moment the rods fight each other, one reaches a limit early, or a mount flexes.
- Cycle left, right and back to neutral several times; the blade should settle on the same straight mark from both directions. A neutral that walks is open-loop drift announcing itself.
Reading the symptoms #
| What you see | Most likely cause | Confirming check |
|---|---|---|
| Both rods extend on one command | One channel not reversed | Swap that channel's motor leads, retest |
| Blade angles, then stalls | One rod at its limit while the other drives | Mark each rod at full angle; one mark sits at the stop first |
| Neutral walks off the mark over cycles | Open-loop speed drift | Compare left-approach and right-approach neutral marks |
| One rod dead | Power path, connector, or its internal limit | Measure voltage at that motor's leads during a command |
One actuator can do the job alone #
Before committing to the pair, check whether you need it. A single actuator whose rod works both in push and in pull angles the blade both ways, provided the mount keeps the rod load near axial through the arc and the rod is stiff enough in compression at full extension. If one actuator sized for the full angling force fits behind the blade, use it: a lone rod has no partner to drift against, and the whole synchronization problem disappears. Choose the pair when you want symmetric stiffness at both angle extremes, or when one unit cannot deliver the force in both directions through your mounting geometry.
The decision #
Two-wire actuators with a linkage that has give, or rods that finish on their own limit switches: dual reversing controller, one H-bridge per actuator (or DPDT relay stages for switch and PLC control), rated for stall current, with the motor leads on one channel swapped. This is the cheap, robust answer for the model plow.
Two-wire actuators rigidly bolted with no give anywhere: do not run them open-loop. Add compliance at one rod end or move to feedback actuators.
Feedback actuators: two-channel position controller, both channels calibrated end to end, one command mapped to mirrored targets, pair mounted parallel at the straight position with neutral near mid-stroke.
Any case: prove the direction of each rod with the linkage disconnected before the blade goes back on, and treat a walking neutral or a stall near full angle as a direction, compliance or feedback problem, never a reason for more current.
Questions asked
Can both actuators share one output channel?
No. One reversing output feeds both motors the same polarity, so both rods extend together and the opposed motion is gone before anything jams. The bridge would also have to survive the stall current of two motors at once. Give each actuator its own reversing channel and swap the leads on one of them; shared wiring only suits mechanics that want both rods travelling the same way.
What happens if I swap the motor wires on an actuator that has position feedback?
The position signal keeps its original orientation, so the controller now sees movement opposite to its command and drives the rod hard into an end limit. Reverse the direction inside the controller's calibration instead. If the leads must be swapped for wiring reasons, recalibrate both endpoints before the first powered move.
Do mechanical end stops remove the need for position feedback?
No. Stops end travel; they do nothing about speed mismatch in the middle of the stroke, and a lagging rod pushes into its stop while its partner keeps driving. Accept open-loop only when the linkage can absorb that mismatch and each actuator finishes on its own internal limit switch. Otherwise close the loop on position.
Will a more powerful controller stop the stalling near full angle?
No. The stall is two rods disputing a few millimetres of travel, and more current only bends something more expensive. The real fixes are a corrected direction reversal, compliance in the linkage, or opposed position targets under feedback. Establish which rod stops first before touching the electronics.
Can a servo mixer drive the actuators directly?