A servo motor that vibrates and heats rapidly is usually producing excessive current at or near standstill, dragging mechanically, or running with wrong motor data or corrupted feedback. Read the drive's fault list first, then measure holding current at a zero-speed command, then test at low speed. A replacement with the same base part number but no option suffix is not a like-for-like swap until every option code is compared.

On this page
  1. Read the drive before touching the machine
  2. Current at a zero-speed command
  3. The low-speed test and mechanical drag
  4. Motor data and feedback integrity
  5. Replacing the motor: the option suffix decides
  6. The decision for each case
  7. Questions asked

A servo motor that vibrates audibly and heats within minutes is almost always producing more current than the work requires, or fighting something mechanical. On a machine with a motor like the Siemens 1FK7034-2AK71-1RG2-Z, four causes cover nearly every case, and they are cheapest to check in this order: a fault the drive has already logged, excessive or oscillating current at a zero-speed command, mechanical drag from a brake, coupling or bearing, and wrong motor data or corrupted feedback in the drive. Stop running the axis in production and split the fault before you touch a tuning parameter or order a replacement. If the vibration is the only symptom and the motor stays cool, start instead with the mechanics-versus-tuning sequence in servo motor noise: mechanics or tuning first.

Read the drive before touching the machine #

The drive has been watching the motor the whole time. Before clearing anything, record:

  • Active faults and the fault history, with timestamps. A temperature-model fault, a feedback fault or an overcurrent trip already tells you which branch below to take.
  • The configured motor data: which motor the drive believes it is driving, and whether that selection includes the installed options.
  • Any temperature indication the drive reports from the motor's sensor, if one is wired.

Work each recorded fault through the installed drive's documentation before any motion test. A drive that faults on its thermal model while the housing is still cool is protecting a winding you cannot see; do not reset and rerun to "see if it holds".

Current at a zero-speed command #

This is the single most useful measurement, because a stationary shaft is not an unloaded motor. Holding current produces full torque at zero speed, and all of it becomes heat in the winding. Copper loss rises with the square of current:

P = 3 × I² × R

where I is the phase current in amps rms and R is the phase resistance in ohms from the datasheet of the exact motor. Worked example with illustrative inputs, not a catalog rating: R = 0.25 Ω per phase, holding current 4 A rms gives P = 3 × (4 A)² × 0.25 Ω = 12 W in the winding. If an oscillation drives the current to 6 A rms, P = 3 × (6 A)² × 0.25 Ω = 27 W, which is 27/12 = 2.25 times the heat of the steady case. That arithmetic is why a small-sounding vibration can heat a motor fast: the loss scales with current squared, so a 50 percent current rise more than doubles the heating.

Command zero speed with the axis enabled and safe, then trend torque or current and actual speed:

  • Steady elevated current with a gravity-loaded or preloaded axis is legitimate holding work; check whether the machine really needs that much, and see the standstill analysis in why a servo motor overheats at standstill on a rack axis.
  • Current oscillating at a fixed frequency with no physical shaft motion is a control or feedback problem. Go to the motor-data and feedback checks below before touching the mechanics.
  • Clean, low current at zero speed means the heat is generated only in motion; continue to the low-speed test.

The low-speed test and mechanical drag #

Run the axis at a slow commanded speed, watching current, actual speed and where the sound comes from. A disturbance that repeats once per shaft revolution points at rotating hardware: coupling, brake, bearing. A disturbance that follows the motion command rather than shaft position points back at control settings.

Then isolate the energy and inspect, in this order:

  • The brake, if fitted. A brake that is not fully released drags continuously, and low speed does not protect it. Compare the brake supply voltage and the release sequence against the motor and machine documentation; the brake must release before commanded motion. If the brake behavior is unclear, what a servo motor holding brake does and does not do sets the expectations. Local heating concentrated at the brake end of the motor is the confirming sign of drag.
  • Coupling and alignment. Check for angular or parallel misalignment, shaft contact, loose clamping and belt tension where a belt is in the train. Misalignment loads the motor bearings and shows up as once-per-revolution current ripple.
  • Bearings and guides. Spin the mechanism by hand where the design allows and feel for binding or roughness; a bearing that runs rough at hand speed will not survive servo duty.

Uncouple the motor from the load only where the machine permits, after securing any gravity load that the coupling was holding. If vibration and current fall substantially when uncoupled, the fault is in the driven mechanism and the motor is a victim. If they persist unloaded, continue to motor data and feedback.

Motor data and feedback integrity #

The drive computes torque from configured motor characteristics and measured position. Two failures live here:

  • Wrong motor data. The selection or entered data in the drive must correspond to the complete installed motor, options included. Incorrect data impairs current control and can drive the axis into oscillation that looks mechanical. Correct a mismatch only through the drive's documented commissioning process, not by editing individual values.
  • Corrupted feedback. With the shaft at rest and held by the normal control, trend actual position and speed: there should be no unexplained jumps. Apparent feedback motion that the shaft is not physically making is electrical noise or a failing encoder, not real oscillation. With energy isolated, check connector seating, pin condition, cable damage, shielding and routing near drive power cables. If an encoder has already been replaced, the identification procedure in commissioning a replacement servo encoder with motor ID data is the one to follow; a feedback conflict can also mimic the no-commutation symptom covered in why an AC servo hums and thermally trips before any jog.

Replacing the motor: the option suffix decides #

The question of swapping a 1FK7034-2AK71-1RG2-Z for a 1FK7034-2AK71-1RG2 is answered by one rule: the complete designation must match, and the -Z suffix is part of the designation. That suffix marks additional order-specific options; the option codes themselves are listed in the order documentation and in the manufacturer's support entry for the exact order number. Matching the base characters alone does not establish equivalence. Compare code by code:

Item to compare What must match or be documented What a mismatch causes
Full designation and option codes Every character, including the suffix options An omitted option changes installation requirements silently
Feedback system Encoder type, resolution, connections, drive compatibility No operation, or unstable control from misinterpreted feedback
Mechanical interface Shaft, flange, coupling fit, permitted radial and axial loads Vibration and bearing loads from a forced fit
Brake and temperature sensor Fitted equipment, supply, monitoring connections Brake drag or missing winding protection
Electrical data Nameplate voltage, current, speed, torque Drive commands unsuitable current or torque

If every line matches, the swap is mechanical plus one commissioning step: confirm the drive's motor data still corresponds to that complete designation before enabling. If any line differs, resolve the option through the manufacturer or an authorized distributor before energizing; the replacement is not approved until then. And note the order of operations: replacing the motor before the current-at-zero-speed and low-speed checks risks installing a good motor into the same dragging brake or misaligned coupling, where it will heat exactly the same way.

The decision for each case #

  • A fault is already logged: fix what that fault means first; do not clear and rerun.
  • Current oscillates at a zero-speed command with no physical motion: feedback or motor data. Check cable, connector and configured motor data; do not touch mechanics or gains.
  • Current is steady and high at standstill: real holding work or brake drag. Verify brake release, then the mechanical chain.
  • Vibration repeats with shaft rotation at low speed: rotating hardware. Inspect brake, coupling alignment and bearings; uncouple to confirm.
  • Vibration persists uncoupled: the motor itself or its feedback; check winding temperature sensing and encoder before condemning the motor.
  • Replacement: same base number without the -Z suffix is a swap only after every option code is confirmed equal; otherwise it is a re-engineering job, not a spare.

Questions asked

How hot is too hot for a servo motor winding?

The limit is the thermal class printed on the nameplate, defined in IEC 60085: Class F allows a winding hotspot of 155 degrees Celsius and Class H allows 180 degrees Celsius. The housing you touch runs well below the winding temperature, so a housing reading cannot confirm the winding is safe. If the motor has an embedded temperature sensor wired to the drive, trend that value; it is the number that counts.

Does the current shown on the drive compare directly with the rated current on the nameplate?

Not always. Drives display current on different bases: some show the instantaneous peak value, others an rms-equivalent torque-producing value. Compare the displayed value only against a rating expressed on the same basis, or you will reject a healthy motor or accept an overloaded one. Check the drive documentation for what its current display represents before drawing a conclusion from the number.

Where do I find what the option suffix on my motor's order number contains?

The installed options are listed as order codes in the original order documentation for that exact order number, and the manufacturer's support entry for the full designation shows the same option codes. Read the complete nameplate first: the suffix only points to the list, it does not describe the options itself. Compare that list, code by code, with the proposed replacement before approving the swap.

Can I stop the vibration by lowering the servo gains?

Lowering the gains usually hides the symptom and keeps the heat. If the vibration comes from mechanical drag or a dragging brake, the torque demand is unchanged, so the copper losses and the heating stay. If it comes from corrupted feedback, softer gains let the axis wander instead of oscillate, which is worse for positioning. Clean up the current at a zero-speed command first; tune only after that trace is flat.

Keep reading

  • Troubleshooting

    Why a servo motor overheats at standstill on a rack axis

    A servo that stays enabled after a stop keeps its position loop closed, so rack binding, an over-compressed engagement spring, an unbalanced load or slack-driven hunting keeps torque current flowing at zero speed until the winding fails. Measure the standstill current, uncouple the pinion to split mechanical from electrical causes, then set the drive's continuous limit to the motor's rated current and repair whatever kept the current high.

    Servo and stepper motion

  • Selection guide

    Matching a servo drive to a motor: four checks before you buy

    A servo drive fits a motor when four checks pass: supply and bus voltage against the motor's back-EMF and insulation, continuous and peak output current against the nameplate values converted to one basis, the drive's feedback input against the exact encoder type, and the command interface against your controller. Work through them in order, then get a written sizing confirmation from the drive maker before you order.

    Servo and stepper motion

  • Troubleshooting

    Why a vertical servo axis drops on E-stop or power off

    A vertical servo axis that drops on E-stop or control-off has no passive holding force: the motor holds only while the drive supplies torque, and no parameter changes that. The fix is a working spring-applied holding brake, a counterbalance or a self-locking mechanism. Block the axis, confirm the brake option from the motor order number, then measure the brake coil voltage in every machine state.

    Servo and stepper motion