AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Selection guide

Which actuator suits a 270 degree robot joint

Motors, gearboxes and drives sizing Published 10 min read By AutomateDirectUSA engineering team

Short answer

Size a 270 degree robot joint from measured peak and holding torque, speed and commanded travel at the output shaft, never from the 1-2 A the robot draws. A positional servo rated above those values with 270 degrees of commanded travel, or a geared brushed DC motor with an H-bridge rated above the motor's stall current, are both valid answers; a worked forearm example needs 1.1 N·m peak and 0.8 N·m continuous.

On this page
  1. Why can't the 1-2 A reading size the actuator?
  2. What must the joint deliver before you choose?
  3. How do the numbers work out for a forearm joint?
  4. Does a positional servo cover a 270 degree joint?
  5. Does brushed DC with an H-bridge and a PID loop work?
  6. What does the H-bridge have to survive?
  7. How many poles should the motor have?
  8. How do you prove the axis before it runs free?
  9. Questions asked

A 270 degree robot joint has two answers that both work: an integrated positional servo whose commanded travel covers the full 270 degrees and whose rated torque covers the measured joint load, or a brushed DC motor behind a gearbox, driven by an H-bridge from the microcontroller's PWM output, with an optical encoder feeding a PID position loop. Choose between them on four measured quantities at the output shaft — peak torque, holding torque, speed and commanded travel — never on the 1-2 A the robot happens to draw. The worked example below needs 1.1 N·m peak and 0.8 N·m continuous at the joint, and its driver has to survive 4 A of stall current, not the running amperes.

Why can't the 1-2 A reading size the actuator? #

Current is not a mechanical specification: the same 2 A becomes 0.8 N·m at the joint behind a 0.02 N·m/A torque constant and a 20:1 gearbox, and 5 N·m behind 0.05 N·m/A and 50:1, before gearbox losses. Torque reaches the joint as current times the torque constant, multiplied by the gear ratio and eroded by its efficiency, so one supply reading cannot say what the link sees. A battery-side figure also includes the logic, the encoder and any second axis on the robot. What the winding actually draws under a PWM bridge depends on duty cycle, supply voltage and back-EMF; DC brushed motor current draw under PWM control works through exactly that relationship. The 1-2 A reading earns one place in the design: confirming that running current stays inside the driver's continuous rating.

What must the joint deliver before you choose? #

Measure four things at the output shaft: peak torque including acceleration in N·m, continuous holding torque in N·m, peak joint speed in rad/s or rpm, and the commanded travel in degrees; this joint's travel requirement is the full 270 degrees, so every candidate must command that range. Then measure, do not infer:

  • Gravity torque T_g = m·g·r, with m the link mass, g = 9.81 m/s², and r the distance from the joint axis to the link's center of mass.
  • Inertia about the axis I = m·r² for a concentrated mass, plus motor and gearbox inertias reflected through the ratio squared.
  • For a triangular velocity profile, α = 4θ/t² and peak speed ω = 2θ/t, with θ the move in radians and t the move time.
  • Peak joint torque T_peak = I·α + T_g + T_friction; holding torque is T_g + T_friction.
  • At the motor, divide by gear ratio times efficiency, then convert to current with I = T/Kt.

Gravity torque can be measured directly: pull the link at a right angle with a spring scale at a known lever arm and multiply force by arm, and the force that just starts motion gives friction the same way. The reduction ratio is the same trade for any motor type, and sizing BLDC torque and reduction for a robot arm joint works it end to end. Holding decides the thermal question: if the joint must hold against gravity while stationary, that torque becomes continuous winding current, or it is offloaded to a counterbalance or a brake — what a servo motor holding brake does and does not do separates the static hold a brake gives from the moving load it does not stop.

How do the numbers work out for a forearm joint? #

For a 0.5 kg forearm with its center of mass 0.15 m from the axis, moving 90 degrees in 0.5 s, the joint needs 1.07 N·m peak and 0.79 N·m continuous — calculated example values for the inputs below, not catalog ratings or a measured result. The remaining inputs: friction 0.05 N·m, a 50:1 gearbox at 70 percent efficiency, motor torque constant 0.030 N·m/A, winding resistance 3 Ω, supply 12 V.

  1. Inertia: I = 0.5 kg × (0.15 m)² = 0.0113 kg·m²
  2. Acceleration: α = 4 × 1.571 rad / (0.5 s)² = 25.1 rad/s²
  3. Acceleration torque: 0.0113 kg·m² × 25.1 rad/s² = 0.28 N·m
  4. Gravity torque: 0.5 kg × 9.81 m/s² × 0.15 m = 0.74 N·m
  5. Peak joint torque: 0.28 + 0.74 + 0.05 = 1.07 N·m; holding: 0.74 + 0.05 = 0.79 N·m
  6. Peak joint speed: ω = 2 × 1.571 rad / 0.5 s = 6.28 rad/s = 60 rpm; motor side: 60 × 50 = 3000 rpm
  7. Motor peak torque: 1.07 N·m / (50 × 0.7) = 0.031 N·m; motor holding torque: 0.79 / 35 = 0.023 N·m
  8. Currents: 0.031 N·m / 0.030 N·m/A = 1.0 A peak; 0.023 N·m / 0.030 N·m/A = 0.75 A holding
  9. Holding heat: (0.75 A)² × 3 Ω = 1.7 W continuous
  10. Stall current at full voltage: 12 V / 3 Ω = 4 A

Converting a required motor torque into amperes is the one-step division servo sizing uses; how to calculate servo motor current from required torque shows the same arithmetic. Doubling the arm length doubles gravity torque and quadruples inertia; halving the move time quadruples acceleration torque. Gravity and speed dominate this joint, which is typical for a forearm.

Requirement at the joint Integrated positional servo Brushed DC + gearbox + H-bridge
Commanded travel At least 270 degrees, from the datasheet range Any travel; 270 degrees is a software limit
Peak torque At least 1.1 N·m at the servo output 0.031 N·m at the motor, behind 50:1 at 0.7 efficiency
Continuous torque At least 0.8 N·m at the servo output 0.023 N·m at the motor; 0.75 A holds hot
Speed At least 60 rpm at the output 3000 rpm at the motor
Feedback Internal; absolute across travel or homed at startup Your optical encoder; 0.007 degrees per count at 50:1
Drive electronics Nothing to design H-bridge above the 4 A stall, at 12 V
Effort Configuration Gearbox, encoder mount, limits, PID

Decision for the example: any actuator that delivers at least 1.1 N·m peak and 0.8 N·m continuous at the joint, turns it at least 60 rpm and commands the full 270 degrees qualifies. Behind the 50:1 gearbox that is a motor rated at least 0.031 N·m peak, 0.023 N·m continuous and 3000 rpm at its own shaft. The calculated 1.0 A running current lands inside the reported 1-2 A, which shows exactly why that reading could not have selected anything: a weaker motor geared differently draws the same amperes and stalls.

Does a positional servo cover a 270 degree joint? #

Yes, when three datasheet numbers pass: commanded travel of at least 270 degrees at the output, peak torque at or above the joint's peak, and continuous torque at or above the holding value — for the example joint that means 270 degrees, 1.1 N·m and 0.8 N·m. Read the controllable range, not the mechanical free play: many positional servos command less than the 270 degrees this joint needs, and the datasheet's travel line is the one that counts. Verify the command-to-angle mapping, because a pulse-width command encodes the angle in pulse timing and is not the PWM duty cycle that drives a bare motor; add the behavior at both endpoints, whether the internal feedback is absolute across the travel or needs a startup reference, and the supply voltage. The torque ratings sit at the servo's own output with its internal gearing included, so they compare directly against the joint numbers.

Decision: if the datasheet clears the travel, peak torque, continuous torque and speed from the example, take the servo and skip the driver design entirely. If travel or torque falls short, the brushed DC branch below is the build.

Does brushed DC with an H-bridge and a PID loop work? #

Yes: continuous rotation is the advantage, because the 270 degree limit becomes a software limit on an encoder that keeps counting, and the branch works once the gearbox maps the joint's 60 rpm to the motor's speed and the PID closes on a correctly scaled encoder. The gearbox multiplies torque and divides speed; the table above carries the example's 50:1 arithmetic. Scale the feedback before anything else: a 1024 count per revolution optical encoder on the motor shaft reads 51,200 counts per joint revolution through the 50:1 gearbox, which is 0.007 degrees per count and 38,400 counts across the 270 degree span — resolution that backlash, not counting, will dominate. Backlash and shaft compliance sit outside a motor-shaft encoder: the controller can report a perfect motor angle while the link sags under load, so put the encoder on the joint side when the position tolerance demands it. The encoder rides on the motor's tail shaft through a flexible shaft coupling sized to both shaft diameters, which absorbs the small misalignment between the two bearings. An incremental encoder needs a startup reference before absolute angles mean anything, and the direction sign must be proven before any gain is touched.

Close the loop as a position PID whose output commands torque through the bridge. Structuring it around a faster measured inner current loop is cascade control, and the case for that structure — a fast, measured inner process inside a slower outer loop — is made in cascade control around a fast measured inner process. Software limits at both ends of the 270 degree span belong in the controller, not in the hope that the loop never overshoots.

What does the H-bridge have to survive? #

Size the H-bridge on the motor's stall current, not the running current: the example motor draws about 4 A locked at 12 V (12 V / 3 Ω), so the driver needs a continuous rating above that stall figure and the 1-2 A running reading sizes nothing. Three checks, all from the motor and driver datasheets:

  • Voltage: the bridge's operating range covers the supply, 12 V in the example.
  • Current: continuous and peak ratings cover the 4 A stall; the 1.0 A running figure is the thermal case, not the sizing case.
  • Energy: deceleration and reversal push mechanical energy back into the supply; watch the supply voltage during a loaded reversal and confirm the driver's braking behavior before trusting it.

The current reading also has a hardware nuance: on the L298, for instance, the sense terminal is provided to allow measurement of current, not to limit it, and current limiting is a separate function a given driver may or may not implement. The driver's documentation says which it is; because a position loop that cannot reach its target holds the motor at stall current indefinitely, working current limiting is a thermal necessity, not an optional feature. Direction, brake and coast behaviors come from the same document and decide what the loop can actually command.

Decision: pick the driver from the stall current and the supply voltage — above 4 A continuous at 12 V for the example — and treat the running current as a thermal check on the motor and the bridge together.

How many poles should the motor have? #

Pole count is not a selection criterion for this joint: a brushed motor commutates mechanically through its brushes, so you select continuous and peak torque, speed, voltage and thermal rating, and the poles are whatever the motor's design gives you. Pole count decides step angle on a stepper and commutation phases on a brushless servo, so it matters when matching a motor to a drive, not when sizing torque for a joint. An integrated servo hides its poles behind the case and hands you torque, speed and resolution anyway.

Decision: size the joint from the torque-speed curve and the thermal rating, and leave pole count out of this selection entirely.

How do you prove the axis before it runs free? #

Commission with the joint restrained and a current-limited supply: verify encoder direction on a known 90 degree move, set the software limits to the measured 270 degree span, then close the PID at low gain and confirm the current limit before any free motion.

  1. Restrain the link and power the axis from a supply you can limit.
  2. Command a known 90 degree move and compare commanded change against counted change; fix scale and direction before any gain.
  3. Set the software travel limits to the measured 270 degree span, with margin to the mechanical stops.
  4. Close the PID at low gain and raise it until tracking is acceptable without buzzing at setpoint.
  5. Command a move into a deliberate restraint and confirm the current limit acts at its documented value.
  6. Repeat the full travel and re-check the zero; drift points to encoder signal integrity, not gain.

Keep the travel arc clear and the link restrained until direction, limits and the current limit are proven: an unstable loop drives the arm into its stops at full stall current.

Final decision: if a positional servo's datasheet clears the travel, torque and speed numbers of the example, use it and skip the driver design; otherwise build the geared brushed DC branch, with the H-bridge sized to the stall current and the encoder scaled and homed before the PID is tuned.

Questions asked

How do I measure joint torque without a torque sensor?

Pull the link at a right angle with a handheld spring scale at a measured lever arm from the joint axis, and multiply force by arm length to get torque in N·m. Take the reading that just starts the motion as friction. The scale and the arm are the only instruments needed, and the method agrees with the gravity formula in the article.

What holds the arm when power is off?

A brushed DC joint holds unpowered only if the gearbox is self-locking, which conventional spur stages are not; a worm stage can be. Otherwise the arm falls to its stop. The powered hold is continuous winding current, so the realistic options are a counterbalance spring, a self-locking worm stage, or a brake sized for the static load.

Is an incremental optical encoder enough for position?

Yes, with a reference move at every startup, because an incremental encoder loses its absolute angle at power-off. Home against a known stop or a switch, approach slowly, and treat the counted travel across the 270 degree span as valid only after that reference. Retest the zero after long sessions, since lost counts show up as slow position drift.

Can I estimate joint torque from motor current instead?

Multiply measured current by the torque constant to estimate motor torque, then divide by gear ratio times efficiency for the joint. It is an estimate: gearbox friction and efficiency vary with speed and load, so the figure is least trustworthy exactly where a joint lives — low speed, holding, and near stall. Use it to sanity-check the scale measurement, not to replace it.

Does PWM frequency matter for this joint?

It shapes audible noise and current ripple in the winding, not the position logic. Run inside the driver's documented frequency range, high enough that the joint is quiet, and expect the current reading to shift slightly when you change it. The exact value and its limits come from the driver datasheet, and nothing in the PID tuning depends on it.

Keep reading

  • How-to

    Correcting Rack and Pinion Speed and Torque for a Gantry Retrofit

    Travel per pinion revolution is πN/DP inches, not the pitch diameter. With an 8:1 reduction and a 22-tooth DP 16 pinion, 500 ipm needs about 926 rpm per gantry motor; the DP 20 carriage at 128/22 needs about 842 rpm. Size acceleration torque from moving weight, pinion radius, reduction and efficiency before buying drives.

    Motors, gearboxes and drives sizing

  • Selection guide

    Resolver feedback servo selection for small 0.7 kW axes

    A resolver requirement gates servo selection on feedback hardware, not on power rating. Confirm the exact drive hardware takes the resolver natively, size each 0.7 kW axis from its motion cycle instead of the kilowatt label, then choose between one resolver-capable multi-axis system and separate single-axis drives. An oversized frame is a fallback, not the default.

    Motors, gearboxes and drives sizing

  • Explainer

    Servo kg cm torque rating: what it really says about payload

    A servo sold as 35 kg is usually a stall torque of 35 kgf·cm, about 3.43 N·m at the output shaft — not a 35 kg payload. Payload comes from the gravity torque at each joint: mass times gravity times reach, plus acceleration torque, compared with the rating.

    Motors, gearboxes and drives sizing