Troubleshooting
Why a servo in torque mode kicks the wrong way at reversal
Short answer
A servo drive that reverses cleanly in velocity mode but makes torque the wrong way for about 100 ms after the analog torque reference changes sign is faulted in its torque-mode reversal path: motor-lead swaps and the CW/CCW direction setting cannot remove a transient generated after the reference stage. Capture the trace, run the three-configuration test, then replace the drive and send the trace and parameter set to the supplier.

On this page
If your servo drive reverses cleanly in velocity mode but makes torque in the wrong direction for about 100 ms each time the ±10 V analog torque reference changes sign — and neither a motor-lead swap nor the setting that maps a positive command to CW or CCW changes anything — the fault sits in the drive's torque-mode reversal path, downstream of the reference stage. That means the drive, not your controller, your wiring or your phase order. The sequence below proves it in one session: capture the trace, repeat in velocity mode, flip the direction setting, swap the leads, then run a second drive on the same outputs. When the kick survives all of that, replace the drive and send the trace and parameter set to the supplier.
What the reversal trace shows #
Your pattern, from the captured transitions:
- Positive reference: torque develops in the expected direction.
- Zero reference: torque ceases.
- Sign change: the current and the feedback swing the wrong way for about 100 ms, then turn and continue correctly.
- The kick appears at higher command magnitudes too, with no external servo loop active.
In torque control mode the drive maps the analog reference voltage straight to a torque command, and a parameter sets the maximum torque the full-scale voltage stands for — the same direct path behind torque mode DAC voltage capped with load cell feedback. Your trace localizes the fault past that mapping. Positive commands work, zero commands correctly produce nothing — the healthy zero behavior, unlike the case in stopping continuous rotation servo creep at zero command — and both signs eventually settle correctly.
A scaling or offset error would shrink or shift the torque; it cannot invert the sign for an interval and then recover. What can is the sign handoff between the reference processing and the current loop at the transition through zero. Because the feedback channel moves with the current, the shaft physically turns backward: real motion, not a plotting artifact. Everything below applies once your own trace shows this same pattern.
Likely causes, cheapest first #
- The reference itself glitches at the transition. Confirming check: scope the analog input at the drive's terminals during a sign change. The faster version is the result you already have — the same controller outputs drove a different drive and motor correctly in torque mode, which clears the controller.
- The direction configuration: the parameter that sets whether a positive command means CW or CCW, plus direction selection through a drive input. Confirming check: flip the parameter and re-run; the kick keeps its timing relative to the command sign change, so the setting is not the cause.
- Motor phase order. Confirming check: swap the motor power leads following the manual's reversal procedure; the kick follows the command sign rather than the physical rotation direction, so the leads are not the cause either.
- The mains terminals. Not a cheap check — the fault is mode-selective and the experiment carries real risk, so the section below closes it out instead.
- The drive's own torque-mode reversal handling: reference processing, the current-loop sign handoff, or a defective unit. Confirming check: a second drive on the same outputs with the same parameter file — the last and most decisive step below.
The test sequence that localizes the fault #
- Turn the torque-limit parameter down before anything moves, and unload or block the axis: in torque mode no position loop restrains the load, and the kick will move it.
- Connect the manufacturer's tuning package and put the analog input, the motor current and the feedback in one trace.
- Step the reference positive, zero, negative, zero, positive, dwelling at each level; the worked example below times it.
- Repeat in velocity mode on the same wiring. A clean reversal confines the fault to the torque path.
- Repeat in torque mode with the direction parameter flipped, then with direction selected from the drive's external input.
- Swap the motor power leads and repeat.
- Mount a second drive on the same controller outputs, load the saved parameter file, and repeat.
- Save the parameter set and the trace that shows the kick; both go to the supplier with the unit.
If the tuning package connects but crashes before you get the trace, the section below covers that first.
Timing the wrong-direction kick on a ±10 V reversal test #
The inputs, all from your own case:
- Analog torque reference: ±10 V, your controller's output.
- Wrong-sign interval: about 100 ms in your capture, measured from the reference sign change to the current's first correct-sign sample.
- Command levels per cycle: positive, zero, negative, zero — your test pattern.
- Dwell rule: ten times the expected interval. That is a rule of thumb, chosen so the kick is a small slice of each capture with steady behavior visible on both sides.
The rule in words: hold each level for ten times the wrong-sign interval, run the four-level cycle in each configuration, and add one velocity-mode cycle as the control.
The arithmetic:
- Reference swing: 10 V − (−10 V) = 20 V.
- Dwell per level: 10 × 100 ms = 1000 ms = 1 s.
- One cycle: 4 levels × 1 s = 4 s.
- Three torque-mode configurations — as found, direction setting flipped, leads swapped: 3 × 4 s = 12 s.
- Plus the velocity control cycle: 12 s + 4 s = 16 s of trace in total.
Result: sixteen seconds of trace covers the whole diagnosis, and in your captures the wrong-sign interval reads the same in every torque-mode run while the velocity run reverses cleanly.
Decision: an interval that holds at that value through the direction flip and the lead swap, with velocity mode clean, means the transient is generated inside the drive's torque path — replace the drive. A healthy reversal brings the current to the commanded sign within the current loop's own response time, a few milliseconds; if one of your changes collapses the interval to that, the change you just made was the fix.
Why R and S is the wrong experiment #
Your drive's manual designates R and T for the single-phase supply. The same discipline runs through single-phase-capable drive families generally: verify R, S, T and L1, L2 against the wiring chapter before power-up, and feed the single-phase 230 V only to the pair the manual names. Three reasons to close the mains question without experimenting:
- The fault is mode-selective. The rectifier and the DC bus sit upstream of the control-mode selection, so a mains-terminal error would corrupt velocity mode too — and velocity mode reverses cleanly.
- The one-leg current reading is the software reporting one selected phase or estimate, not evidence about the power stage; the inverter of a working drive commutates all three motor phases.
- Landing mains on undocumented terminals risks the input stage for no diagnostic gain.
Check that R and T are wired as the manual says, confirm the drive powers up normally, and move on.
Getting the trace off the tuning software #
The manufacturer's tuning package talks to the drive over its serial port, and a USB-to-RS-232 converter stands in where the machine has no serial port of its own. One reported case: the link established, but reading parameters or starting a test run crashed the package under the current desktop operating system, no baud-rate change helped, and the same serial settings ran on the older operating-system generations the package was written for. If your package connects and then crashes, run it on an older machine before blaming the drive, and take the software only from the manufacturer or its distributor. You need that trace; without it the supplier has nothing to analyze.
The decision for each outcome #
- Kick in torque mode only, unchanged by the direction flip and the lead swap, clean in velocity mode, gone on the second drive with the same parameter file: the first drive's torque-mode path is defective. Replace it and send the saved parameter set and trace with the unit.
- Kick on the second drive too: the source is your reference. Scope the controller output at the drive's input terminals during the transition and fix it on the controller side.
- Kick gone after the direction flip or the lead swap: it was configuration or phase order. Record which change cleared it and re-verify with the same four-level cycle.
- R and T confirmed as the manual specifies: the mains are cleared; leave R and S alone.
Questions asked
Can I close my own position loop around torque mode and let it absorb the kick?
A loop can only fight the kick after the axis has already moved, and how well it recovers depends on your gains and the travel you can spare. That turns a hardware fault into a permanent tuning burden, so replace the drive first and tune the loop on hardware that reverses correctly.
Should I update the drive firmware to fix the reversal?
Only with firmware the manufacturer or its distributor issues for your exact drive version, installed by its documented procedure; an image from anywhere else can disable the drive and ends vendor support. Ask the supplier whether a documented update addresses torque-mode reversal, and send the saved parameter file and trace with that question.
Why does the current display show only one leg with current?
Because the package reports whichever single phase or internal estimate it is set to show; one nonzero leg reading is a display choice, not evidence about the power stage. A drive actually missing an output phase would run badly in every mode, while here velocity mode reverses cleanly, which is one more reason the mains terminals are not worth experimenting with.
Is the wrong-direction kick hard on the mechanics?
The impulse the load sees scales with the torque limit and the length of the kick, so at full torque on a high-inertia load the reversal hammers the coupling and takes up gearbox backlash the wrong way. Turning the torque-limit parameter down before testing bounds the worst case; run repeated tests unloaded.