Explainer
What 2 KG/CM on an Old DC Servo Means for a Spindle
Short answer
A nameplate marked 2 KG/CM means 2 kgf·cm of shaft torque: 0.196 N·m, about 28 ozf·in — not 180. The motor's own numbers agree: its rated output and speed work back to 0.191 N·m. That rating fits light axis drives, and a small-mill spindle only for light cuts whose torque and power both stay under the reduced torque and the rated output; for real spindle duty, a used three-phase AC motor with a VFD is the better machine.

On this page
That 2 KG/CM on the nameplate is about 0.196 N·m of shaft torque — roughly 28 ozf·in, not the 180 oz·in a hasty conversion produces. The motor's own nameplate confirms the small number: rated output divided by rated speed lands within rounding of the converted torque. That rating puts the motor in axis-drive territory: at home as a light axis drive, and viable as a benchtop-mill spindle only for light cuts where the torque needed at your spindle speed after belt reduction and the power the cut consumes both stay inside what the nameplate allows. For spindle duty beyond that, a small three-phase AC motor with a VFD is usually the better machine. Here is the reading, the cross-check from the nameplate itself, and the decision for each use.
What the marking 2 KG/CM means #
Torque is force multiplied by arm length — the slash in KG/CM is not a division. Older metric motor plates print torque in kilogram-force centimeters: the pull of gravity on a kilogram of mass, acting on a one-centimeter arm. The SI unit is the newton-meter; kilogram-force is a legacy gravity-metric unit, but the conversion between the two is exact.
Carry the force and the arm separately. One kilogram-force is 9.80665 newtons and one centimeter is a hundredth of a meter, so one kgf·cm is 0.0980665 N·m, and the marking converts to 0.196 N·m. In the unit most small-motor listings use, one kgf·cm is 13.89 ozf·in, so the marking is 27.8 ozf·in — call it 28. Before you compare that figure with motor listings, see what an oz-in rating measures.
The 180 figure comes from flipping the length conversion. Two kilogram-force pulls about 70.5 ozf, and multiplying that by 2.54 centimeters per inch instead of dividing gives 179 — the 180 oz·in that gets passed around. Divide by 2.54 instead and you get the correct 27.8. One reading is six and a half times the other, and which one you believe decides whether this motor is ever a spindle candidate.
Why strong torque at 12 V is not a spindle rating #
A brushed permanent-magnet DC motor makes shaft torque in proportion to armature current, and its winding heats with the square of that current. At or near standstill the mechanical output is zero: the twist you feel with 12 V on the terminals is torque at zero power, and held there it is heat with no work done. A spindle needs torque at speed, which is power, so the bench test answers a different question than the mill asks.
When the assembled motor later sags or stalls in a cut, read three things under the same load change: shaft speed, armature current, and the voltage arriving at the motor terminals. Speed falling while current rises points at the torque limit; voltage sagging points at the supply; current clamped at a flat ceiling points at the drive's limit setting. How to calculate servo motor current from required torque is the conversion that turns a measured current into the torque that cut was demanding.
What sets the supply voltage #
The three nameplate lines — output, speed, torque — do not state a rated voltage, so no supply choice, 36 V included, can be confirmed or rejected from them. The motor's documentation can, so get it from the manufacturer or an authorized channel, and photograph every plate and connector marking before wiring anything. On robot servos, power, feedback, brake and temperature leads often share one connector, and wire count alone does not assign terminals.
For a motor you have confirmed is a brushed permanent-magnet DC type, speed follows applied voltage approximately, because terminal voltage splits between the resistance drop and the back-EMF, which rises with speed. A current-limited no-load run at low voltage, with speed measured, gives a rough volts-per-speed slope. Use the slope to sanity-check a supply candidate — if it carries your supply voltage past the rated speed, that supply is too hot as a starting point — but never to declare a rating: brush and bearing friction bend the line, and the rated speed is an operating point, not a declared overspeed limit.
When you pick the drive, carry the documented ratings across: replacing drives on old DC servo motors without sizing errors lists the figures that must move from motor to drive, so the limits are set from the motor rather than from hope.
Before any energized test, restrain the motor and guard the shaft, and stop at rough rotation, abnormal noise or fast heating.
Reduction raises spindle torque, never power #
With a belt or gear ratio between motor and spindle, spindle speed is the motor speed divided by the ratio, and spindle torque is roughly motor torque times the ratio, times the transmission efficiency. The load's inertia arrives at the motor divided by the ratio squared, which flatters acceleration but adds nothing to continuous cutting power. Power at the cutter equals the motor's output times the transmission efficiency, so the rated output — not the ratio — is the ceiling. A reduction can make the torque arithmetic look comfortable while the cut still starves for power, so check torque and power against the cut separately.
Honor the mundane limits before mounting: belt tension and alignment, and the radial shaft load the motor's documentation permits.
If the reduction is a belt drive, you set the ratio through the tooth counts of the two timing pulleys you choose, one on the motor shaft and one on the spindle.
Worked example: 2 KG/CM on an 80 W, 4000 rpm nameplate #
Inputs, each from the nameplate or the machine plan:
- Torque marking: 2 KG/CM, read as kilogram-force centimeters (nameplate)
- Rated output: 80 W (nameplate)
- Rated speed: 4000 rpm (nameplate)
- Belt reduction: 2:1, giving a 2000 rpm spindle (an example ratio for small end mills on a benchtop mill)
The rules, in words: convert kgf·cm to newton-meters by multiplying by 0.0980665, and to ounce-force inches by multiplying by 13.89. Cross-check the reading with the nameplate's own power line: rated torque equals rated output divided by angular speed, where angular speed in rad/s is 2π × rpm ÷ 60. Through a reduction, before losses: spindle torque equals motor torque times the ratio, and spindle speed equals motor speed divided by the ratio.
The arithmetic:
- 2 kgf·cm × 0.0980665 = 0.196 N·m
- 2 kgf·cm × 13.89 = 27.8 ozf·in
- Angular speed: 2π × 4000 ÷ 60 = 418.9 rad/s
- Power check: 80 W ÷ 418.9 rad/s = 0.191 N·m, within rounding of the converted 0.196 N·m — the kgf·cm reading is the consistent one
- Wrong reading: 180 ozf·in ÷ 141.6 = 1.27 N·m, and 1.27 N·m × 418.9 rad/s = 532 W, more than six times the rated output. A motor with this output cannot deliver that, so 180 is the wrong unit reading.
- Spindle: 4000 rpm ÷ 2 = 2000 rpm, and 0.191 N·m × 2 = 0.382 N·m (about 54 ozf·in) at the spindle before belt losses
Result: the nameplate describes roughly 0.19 to 0.20 N·m of rated shaft torque — about 28 ozf·in — and the example spindle sees 0.382 N·m at 2000 rpm before losses, under the rated-output power ceiling. These are calculated nameplate figures for these inputs, not measured cutting results.
Decision, with the thresholds: this motor holds spindle duty only while both lines hold — the cut's torque demand at your spindle speed stays under the reduced torque figure, scaled to your actual ratio, and the cut's power demand stays under the rated output, with belt losses shaving both. If either line fails, the motor's job changes from spindle to axis.
The decision for each use #
As an axis drive: yes. With a belt reduction sized from the axis speed and force, a motor of this class is at home on a light benchtop axis — the same reasoning that puts belt reduction on small stepper axes instead of direct drive. Its rated output is about 0.11 hp, which moves a small table or carriage briskly in rapid travel.
As a spindle motor: only for the light duty that fits the two thresholds above — shallow cuts in soft material on a small machine, with the ratio chosen so cutting speed lands where the tool wants it. Beyond that duty, plan the spindle around a small three-phase AC motor with a VFD: the drive holds speed under load across the speed band, there are no brushes to service, and secondhand units are the usual route on rebuilt benchtop machines. Keep the robot servo for an axis.
Decision in one line: axis drive — yes, with reduction. Spindle — only if the cut's torque and power both fit under the worked example's thresholds; otherwise the used AC motor and VFD is the better machine.
Questions asked
Does the KG in the marking mean kilograms or kilogram-force?
Kilogram-force. Torque needs a force, and a kilogram is a mass; kilogram-force is the pull gravity exerts on one kilogram, about 9.80665 newtons. Older metric motor nameplates often print it simply as KG, so a marking reading 2 KG/CM is 2 kgf·cm. That is why the conversion to newton-meters runs through 9.80665 before the centimeter arm is applied.
What belt ratio suits a small mill spindle running from 4000 rpm?
Start from the cutting speed your tool wants, not from the motor. Spindle rpm equals surface speed in feet per minute, times 12, divided by pi times the tool diameter in inches; the belt ratio is the motor's rated speed divided by that spindle speed. Small end mills in aluminum usually want speeds far below the rated speed, so as a rule of thumb a single-stage ratio near 2 to 1 is a starting point, verified with a trial cut.
Can the robot's original controller box run these motors?
Not until its wiring is identified from documentation for that controller. Wire count alone does not assign terminals: power, feedback, brake and temperature leads can sit in one connector, and the controller expects the feedback devices the robot used. Until the motor's rated voltage, current and feedback type are documented, match the motor to a drive whose limits you can set from those documented ratings.
How do I check the torque my mill cuts actually need?
Measure it on the machine you have. Run a trial cut with the present spindle and log armature current or the drive's load indication through the cut. Convert that current to torque with the motor's torque constant from its documentation, then compare the result against the torque available at your planned spindle speed after reduction. If a light trial cut already sits near the continuous rating, the motor is out of spindle duty.
Is a brush-type DC motor a sensible spindle motor to begin with?
For intermittent work it can be, but brushes are the catch: a spindle runs long continuous duty, so brush wear becomes routine service, brush dust lands near the work, and commutation limits the top speed. A small three-phase AC motor with a VFD holds speed under load with no brushes to service, which is why it is the usual spindle choice on rebuilt benchtop machines.