Motion Library
Earlier articles

Explainer
What servo oscillation without a controller requires
No. A hobby positional servo cannot oscillate on a constant supply alone: with nothing changing on its signal wire it holds the position the last command pulse described. Automatic back-and-forth needs a source of changing pulses, and the cheapest one is a small Arduino-class board sharing ground with the servo and powering the servo separately at its stall current.

Troubleshooting
Servo Motor Torque Below Datasheet: Measure Before You Change
Measure loaded terminal voltage and output torque at a known arm radius before changing anything. A lower supply voltage than the rating cuts stall torque, commanding more travel adds none, and a longer output arm raises the torque required for the same force. Most shortfalls are electrical, mechanical or geometric, not a weak command.

Explainer
Writing an external encoder gear ratio: what persists, what activates
Save the gear ratio with MC_BR_ProcessConfig and the mcCFG_ACP_EXT_ENC_AX_MECH_ELM datatype and it survives a restart but activates only at that restart. Write it with MC_BR_ProcessParam and it works immediately but is lost at restart. Save first, then load the saved configuration with mcPPM_LOAD_FROM_CONFIG to get both, and set the datatype to the external-encoder mechanical elements, not the real-axis ones.

Troubleshooting
Why a 2 DOF Robot Arm Curves Near the End of a Straight Line
The curve near the end of the stroke is almost always the inverse kinematics, not the servos: the cosine-law solver flips between the elbow-up and elbow-down branch because the sign of the square-root term s2 is not fixed. Hold one branch for the whole stroke, take both angles from atan2, and require c2 to stay between -1 and 1 at every waypoint. Confirm it by plotting the forward-kinematics path of the commanded angles before touching the update rate.

Selection guide
What an EtherCAT Label Actually Tells You About a Servo Drive
An EtherCAT label proves only that a servo drive can join the network. Judge the implementation by a documented CiA 402 or IEC 61800-7-201 drive profile, distributed-clock synchronization at your cycle time, clean state transitions to an enabled axis and measured motion under load; a good implementation goes from ESI import and bus scan to a moving axis in one session, while a poor one costs weeks of startup-parameter debugging.

How-to
Mounting a concentrated mass on a robot arm link
Treat a 3 to 4 kg attachment bolted to a robot arm link as a link load-model change, not a bigger tool payload: it adds 29 to 39 N and a gravity moment equal to weight times the perpendicular lever arm, which changes with pose. Weigh the complete assembly, find its center of mass and lever arms, keep the bulk feeder on an external support, and take the numbers to the robot manufacturer before any link mount runs.

Explainer
Why ISA-5.1 has no pneumatic speed controller symbol
No ISA-5.1 symbol exists for a pneumatic speed controller, and none is missing: ISA-5.1 defines instrument functions, not fluid power hardware. Draw the throttle-and-check unit from ISO 1219 symbols or copy the supplier's catalog symbol for the exact part, define it in the project legend, point the check valve's free-flow arrow for meter-out or meter-in, and mount it at the actuator port.

Explainer
Why differential stepper drive inputs map straight to axis outputs
The CW+/CW-/CCW+/CCW- terminal set is two opto-isolated inputs: the CW pair carries step pulses and the CCW pair carries direction, and each is just an optocoupler LED that responds to current, not to wiring style. A differential controller therefore wires straight across, S+ to CW+, S- to CW-, D+ to CCW+, D- to CCW-, with no receiver module; the old common feed belonged to the old controller's single-ended outputs, not to the drive.

Explainer
Why an Enabled Servo Axis Corrects Position After the Move
The correction after a completed move is the enabled position loop removing an error that an external load created. Stop it by removing servo action for that window only, with Motion Servo Off before the sealing jaws close and Motion Servo On before they open, then prove the window with the ServoActionStatus and DriveEnableStatus trends.

Troubleshooting
Why a pre-armed capture flag does not end a homing search
Arming a gated capture with CaptCtrl=0 sets the flag at write time, but the ACC-24E3 homing startup reads the captured-position register, clears that flag and waits for a new edge-triggered event that never arrives. Complete the command with CaptureMode=2 and WarnFeLimit=0.001 counts, or skip the search on absolute axes with homez and a calibrated HomeOffset.

Comparison
Cut-to-length servo feed: which control architecture fits
Use the PLC's built-in pulse output as a relative move: each cycle the program multiplies the typed length by the motor revolutions per millimetre of travel and the drive's command pulses per revolution, sends that count to the drive, and releases the cutter on motion-complete. Stored-position drives fit fixed move sets, and a position-control card only pays off past the CPU's built-in axis count.

Troubleshooting
Why a Vertical Z Axis Back-Drives With Servo Power Off
A vertical Z axis that drops with servo power off is back-driving its mechanical drive, not losing a control setting. Find and restore the mechanical holding path — in one retrofit the fault was an extremely loose motor-mount belt tensioner — before fitting a brake or counterbalance. A regeneration resistor is never holding hardware, and tuning fixes powered motion only.