Motion Library
Earlier articles

Selection guide
Electro-pneumatic pressure transducer selection for a 0-10 V command
A voltage command that must produce a proportional pressure output calls for an E/P transducer, the voltage-input version of an I/P device. Select it by input signal type, pressure span, flow capacity against the real actuator volume, response time, and documented loss-of-power behavior, then prove the loaded pressure before trusting it in a brake or safety-related circuit.

Explainer
How an incremental encoder shows direction of rotation
An incremental encoder carries direction in the order of its A and B edges, not in their frequency: in quadrature, A leads B by 90 electrical degrees in one rotation direction and B leads A in the other. A quadrature-capable counter resolves that edge order into a signed count; a single channel or a slowly scanned input cannot.

Explainer
Why per-product conveyor speed changes at the handoff, not the batch
Trigger each conveyor's speed change from a photoelectric sensor at its own inlet, where the belt takes the box over, instead of from the feeder's batch change: 2.4 m/min for box type 1, 1.2 m/min for box type 2. Three conveyors of different length then switch at three different moments, as the new batch front reaches each one, and stay fully independent.

Explainer
Alternator frequency control of a hydraulic proportional valve
A hydraulic-motor-driven alternator is a speed sensor: output frequency in hertz equals rpm times pole count divided by 120. Convert that frequency to a DC command with a 555 timer or a CD4046 phase-locked loop against a quartz reference, filter it, amplify the error, and drive the proportional valve with current. The loop holds flow constant while a PTO pump's speed follows the road.

Comparison
AC vs DC Servo Motors: What Actually Differs
A brushed DC servo commutates itself, so torque follows armature polarity and the amplifier only has to control the size and direction of one current. An AC or brushless servo needs the drive to place phase currents against rotor-position feedback, so motor and drive must be selected as one matched system. The article gives the torque and back-EMF arithmetic and a decision for each case.

How-to
5-Phase Stepper Motor Winding Sequence from Ten Leads
Ten leads mean five separate windings you can find with an ohmmeter; the running order comes from the voltage each winding generates as you turn the shaft. Map without power, confirm with a current-limited step test, and never open the motor.

Explainer
Conveyor Trigger Capture Before Gantry Line Tracking
Capture the conveyor position once, at the fixture trigger, and gear the gantry X axis to the conveyor from that captured coordinate. Before any trigger arrives, compute the acquire-place-clear cycle against the remaining conveyor travel; when the margin falls below the conveyor's stopping distance plus the cycle advance, pause the conveyor instead of letting the gantry run out of travel.

Explainer
What a controller output switching rate does to stepper speed
Motor speed equals the step pulse frequency divided by the driver's increments per revolution, so the controller's maximum output switching rate sets the ceiling. A compact controller whose technical data lists 10 Hz commands ten increments each second — 1 mm/s of feed with 0.1 mm of travel per pulse. That suits slow indexing; anything faster needs a dedicated pulse output, not more reduction or microstepping.

Troubleshooting
Why Ballscrew Coupling Repair Shifts Absolute Encoder Home Position
Reassembling a ballscrew coupling at a new clocking angle moves the slide while a motor-side absolute encoder stays healthy, so the machine coordinate is wrong even though the feedback is fine. Prove the coupling cannot slip, compare the displayed coordinate with a documented datum approached from the normal direction, then re-establish the absolute reference there. A linear scale on the slide keeps its datum; do not re-zero it.

Explainer
Why a stepper pulse output reads about 12 VDC on a meter
A DC meter on a running pulse output reads the time-average of a 0 V to 24 V square wave, so at about 50% duty it shows near 12 V while the direction pin holds a true 24 VDC. The drive's 21.6 VDC minimum applies to each pulse's high level, verified with a scope, a frequency meter or the drive stepping correctly, not to the averaged reading.

Explainer
Why a VFD Cannot Run a Synchronous Servo Motor
A VFD in V/f or scalar mode cannot run a synchronous servo motor because it commands only voltage and frequency and has no rotor position input; torque in a permanent-magnet rotor depends on the torque angle, which collapses past 90 electrical degrees without closed-loop commutation. Wire the motor to a servo drive that reads its encoder instead — for the 1FK7 family, a SINAMICS S120 single-axis configuration with a CU310-2 control unit and a PM240-2 power module.

Explainer
What a servo to induction motor replacement needs on conveyors
Size an induction motor replacement by the measured load cycle and the synchronization requirement, not by nameplate power. Equal kilowatts do not guarantee equal starting torque, low-speed cooling or position sync, because an induction motor runs with slip and its shaft-mounted fan cools poorly at low speed.